WESAN WPV G
BULK WATER METER | WOLTMAN
Application
Meter for measuring heavily fluctuating flow rates.
Features
- Calibratable and exchangeable measuring insert in one unit, suitable for calibration comprising: measuring insert as main meter, switch-over valve, measuring capsule as bypass meter
- Ideal design of housing and housing cover prevents sedimentation, stagnant water and air pockets
- Bypass line integrated in housing cover. No risk of sedimentation or corrosion.
- No measuring errors in the switch-over range
- Measuring capsule as bypass meter and non-return valve easily replaced on site
- Encapsulated counter of glass/copper IP 68
- Good long-term measuring accuracy
- Complete head unit with counter and sensors can be rotated by 350° for easier reading
- System compatibility, WESAN WPV G can be extended with IZAR RADIO (clip on radio module) or IZAR PULSE (clip on pulse module)
- In order to secure a safe switch-over the WESAN WPV G needs a minimum ingoing pressure of 0.6 bar
-
General
Medium temperature range °C 1 ... 30 Temperature safety °C 1 ... 50 Ambient operating temperature °C 1 ... 55 Ambient storage temperature °C 1 ... 55 Nominal pressure PN bar 161 Display range 0.5 l ... 999,999 m³ Protection class IP 68 Available bypass meters ALTAIR MCI 1 versions with different nominal pressure on request (see also special versions) -
Technical data
Nominal diameter DN mm 50 80 100 Permanent flow rate Q3 m³/h 25 63 100 Minimum flow rate Q1 l/h 252 252 252 Transitional flow rate Q2 l/h 402 402 402 Overload flow rate Q4 m³/h 31.25 78.75 125 Starting flow rate l/h 22 22 22 Permanent flow rate bypass meter Q3 m³/h 4 4 4 Switch-over flow rate rising m³/h 2.2 2.7 2.4 Switch-over flow rate falling m³/h 0.9 1.1 1.2 2 with bypass meter ALTAIR MCI -
Approval
Nominal diameter DN mm 50 80 100 MID (DE-16-MI001-PTB002) • • • Dynamic range bypass meter ALTAIR MCI (Q3/Q1) R 1000 2500 4000 Potable water KTW / W270 KTW / W270 KTW / W270 -
REACH
Information pursuant to Article 33 (1) of Regulation (EC) No 1907/2006 of the European Parliament and of the Council of 18 December 2006:
This product series contains articles with the following substances in a concentration of more than 0.1% weight by weight (w/w):
- Lead (CAS no.: 7439-92-1) -
Special versions
- Versions with different nominal pressure on request
- Special flange holes on request -
Dimensions
Nominal diameter DN mm 50 80 100 Overall length (DIN 19625) L mm 270 300 360 Overall length (DIN ISO 4064) L mm - 300 350 Flange diameter D mm 165 200 220 Hole circle diameter K mm 125 160 180 Number of screwholes pcs 4 8 / 4 8 Screwhole diameter D1 mm 18 18 18 Height H mm 76 105 101 Height H1 mm 115 135 140 Height H2 mm 1742 1752 1462 Height to remove measuring insert mm 2502 2802 2802 Width B1 mm 85 100 110 Width B2 mm 160 180 180 Diameter Ø B mm 110 110 110 Weight of complete meter kg 17.4 25.5 29 Weight of measuring insert kg 6.3 9.3 9.3 2 with bypass meter ALTAIR MCI -
Pressure loss graph / Typical error graph