ALTAIR V4 IS HOT WATER

VOLUMETRIC METER

Application

ALTAIR V4 IS HOT WATER is the latest generation of volumetric meter designed to measure the consumption of domestic hot water.
Compact and robust, ALTAIR V4 IS HOT WATER is easy to install and perfectly suited for varying water qualities.
Its integrated radio enables remote reading of the index and alarms of the meter in mobile mode (walk-by) or fixed network.
Developed within the framework of the MID, it complies with the European regulations and holds sanitary conformity certificates.

Features

  • DN15
  • Q3=1.6m3/h / Q3=2.5m3/h
  • MID approval up to R=400
  • Starting flow rate: 1 l/h
  • Water temperature from 30°C to 90°C
  • Brass body
  • IZAR integrated 868 MHz radio, PRIOS protocol
  • Battery lifetime up to 10 years
  • IP54 - not suitable for wet environment
  • Metrological data
    Nominal diameterDNmm1515
    LengthLmm110110
    Nominal flow rateQ3m³/h1.62.5
    R standard*Q3/Q1100160
    Starting flow ratel/h11
    Minimum flow rateQ1l/h1615.62
    Transition flow rateQ2l/h25.625
    Maximum flow rateQ4m³/h23.125
    Head loss at Q3bar0.220.54
    Head loss at Q4bar0.340.85
    Kvs (deltaP=Q²/Kvs²)3.383.38
    * Other values on request
  • Approval
    MID approvalLNE-6250 | Type A2
    Standards EN 14154 | ISO 4064 | OIML R49
    Sanitary conformityACS | WRAS
  • REACH

    Information pursuant to Article 33 (1) of Regulation (EC) No 1907/2006 of the European Parliament and of the Council of 18 December 2006:
    This product series contains components with the following substances in a concentration of more than 0.1% weight by weight (w/w):
    - Lead (CAS no.: 7439-92-1)

  • Temperatures and pressure
    Water temperature°C+30 ... +90
    Operating ambient temperature°C+5 ... +50
    Storage temperature°C-20 ... +55
    Nominal pressurePNbar16
    Degree of protectionIP 54
  • Technical data IZAR integrated radio
    Communication protocolPRIOS
    FrequencyMHz868.95 (R3 mode)
    Sending intervalEvery 32 seconds
    StandardsEN 300 220 | RED directive | EN 13757-3/-4
    Transmission powermW16
    Transmission modeUnidirectional
    Radio rangeUp to 500 m depending on the environment
    Power supply3 V lithium battery
    Typical battery lifetimeUp to 10 years*
    Integrated functionsCurrent index | Historical index value | Remaining battery lifetime
    Alarms managementLeak detection | Meter stopped | Overflow | Underflow | Backflow
    * Under standard conditions of use and temperature. Theoretical lifetime, not guaranteed.
  • Dimension
    Nominal diameterDNmm1515
    LengthLmm110110
    Nominal flow rateQ3m³/h1.62.5
    WidthBmm96.296.2
    HeightHmm123123
    HeightH1mm2727
    HeightH2mm9696
    Thread connectionsGinch3/4"3/4"
    Bodybrassbrass
    Weightkg0.890.89
  • Precision curve

    This technology does not require straight length.

  • Options

    - Pair of connectors
    - Stainless steel pocket filter