CORONA E
CORONA E
Fully electronic compact water meter with impeller scanning for recording volume. Highly accurate recording of all billing data at medium temperatures up to 90 °C.
- Electronic sensor control for recording flow rate
- Lithium battery, lifetime up to 12 years
- Optical ZVEI interface equipped as standard
- Adjustable reading date for billing
- Rotatable integrator
- Single-line 7-digit display for easy meter reading
-
Electronic - Basic features
Ambient class OIML R49 class C / MID E2 + M1 Protection class IP 54 or IP 68 for cold and warm water meter Interfaces standard Optical ZVEI Interfaces optional1 M-Bus, L-Bus, pulse 1 Possible combinations
- M-Bus / pulse / pulse
- L-Bus / forward pulse
- only M-Bus
Note: IZAR@SET / HYDRO-SET Software for configuration of meters, readout of measured values and printout of meter logs. Available under www.diehl.com/metering (Products - downloads) -
Technical data display
Display indication LCD, 7-digit Unit m³/h - l/h - m³ - l Total values 99,999.99 Values displayed Flow rate -
Supply voltage
Operating voltage UN VDC 3.0 (lithium battery) Battery lifetime Up to 12 years Nominal power PN μW 30 -
Interfaces - Overview
Optical ZVEI interface for communication, M-Bus protocol M-Bus According to EN 1434-3. Data reading and parametrization are via two wires with polarity reversal protection. (Meter is powered with energy via M-Bus Master) L-Bus Interface for the radio module IZAR RADIO EXTERN Pulse Output for volume -
Pulse interface - Specification
Pulse rates l/pulse Decadic 0.1 ... 100 Display 2 digits after comma Pulse value 1 l/pulse 0.1 (factory setting) Pulse value 2 l/pulse 1 (factory setting) Pulse variants Two forward pulses; one forward and one backward pulse; pulse and direction signal Note: In the field the pulse values can be configured as desired in the specified value range. -
Volume- / Pulse
Output type Open collector Max. frequency Hz 90 Max. input voltage V 30 Max. input current mA 27 Max. voltage drop at active output V/mA 2/27 Max. current through inactive output μA/V 5/30 Max. reverse voltage without destroying outputs V 6 Min. pulse duration ms 5.5 (at max. frequency of 90 Hz) Max. pulse duration s 2 Min. pulse pause ms 5.5
-
General
Temperature range °C 30 (for cold water meter) / 90 (for warm water meter) Ambient operating temperature °C 1 ... 55 Ambient storage temperature °C -20 ... 55 Nominal pressure PN bar 10 / 16 Mounting position In any position -
Technical data
Nominal diameter DN mm 15 15 15 20 20 20 Permanent flow rate Q3 m³/h 2.5 2.5 2.5 4 4 4 Overall length L mm 110 130 165 105 130 190 Overload flow rate Q4 m³/h 3.125 3.125 3.125 5 5 5 Transitional flow rate Q2 l/h 32 32 32 51 51 51 Minimum flow rate Q1 l/h 201 201 201 321 321 321 Starting flow rate l/h 3 - 4 3 - 4 3 - 4 5 - 6 5 - 6 5 - 6 Pressure loss at Q3 Δp mbar 615 615 615 620 620 620 Flow rate at 0.1 bar pressure loss m³/h 0.962 0.962 0.962 1.607 1.607 1.607 Flow rate at 1 bar pressure loss (30 °C) m³/h 1 at R 125 -
Approval
Nominal diameter DN mm 15 15 15 20 20 20 Permanent flow rate Q3 m³/h 2.5 2.5 2.5 4 4 4 Overall length L mm 110 130 165 105 130 190 MID (DE-07-MI001-PTB008) - T30 • • • MID (LNE 12552) - T90 • • • MID (LNE 13629) - T30/T90 • • • MID (LNE 14587) - T30/T90 Dynamic range (Q3/Q1) R 80 / 100 / 125 80 / 100 / 125 80 / 100 / 125 80 / 100 / 125 80 / 100 / 125 80 / 100 / 125 -
Dimensions
Nominal diameter DN mm 15 15 15 20 20 20 Permanent flow rate Q3 m³/h 2.5 2.5 2.5 4 4 4 Overall length L mm 110 130 165 105 130 190 Overall length with coupling L2 mm 186 206 241 181 206 266 Connection thread on meter Inch G¾B G¾B G¾B G1B G1B G1B Connection thread of coupling Inch R½ R½ R½ R¾ R¾ R¾ Flange diameter D mm Hole circle diameter K mm Number of screwholes pcs Screwhole diameter D1 mm Height H mm 20 20 20 20 20 20 Height H1 mm 75 75 75 75 75 75 Diameter Ø B mm 62 62 62 62 62 62 Width A mm Weight without coupling kg 0.8 1 1.3 0.8 1 1.5 Weight with coupling kg 1 1.2 1.5 1.3 1.5 2 Weight with flanges kg - Pressure loss graph / typical error graph