HYDRUS 2.0

ULTRASONIC METER

Application

HYDRUS 2.0 is a static ultrasonic water meter designed for all applications of domestic cold water supply enabling accurate measuring with long-term stability under difficult conditions (no measurement of air and insensitive to sedimentation). Developed within the framework of the MID, it complies with the European regulations and holds sanitary conformity certificates (AoC DEU, ACS, WRAS and others). The integrated communication function supports meter data provision via mobile reading (walk-by/drive-by/passive drive-by) or fixed network (upgrade without on-site configuration). In combination with Diehl Metering’s IZAR fixed network system, which stands out with excellent coverage, high data granularity and timeliness will be maintained. This is what makes it a high responsive infrastructure to take actions immediately.

Features

  • DN 15 to 50 threads
  • MID approved with dynamic range up to R 800
  • IP 68 suitable for outdoor installations
  • Integrated communication based on OMS specifications
  • Wireless M-Bus for mobile reading in parallel to Fixed Network
  • mioty®4OMS for OMS Generation 5 Fixed Network
  • OMS over LoRaWAN® for LoRaWAN Fixed Network
  • M-Bus/Pulse/Pulse, wireless M-Bus, wireless M-Bus along with L-Bus/Pulse
  • Display with error and alarm codes including leakage detection
  • Battery lifetime up to 16 years
  • U0 / D0, no need for calming sections
  • Privacy

    The HYDRUS 2.0 stores internally historical consumption values. The logging data is only available by local reading with IZAR@MOBILE. Optical and radio communication implements encryption and authentification according to OMS Specification and LoRaWAN® specification.

  • Reach

    Information pursuant to Article 33 (1) of Regulation (EC) No 1907/2006 of the European Parliament and of the Council of 18 December 2006:
    This product series contains components with the following substances in a concentration of more than 0.1% weight by weight
    (w/w):
    - Lead (only for the flange variants) - (CAS no.: 7439-92-1)
    - Lead titanium zirconium oxide (CAS no.: 12626-81-2)

  • General
    Medium temperature range°C+0.1 ... +90
    Ambient operating temperature°C-10 ... +55
    Ambient storage temperature°C-10 ... +70 (>35 °C max. 4 weeks)
    Environmental classO (Outdoors)
    Mechanical environmental classM2
    Electromagnetic environmental classE2
    Housing materialWith thread connection: CW724R (lead-free); with flange connection: CC770S
    Nominal pressurePNbar16
    Power supplyTwo 3.6 VDC lithium batteries
    Battery lifetime T301/T501Up to 16 years
    Battery lifetime T701/T901Up to 16 years
    Communication interfacesOptical, OMS Generation 5 (mioty®4OMS) 868 MHz, OMS Generation 3/4 wireless M-Bus 434/868 MHz, M-Bus, L-Bus and Pulse, LoRaWAN® 868 MHz, mioty® for Metering 434/868 MHz
    Data storageFor errors, alarms and measuring values, data logging capabilities to record up to 1024 daily values +32 monthly values and two annual due dates
    Protection classIP 68
    1 Depends on the sending interval of the radio telegram, the telegram length and the ambient temperature at the installation
  • Technical Data Display
    Display indicationLCD, 9-digit, additional symbols/display counter/unit
    Units displayed DN 15 - DN 50Volume (m³ + 3 decimal places) and flow rate (m³/h + 3 decimal places)
    Unit displayed DN50 (only for DMFR)Volume (m³ + 2 digits after decimal point) and flow rate (m³/h + 3 digits after decimal point)
    Values displayedDisplay test - volume - battery lifetime - firmware version - software checksum - flow - current/continuous/historical error - alarm status - high resolution volume - due date - due date volume - reverse volume - display counter - low battery indication - leakage indication - metrological log access - radio signal ON/OFF - alarm indication - billing value indication - and more display loop options to choose from.
  • Interfaces - Overview
    OpticalFor switching the display loop and configuring / reading the meter via IZAR@MOBILE
    Wireless M-Bus434 or 868 MHz, OMS Generation 3/4, OMS radio as standard for mobile reading (R3) sent every 14 / 64 seconds (default) and wireless M-Bus for fixed network (R4/R4+) sent every 5 / 15 / 60 minutes
    mioty®4OMS868 MHz, OMS Generation 5, OMS as standard for mobile reading (R3) sent every 64 seconds (default) and mioty®4OMS for fixed network sent every 60 minutes
    mioty® for Metering 434 or 868 MHz, OMS Generation 3/4, OMS radio as standard for mobile reading (R3) sent every 64 seconds (default) and mioty® for Metering for fixed network (L1C) sent every 60 minutes
    LoRaWAN®868 MHz - OMS over LoRaWAN® for fixed network sent every 3 h / 5 h / 6 h (default) and OMS for mobile reading (R3) sent every 64s (default); Complies to v1.0.3, certified to v1.0.2, Class A, supports Adaptive data rate (ADR) and Over The Air (OTA) activation
    M-Bus2400 baud, cable length 1.5 m, power supply only via built-in battery - can be combined with two Pulse outputs
    L-BusIn combination with radio, cable length 1.5 m (only one interface communicating at the same time)
    Pulse (Open drain)Two Pulse outputs, or one Pulse and one L-Bus output, Pulse cable length 1.5 m
  • Security
    Wireless M-BusOMS Generation 4 Profile B, individual keys (default) / OMS Generation 3 (selectable)
    mioty®4OMSOMS Generation 4 Profile B, individual keys (default)
    mioty® for MeteringOMS Generation 4 Profile B, individual keys (default) / OMS Generation 3 (selectable)
    LoRaWAN®Fixed Network uses internal LoRaWAN® transport encryption; Mobile Network uses OMS Generation 4 Profile B Individual keys
  • Volume / Pulse Open Drain
    Max. input voltageV30
    Max. input currentmA27
    Max. voltage drop at active outputV/mA2/27
    Max. current through inactive outputμA/V5/30
    Max. reverse voltage without destroying outputsV6 (in case current does not exceed 27 mA)
    Pulse ratesl/pulseDecadic 1 / 10 (depending on nominal diameter)
    Pulse output 1 variantsTotal volume or forward volume
    Pulse output 2 variantsFlow direction or error, reverse volume
    Pulse frequencyMax. frequency 10 Hz
    Pulse width50 - 125 ms
  • Possible Communication Interfaces
    Wireless M-Bus/Pulse/L-Bus3 wire
    Wireless M-Bus onlywithout wire
    mioty®4OMS and OMS Radiowithout wire
    LoRaWAN® and OMS radiowithout wire
    M-Bus only2 wire
    M-Bus/Pulse/Pulse5 wire
    Pulse/Pulse3 wire
    IZAR BE PULSE4 wire
    Line for DMFR onlyWith IZAR BE PULSE completly soldered to HYDRUS 2 to put a radio clip-on module (LoRaWAN, Wize, OMS)
  • Technical Data
    Nominal diameterDNmm1515315152020202020
    Permanent flow rateQ3m3/h2.52.52.52.52.52.5444
    Overall lengthLmm110115165170130190130165190
    Dynamic (Q3/Q1)R800800800800800800800800800
    Overload flow rateQ4m3/h3.1253.1253.1253.1253.1253.125555
    Transitional flow rateQ2l/h555555888
    Minimum flow rateQ1l/h3.133.133.133.133.133.13555
    Starting flow ratel/h1.41.41.41.41.41.42.52.52.5
    Pressure loss at Q3bar0.460.460.460.460.40.40.40.40.4
    Pressure loss at Q4bar0.720.720.720.720.630.630.630.630.63
    Maximum flow rate2Qhighm³/h4.374.374.374.374.374.37777
    Flow rate at ΔP = 1 bar3.693.693.693.693.953.955.395.395.39
    2 Outlet pressure minimum 3 bar, maximum 100 hours per year, closed pipeline network
    3 Please see table DIMENSIONS
  • Approval
    ApprovalMID DE-19-MI001-PTB012
    Dynamic range (Q3/Q1)RUp to 800
    StandardsEN 4064, EN 14154, OIML R49
    Sanitary conformityAoC DEU, ACS, WRAS, Belgaqua, KIWA Netherlands, OTH, PZH, SVGW
    OMS CertificationOMS Generation 4
    LoRaWAN® certification1.0.2
  • Dynamic Range (R=Q3/Q1)
    Q3 1.6 m³/h - T30 / T50R400
    Q3 1.6 m³/h - T70 / T90R400H; 250V
    Q3 2.5 m³/h - T30 / T50R160; 800 (400 for L 115 mm)
    Q3 2.5 m³/h - T70 / T90R160; 400; 800H / 400 V (250 for L 115 mm)
    Q3 4 m³/h - T30R160; 400; 800 (630 for L 105 mm and 115 mm)
    Q3 4 m³/h - T50 / T70 / T90R160; 400; 800H / 400V (630H for L 105 mm and 115 mm)
    H=horizontal installation position / V=vertical installation position
    Other values on request
  • Dimensions
    Nominal diameterDNmm1515315152020202020
    Permanent flow rateQ3m3/h2.52.52.52.52.52.5444
    Overall lengthLmm110115165170130190130165190
    Housingbrass/compositebrass/compositebrass/compositebrass/compositebrassbrass/compositebrassbrassbrass/composite
    Counter lengthL1mm898989898989898989
    Counter widthBmm898989898989898989
    Body (DMFR only) brass/compositebrass/compositebrass/compositebrass/compositebrassbrass/compositebrassbrassbrass/composite
    Overall length with couplingL2mm190195245250230290230295290
    Connection thread on meterInchG¾BG¾BG¾BG¾BG1BG1BG1BG1¼BG1B
    Connection thread of couplingInchR1
    HeightH1mm717171717474747474
    Weight without coupling (approx.)kg0.7 / 0.50.7 / 0.50.8 / 0.60.8 / 0.60.80.9 / 0.60.81.00.9 / 0.6
    Weight with coupling (approx.)kg1.1 / 0.91.1 / 0.91.2 / 1.01.2 / 1.01.21.3 / 1.01.21.61.3 /1.0
    HeightHmm181818182121212721
    3 Further version with connection thread on meter inlet G7/8B and meter outlet G3/4B on request.
    4 Wrench size should not be bigger than 38 mm
  • Pressure loss graph / Typical error graph

  • Technical Data
    Nominal diameterDNmm2525324040404050505050
    Permanent flow rateQ3m3/h6.310101010161616162525
    Overall lengthLmm260260260200300200300270300270300
    Dynamic (Q3/Q1)R400800800400400800800250250400400
    Overload flow rateQ4m3/h7.8712.512.512.512.52020202031.2531.25
    Transitional flow rateQ2l/h25.2202040403232102102100100
    Minimum flow rateQ1l/h15.812.512.525252020646462.562.5
    Starting flow ratel/h5558.78.78.78.725252525
    Pressure loss at Q3bar0.220.540.330.220.220.20.20.140.140.330.33
    Pressure loss at Q4bar0.340.840.530.340.340.310.310.220.220.520.52
    Maximum flow rate2Qhighm³/h11.0217.517.517.517.5282832.1332.1332.1332.13
    Flow rate at ΔP = 1 bar13.4313.4310.9521.3221.3236.036.044.044.044.044.0
    2 Outlet pressure minimum 3 bar, maximum 100 hours per year, closed pipeline network
  • Approval
    ApprovalMID DE-19-MI001-PTB012
    Dynamic range (Q3/Q1)RUp to 800
    StandardsEN 4064, EN 14154, OIML R49
    Sanitary conformityAoC DEU, ACS, WRAS, Belgaqua, KIWA Netherlands, OTH, PZH, SVGW
    OMS CertificationOMS Generation 4
    LoRaWAN® certification1.0.2
  • Dynamic Range (R=Q3/Q1)
    Q3 6.3 m³/h - T30R160; 400
    Q3 6.3 m³/h - T50 / T70 / T90R160; 400H / 250V
    Q3 10 m³/h - DN 25, DN 32 - T30R160; 400; 800
    Q3 10 m³/h - DN 25, DN 32 - T50 / T70 / T90R160; 400; 800H / 400V
    Q3 16 m³/h - DN 40 - T30R160; 400; 800
    Q3 16 m³/h - DN 40 - T50 / T70 / T90R160; 400; 800H / 400 V
    Q3 16 m³/h - DN 50R250
    Q3 25 m³/h - DN 50R400
    H=horizontal installation position / V=vertical installation position
    Other values on request
  • Dimensions
    Nominal diameterDNmm2525324040404050505050
    Permanent flow rateQ3m3/h6.310101010161616162525
    Overall lengthLmm260260260200300200300270300270300
    Counter lengthL1mm8989899696969692929292
    Counter widthBmm8989898989898994949494
    Body (DMFR only)brassbrassbrassbrassbrassbrassbrassbrassbrassbrassbrass
    DIMENSIONS - THREAD...........
    Overall length with couplingL2mm380380380340440340440390420390420
    Connection thread on meterInchG1¼BG1¼BG1½BG2BG2BG2BG2BG2½BG2½BG2½BG2½B
    Connection thread of couplingInchR1R1R1¼R1½R1½R1½R1½R2R2R2R2
    HeightH1mm7878788282828290909090
    Weight without coupling (approx.)kg1.41.41.51.82.61.82.63.94.053.94.05
    Weight with coupling (approx.)kg2.02.02.13.03.83.03.85.55.655.55.65
    HeightHmm2727303636363641414141
    DIMENSIONS - FLANGE...........
    Flange diameterDmm115115140-148-148----
    Hole circle diameterKmm8585100-110-110----
    Number of screwholespcs444-4-4----
    Screwhole diameterD1mm141418-18-18----
    HeightHmm505062.5-69-69----
    HeightH1mm848484-87-87----
    WidthFmm100100125-138-138----
    Weight with flanges (approx.)kg3.43.44.6-6.3-6.3----
  • Pressure loss graph / Typical error graph