ULTRASONIC COMPACT ENERGY METER
SHARKY 775
Meter with integrated OMS 3.0 868/434 MHz radio profile A or B and other flexible plug&play modules. Extremely economical and durable with battery life of up to 16 years. MID approved as heat and heating/cooling meter. Dynamic range up to 1:250
SHARKY 775
- Nominal size (qp)
- 0.6 ... 100 m³/h
- Nominal diameter (DN)
- 15 ... 100 mm
- Approval
- MID class 2
- Temperature range
- 5 ... 130 (150) °C
- Interfaces
- Radio / M-Bus / Pulse / MOD / RS232 ...
-
ULTRASONIC COMPACT ENERGY METER
SHARKY Solar 775
SHARKY Solar for Tyfocor LS glycol with integrated OMS 3.0 868/434 MHz radio and other flexible plug&play modules. Extremely economical and durable with battery life of up to 16 years.
SHARKY Solar 775
- Nominal size (qp)
- 1.5 ... 2.5 m³/h
- Nominal diameter (DN)
- 15 … 20 mm
- Approval
- none
- Temperature range
- 5 … 130 °C
- Interfaces
- Radio / M-Bus / Pulse / RS232 / RS485 …
-
ULTRASONIC COMPACT ENERGY METER
SHARKY 774 compact
Compact and economical meter for a 12-year lifespan with OMS 3.0 868 MHz or M-Bus integrated. Approved MID in heating or bifunctional (heating/cooling) version.
SHARKY 774 compact
- Nominal size (qp)
- 0.6 … 2.5 m³/h
- Nominal diameter (DN)
- 15 … 20 mm
- Approval
- MID class 2
- Temperature range
- 5 … 105 (130°C as option) °C
- Interfaces
- Radio / M-Bus
-
ULTRASONIC FLOW SENSOR
SHARKY FS 473
SHARKY FS is an ultrasonic flow sensor with pulse for any calculators. Economical and durable with external power supply or battery (life of up to 12 years). Approved as heat flow sensor in accordance with MI004, exists also for cooling applications.
SHARKY FS 473
- Nominal size (qp)
- 0.6 … 100 m³/h
- Nominal diameter (DN)
- 15 … 100 mm
- Approval
- MID class 2/3 PTB K 7.2 for cooling
- Temperature range
- 5 ... 150 °C
- Interfaces
- Pulse
-
ULTRASONIC FLOW SENSOR
SHARKY FUE 380
SHARKY FUE is an ultrasonic flow sensor with display and pulses for any calculators. Economical and durable with external power supply or battery (life of up to 6 years). Approved as heat flow sensor in accordance with MI004.
SHARKY FUE 380
- Nominal size (qp)
- 200 ... 1,500 m3/h
- Nominal diameter (DN)
- 125 ... 350 mm
- Approval
- MID MI004
- Temperature range
- +5...+120 / +200 °C
- Interfaces
- Pulse
-
MECHANICAL FLOW SENSOR
RAY FS WP MID
Robust mechanical WP flow meter with mechanical counter for heat measurement. The counter provides a pulse output for connection to external calculators.
RAY FS WP MID
- Nominal size (qp)
- 15 ... 200 m³/h
- Nominal diameter (DN)
- 50 ... 200 mm
- Approval (MID)
- Class 2 / 10:1 qp / qi
- Temperature
- 10 ... 120 °C
- Interfaces
- Pulse
-
MECHANICAL FLOW SENSOR
RAY FS WS MID
Robust mechanical WS flow meter with mechanical counter for heat measurement. The counter provides a pulse output for connection to external calculators.
RAY FS WS MID
- Nominal size (qp)
- 15 ... 150 m³/h
- Nominal diameter (DN)
- 50 ... 150 mm
- Approval (MID)
- Class 2 / 25:1 qp / qi
- Temperature range
- 15 ... 120 °C
- Interfaces
- Pulse
-
ELECTROMAGNETIC FLOW SENSOR
OPTIFLUX 4300
OPTIFLUX 4300 is an electromagnetic flow meter designed for measuring the flow of hot and cold water. Its electromagnetic technology gives it many advantages : no moving parts (no mechanical wear), high measuring dynamics, low pressure drop, low start-up flow and insensitivity to suspended particles.
OPTIFLUX 4300
- Nominal size (qp)
- 16 ... 2500 m3/h
- Nominal diameter (DN)
- 25 ... 300 mm
- Approval
- MID (DE-13-MI004-PTB005) only for water
- Temperature range
- 0 ... +140 °C
- Interface
- Pulse output | Analogue output
-
ENERGY CALCULATOR
SCYLAR INT 8
MID approved calculator used in heating and cooling applications. Scylar INT 8 with integrated OMS 3.0 radio and other flexible plug&play modules. Battery lifetime up to 16 years.
SCYLAR INT 8
- Volume pulse input
- 0.01 … 10,000 l/pulse
- Temperature sensor type
- Pt 100 or Pt 500 with 2- or 4-wire leads
- Approval
- MID (DE-10-MI004-PTB004)
- Temperature range
- 0 … +180 °C
- Interfaces
- Radio / M-Bus / Pulse / Modbus...
-
ELECTROMAGNETIC FLOW SENSOR
PROMAG
PROMAG is an electronic flowmeter designed for measuring heating water or any other type of conductive liquids (>50 µS/cm) used in air conditioning systems.
PROMAG
- Nominal size (qp)
- 9 ... 3,300 m3/h
- Nominal diameter (DN)
- 25 ... 500 mm
- Approval
- ACS | WRAS
- Temperature range
- -40 ... +130 °C
- Interface
- Pulse | Analogue output
-
ENERGY CALCULATOR
SCYLAR INT 8 Glycol version
MID approved calculator used in heating and cooling applications. Scylar INT 8 glycol version with integrated OMS 3.0 radio and other flexible plug&play modules. Battery lifetime up to 16 years.
SCYLAR INT 8 Glycol version
- Volume pulse input
- 0.01 … 10,000 l/pulse
- Temperature sensor type
- Pt 100 or Pt 500 with 2- or 4-wire leads
- Temperature range
- 0 … +180 °C
- Interfaces
- Radio / M-Bus / Pulse / Modbus...
-
INDUSTRIAL METER
VZO4 / VZO8
VZO is a volumetric meter with oscillating piston designed for fuel or mineral oil measurement. VZO may be fitted with a pulse emitter.
VZO4 / VZO8
- Nominal size (qp)
- 50 .. 135 l/h
- Nominal diameter (DN)
- 4 & 8 mm
- Temperature
- Up to 60 °C
- Interface
- Pulse
-
INDUSTRIAL METER
VZO / VZF
VZO is a volumetric meter with oscillating piston designed for fuel or mineral oil measurement. VZO may be fitted with a pulse emitter.
VZO / VZF
- Nominal size (qp)
- 400 ... 20,000 l/h
- Nominal diameter (DN)
- 15 ... 50 mm
- Temperature
- Up to 180 °C
- Interface
- Pulse
-
INDUSTRIAL METER
ARD
ARD is a volumetric meter with a rotary piston. A large choice of materials can be proposed for each measurement case. ARD may be fitted with a pulse emitter.
ARD
- Nominal size (qp)
- 200 ... 15,000 l/h
- Nominal diameter (DN)
- 15 ... 50 mm
- Temperature
- Up to +180 °C
- Interface
- Pulse
Thermische energiemeting
Onze ultrasone meters met communicatiemogelijkheid, die door ons zijn ontwikkeld en geproduceerd, hebben zich al vele jaren bewezen in systeemprojecten over de hele wereld, zelfs onder de zwaarste bedrijfsomstandigheden.
Er zijn 14 producten