CORONA MCI 108

MULTI-JET METER | WET RUNNER

Application

Domestic water meter

Features

  • Modular multi-jet domestic capsule meter with inductive scanning (without magnetic influence)
  • System capability, with standard applicable pulse output 1 l/pulse (inductive). CORONA MCI can be externed in any way - with IZAR RADIO COMPACT 868 I (radio module) or IZAR PULSE I (pulse transmitter)
  • Only the complete measuring insert needs to be replaced regularly at the end of the calibration period - the meter housing remains fitted in the pipeline
  • With composite screw head. Advantage: lower adhesion, no deposit, lower weight
  • For easier reading, the zero point of the dial can be adapted to the direction of flow by turning the measuring capsule 90° to either side during installation
  • A DIN DVGW-approved non-return valve can be installed in the meter housing as option
  • Mounting position - housing horizontal: horizontal (R 40 - 160) and vertical (R 40)
  • Mounting position - housing rising pipe: vertical (R 40 - 160)
  • General
    Medium temperature range°C1 ... 30
    Temperature safety°C1 ... 50
    Ambient operating temperature°C1 ... 55
    Ambient storage temperature°C1 ... 55
    Nominal pressurePNbar16
    Display range0.05 l ... 99,999 m³
    Pulse valuel/pulse1
    Protection classIP 68
  • Technical data
    Nominal diameterDNmm1520
    Permanent flow rateQ3m³/h2.54
    Overload flow rateQ4m³/h3.1255
    Transitional flow rateQ2l/h4040
    Minimum flow rateQ1l/h252253
    Starting flow ratel/h46
    Dynamic range horizontal installation (Q3/Q1)R40 / 80 / 10040 / 80 / 100 / 160
    Dynamic range vertical installation (Q3/Q1)R-40
    Dynamic range (Q2/Q1)1.61.6
    Pressure loss at Q3bar0.450.6
    Flow rate at 1 bar pressure loss1m³/h3.36.5
    1 without non-return valve
    2 based on R 100
    3 based on R 160
  • Approval
    MID approvalMID TH 8629
  • Reach

    Information pursuant to Article 33 (1) of Regulation (EC) No 1907/2006 of the European Parliament and of the Council of 18 December 2006:
    This product series contains articles with the following substances in a concentration of more than 0.1% weight by weight (w/w):
    - Lead

  • Dimensions
    Nominal diameterDNmm1520
    Permanent flow rateQ3m³/h2.54
    Overall length (DIN ISO 4064)Lmm165 / 170190
    Overall length with couplingL2mm245288
    Connection thread on meter (ISO 228/1)InchG¾BG1B
    Connection thread of coupling (DIN 2999)Inch
    HeightHmm2222
    HeightH1mm117117
    Height to remove measuring insertmm200200
    DiameterØ Bmm9595
    WidthAmm-
    Weight without couplingkg1.151.2
    Weight with couplingkg1.41.6
  • Pressure loss graph / Typical error graph

  • General
    Medium temperature range°C1 ... 30
    Temperature safety°C1 ... 50
    Ambient operating temperature°C1 ... 55
    Ambient storage temperature°C1 ... 55
    Nominal pressurePNbar16
    Display range0.05 l ... 99.999 m³
    Pulse valuel/pulse1
    Protection classIP 68
  • Technical data
    Nominal diameterDNmm20
    Permanent flow rateQ3m³/h4
    Overload flow rateQ4m³/h5
    Transitional flow rateQ2l/h40
    Minimum flow rateQ1l/h252
    Starting flow ratel/h6
    Dynamic range (Q3/Q1)R40 / 80 / 100 / 160
    Dynamic range (Q2/Q1)1.6
    Pressure loss at Q3bar0.6
    Flow rate at 1 bar pressure loss1m³/h5.8
    1 without non-return valve
    2 based on R 160
  • Approval
    MID approvalMID TH 8629
  • Reach

    Information pursuant to Article 33 (1) of Regulation (EC) No 1907/2006 of the European Parliament and of the Council of 18 December 2006:
    This product series contains articles with the following substances in a concentration of more than 0.1% weight by weight (w/w):
    - Lead

  • Dimensions
    Nominal diameterDNmm20
    Permanent flow rateQ3m³/h4
    Overall length (DIN ISO 4064)Lmm105
    Overall length with couplingL2mm203
    Connection thread on meter (ISO 228/1)InchG1B
    Connection thread of coupling (DIN 2999)Inch
    HeightHmm27
    HeightH1mm145
    Height to remove measuring insertmm200
    DiameterØ Bmm95
    WidthAmm95
    Weight without couplingkg1.6
    Weight with couplingkg2
  • Pressure loss graph / Typical error graph