ULTRASONIC COMPACT ENERGY METER
SHARKY 775
SHARKY with integrated OMS 868/434 MHz radio profile A or B as well other flexible plug&play modules. Extremely economical and durable with battery life of up to 16 years. Approved as heat and cooling meter in accordance with MID and PTB K 7.2.
SHARKY 775
- Nominal size (qp)
- 0.6 ... 100 m³/h
- Nominal diameter (DN)
- 15 ... 100 mm
- Approval
- MID class 2/3 PTB K 7.2 for cooling
- Temperature range
- 5 ... 130 (150) °C
- Interfaces
- Radio / M-Bus / LoRaWAN® / MOD / Pulse / RS232 ...
-
ULTRASONIC COMPACT ENERGY METER
SHARKY Solar 775
SHARKY Solar for Tyfocor LS glycol with integrated OMS 3.0 868/434 MHz radio and other flexible plug&play modules. Extremely economical and durable with battery life of up to 16 years.
SHARKY Solar 775
- Nominal size (qp)
- 0.6 … 2.5 m³/h
- Nominal diameter (DN)
- 15 … 20 mm
- Approval
- non
- Temperature range
- 5 … 130 °C
- Interfaces
- Radio / M-Bus / Pulse / RS232 / RS485 …
-
ULTRASONIC COMPACT ENERGY METER
SHARKY 774 compact
SHARKY with integrated OMS 3.0 868/434 MHz radio or M-Bus. Extremely economical and durable with battery life of up to 12 years. Approved as heat and cooling meter in accordance with MID and PTB K 7.2.
SHARKY 774 compact
- Nominal size (qp)
- 0.6 … 2.5 m³/h
- Nominal diameter (DN)
- 15 … 20 mm
- Approval
- MID class 2/3 PTB K 7.2 for cooling
- Temperature range
- 5 … 130 °C
- Interfaces
- Radio / M-Bus
-
ULTRASONIC COMPACT ENERGY METER
SHARKY 774
SHARKY with integrated OMS 868/434 MHz radio and M-Bus. Extremely economical and durable with battery life up to 12 years. Approved heating and cooling meter in accordance with MID and PTB K 7.2 for cooling. Dynamic range 1:100
SHARKY 774
- Nominal size (qp)
- 0.6 ... 10 m3/h
- Nominal diameter (DN)
- 15 ... 100 mm
- Approval
- MID class 2 / PTB K 7.2 for cooling
- Temperature range
- 5 ... 105 °C
- Interfaces
- Radio / M-Bus
-
ULTRASONIC FLOW SENSOR
SHARKY FS 473
SHARKY flow sensor with timed pulse values for any desired calculators. Extremely economical and durable with battery life of up to 12 years, or with external power supply. Approved as heat and cooling meter in accordance with MID and PTB K 7.2.
SHARKY FS 473
- Nominal size (qp)
- 0.6 … 100 m³/h
- Nominal diameter (DN)
- 15 … 100 mm
- Approval
- MID class 2/3 PTB K 7.2 for cooling
- Temperature range
- 5 ... 150 °C
- Interfaces
- Pulse
-
MECHANICAL FLOW SENSOR
RAY FS WP 457
Robust mechanical WP flow meter with mechanical counter for heat measurement. The counter provides a pulse output for connection to external calculators.
RAY FS WP 457
- Nominal size (qp)
- 15 ... 200 m³/h
- Nominal diameter (DN)
- 50 ... 200 mm
- Approval (MID)
- 10:1 qp / qi
- Temperature range
- 10 ... 120 °C
- Interfaces
- Pulse
-
MECHANICAL FLOW SENSOR
RAY FS WS 453/455
Robust mechanical WS flow meter with mechanical counter for heat measurement. The counter provides a pulse output for connection to external calculators.
RAY FS WS 453/455
- Nominal size (qp)
- 15 ... 150 m³/h
- Nominal diameter (DN)
- 50 ... 150 mm
- Approval (MID)
- 25:1 qp / qi
- Temperature range
- 15 ... 120 °C
- Interfaces
- Pulse
-
ENERGY CALCULATOR
SCYLAR INT 8
Calculator used in heat and cold metering to process flow-proportional pulses and determine temperature differences in a heating or cooling circuit with utmost precision.
SCYLAR INT 8
- Volume pulse input
- 0.01 … 10000 l/pulse
- Temperature sensor type
- Pt 100 or Pt 500 with 2- or 4-wire leads
- Approval
- MID and PTB K 7.2 (cooling)
- Temperature range
- -20 … 190 °C
- Interfaces
- Radio / M-Bus / Pulse
-
ENERGY CALCULATOR
SCYLAR INT 8 Glycol version
MID approved calculator used in heating and cooling applications. Scylar INT 8 glycol version with integrated OMS 3.0 radio and other flexible plug&play modules. Battery lifetime up to 16 years.
SCYLAR INT 8 Glycol version
- Volume pulse input
- 0.01 … 10,000 l/pulse
- Temperature sensor type
- Pt 100 or Pt 500 with 2- or 4-wire leads
- Temperature range
- 0 … +180 °C
- Interfaces
- Radio / M-Bus / Pulse / Modbus...
-
ENERGY CALCULATOR
SCYLAR INT M
2-channel energy calculator for measuring thermal energy. Wide temperature range from -50°C to 300°C. Even at ∆T=1K the verifications errors are considerably under-run. EMC protection for a high measuring accuracy and reliability.
SCYLAR INT M
- Two-channel calculator
- Two energy measurements per unit
- Temperature range (Absolute)
- -50 to 300 °C
- Volume pulse input
- up to 10kHz pulse/l
- Outputs
- 4 Active analog, 4 Pulse, 1 Relay, 1 M-Bus, 1 Optical, 1 USB, 4 Extra slots
- Inputs
- 4 Temp, 4 Pulse, 2 Analog
Thermische energiemeting
Onze ultrasone meters met communicatiemogelijkheid, die door ons zijn ontwikkeld en geproduceerd, hebben zich al vele jaren bewezen in systeemprojecten over de hele wereld, zelfs onder de zwaarste bedrijfsomstandigheden.
Er zijn 10 producten