ALTAIR MCI COMPOSITE 119

ROTARY PISTON METER

Application

Domestic rotary piston water meter (only complete meter)

Features

  • Low noise level
  • System compatibility, with standard applicable pulse output 1 l/pulse. ALTAIR MCI can be extended - with IZAR RADIO (radio module) or IZAR PULSE (pulse transmitter)
  • Any mounting position + no calming sections necessary
  • Low starting flow approximately 0.7 l/h permits recording of very small amounts of water
  • Self-cleaning mechanism of measuring chamber
  • Encapsulated roller counter unit rotatable by 350°
  • Nearly 50 % lighter than meter with brass body
  • Suitable for fully demineralized water
  • General
    Medium temperature range°C1 ... 30
    Temperature safety°C1 ... 50
    Ambient operating temperature°C1 ... 50
    Ambient storage temperature°C1 ... 50
    Nominal pressurePNbar16
    Display range8-digit, 0.001 l ... 99,999 m³
    Pulse valuel/pulse1
    Protection classIP 68
  • Technical data
    HousingHorizontal
    Nominal diameterDNmm20
    Permanent flow rateQ3m³/h4
    Overload flow rateQ4m³/h5
    Transitional flow rateQ2l/h80
    Minimum flow rateQ1l/h251
    Starting flow ratel/h0.7
    Pressure loss at Q3bar0.6
    1 Based on R 160
  • Approval
    MIDLNE-6250
    Dynamic range (Q3/Q1)R40 / 80 / 160
    Potable waterAoC DEU
  • Dimensions
    HousingHorizontal
    LengthLmm160
    Overall length (DIN ISO 4064)L1mm190
    Connection thread on meterInchG1B
    HeightHmm97
    HeightH1mm27
    HeightH2mm144
    DiameterØ Bmm93
    Weight of capsulekg0.57
    Weight of complete meterkg0.82
  • Pressure loss (delta P = Q²/Kvs²)
    Kvs5.25