WESAN WPV A (phased out)

Bulk Water Meter | Woltman

Application

Meter for measuring heavily fluctuating flow rates.

Features

  • Ideal design of housing and housing cover prevents sedimentation, stagnant water and air pockets
  • No measuring errors in the switch-over range
  • Good long-term measuring accuracy
  • Complete head unit with counter and sensors can be rotated by 350° for easier reading
  • Main meter and bypass meter are prepared for connection of two reed switch and one opto transmitter
  • In order to secure a safe switch-over the WESAN WPV A needs a minimum ingoing pressure of 0.6 bar
  • General
    Medium temperature range°C1 ... 30
    Temperature safety°C1 ... 50
    Ambient operating temperature°C1 ... 55
    Ambient storage temperature°C1 ... 55
    Nominal pressurePNbar161
    Display range0.05 l ... 99,999 m³
    Protection classIP 65
    Available bypass meterCORONA DP
    1 versions with different nominal pressure on request (see also special versions)
  • Technical data
    Nominal diameterDNmm150
    Permanent flow rateQ3m³/h160
    Minimum flow rateQ1l/h400
    Transitional flow rateQ2l/h640
    Overload flow rateQ4m³/h200
    Starting flow ratel/h60 - 70
    Permanent flow rate bypass meterQ3m³/h16
    Switch-over flow rate risingl/h4450
    Switch-over flow rate fallingl/h7750
  • Approval
    Nominal diameterDNmm150
    MID (DE-17-MI001-PTB003)
    Dynamic range bypass meter CORONA DP (Q3/Q1)R400 H
    Potable waterKTW / W270
  • Dimensions
    Nominal diameterDNmm150
    Overall length (DIN 19625)Lmm500 ± 15
    Flange diameterDmm285
    Hole circle diameterKmm240
    Number of screwholespcs8
    Screwhole diameterD1mm22
    HeightHmm150
    HeightH1mm230
    Height to remove measuring insertmm475
    WidthB1mm143
    WidthB2mm290
    DiameterØ Bmm115
    Weight of complete meterkg68
  • Special versions

    - Versions with different nominal pressure on request
    - Special flange holes on request

  • Pressure loss graph / Typical error graph