IZAR PORT PULSE MINI

M-BUS KONVERTER

Application

The IZAR PORT PULSE MINI offers the possibility to connect resource meters with pulse output to an M-Bus network (transformation of pulses to M-Bus protocol). It is suitable for all meter types with pulse transmitter or open collector output.

Features

  • Two independent pulse counters
  • Configuration via M-Bus interface using HYDRO-PORT software
  • Physical unit and medium programmable for each input
  • Pulse divisor programmable for each input
  • Power supply via M-Bus, battery supply to continue pulse counting if M-Bus fails
  • Splash water protected (IP 54)
  • Wall mounting possibility
  • Principle of operation

    The IZAR-PORT PULSE MINI consists of an electronic unit that collects meter information in the form of pulses. These pulse counts are converted into physical units. The data is transmitted via M-Bus protocol to a data concentrator (M-Bus Master IZAR CENTER).

  • General
    HousingLight-grey plastic housing with wall mounting support
    Cable lengthMax. 1.5 m for connecting pulse transmitter / open collector
    InterfacesM-Bus output; 2 independent (voltage-free) pulse inputs
    ConfigurationVia M-Bus and HYDRO-PORT software (free of charge)
  • Technical data
    Power supplyVia M-Bus or Lithium battery 3.6 V
    Pulse frequencyHz50
    Pulse widthms7.5
    Weightg150
    Protection classIP 54
  • Ambient conditions
    Humidity%10 ... 80
    Temperature range°C0 ... 60
  • Dimensions
    LengthLmm88
    WidthBmm88
    HeightHmm49