HYDRUS 2.0 BULK
ULTRASONIC METER
Application
HYDRUS 2.0 BULK is a static water meter operating on ultrasonic measuring technology. This technology enables accurate calculation of water consumption with long-term stability and eliminates measuring deviations caused by sand, suspended particles, scale or air pockets. Moreover it does not require any earthing.
Developed within the framework of the MID, HYDRUS 2.0 BULK complies with the European regulations and holds sanitary conformity certificates (ACS, WRAS, BELGAQUA, DM174 and others). The meter is also designed for cold and hot water.
Its integrated radio enables remote reading of the meter's index and alarms both in mobile (walk-by, drive-by, passive drive-by) and fixed network mode.
HYDRUS 2.0 BULK offers a wide choice of connectivities compatible with the different IZAR reading modes.
A complete Diehl Metering solution is thus available to meet your needs.
Features
- DN 50 to 200
- MID approval up to R=1,000
- IP 68
- Wireless M-Bus radio, Wired M-Bus/Pulse/Pulse, Wireless M-Bus radio/L-Bus/Pulse, Pulse (IZAR BE PULSE compatible)
- Display with symbols and error codes
- Self-monitoring function
- Battery lifetime up to 16 years
-
Privacy
The HYDRUS 2.0 BULK saves 512 daily consumption values. This data can be read locally and accessed only by using the IZAR@MOBILE 2. As a second logging, a small amount of 32 monthly consumption values can be stored. Both the radio protocol and the optical interface are encrypted by default.
-
Technical data
Water temperature °C +0.1 ... +50 (T30 / T50) | +0.1 ... +90 (T90) Accuracy Class 2 according to ISO 4064:2014 / OIML R49:2013 Ambient operating temperature °C -10 ... +55 Ambient storage temperature °C -10 ... +70 (>35 °C max. 4 weeks) Environmental class O (Outdoors) Mechanical environmental class M2 Electromagnetic environmental class E2 Flow profile sensitivity class U0/D0 (no calming sections required) Installation position Horizontal, inclined 45°, inclined 90°, vertical Nominal pressure PN bar 16 Pressure loss class Δp bar 0.16 Power supply 3.6 V lithium battery (D-cell) Battery lifetime1 Up to 16 years (all communication interfaces) Communication interfaces Optical, OMS wireless M-Bus 434 or 868 MHz, M-Bus, L-Bus and Pulse Data storage For errors, alarms and measuring values, data logging capabilities to record up to 512 daily + 32 monthly values Protection class IP 68 1 Theoretical lifetime, depends on the sending interval of the radio telegram, the telegram length and the ambient temperature at the installation. -
Technical data display
Display indication LCD, 9-digit, additional symbols/display counter/unit Units displayed DN 50 - 100 Volume (m³ + 2 digits after decimal point) and flow rate (m³/h + 3 digits after decimal point) Units displayed DN 125 - 200 Volume (m³ + 1 digit after decimal point) and flow rate (m³/h + 3 digits after decimal point) Values displayed Display test - volume - battery lifetime - firmware version - software checksum - flow - current/continuous/historical error - alarm status - high resolution volume - due date - due date volume - reverse volume - flow direction - display counter - low battery indication - leakage indication - metrological log access - radio signal ON/OFF - alarm indication - billing value -
Communication interfaces
Optical For switching the display loop, reading and configuration with IZAR@MOBILE 2 Radio 434 or 868 MHz, Open Metering Standard (OMS) radio frame (short frame) for mobile reading sent every 14 seconds, long range radio frame for fixed network sent every 5 minutes, extra long range radio frame for fixed network sent every 15 minutes M-Bus 2,400 baud, cable length 1.5 m*, power supply only via built-in battery - is combined with 2 pulse outputs L-Bus In combination with radio, cable length 1.5 m* (only 1 interface communicating at the same time) Pulse (Open drain) 2 pulse outputs, or 1 pulse and 1 L-Bus output, pulse cable length 1.5 m* *May vary by up to ±3.5% due to manufacturing tolerances. -
Security
Versions OMS Generation 3 - Profile A or OMS Generation 4 - Profile B -
Volume / Pulse open drain
Max. input voltage V 30 Max. input current mA 27 Max. voltage drop at active output V/mA 2 / 27 Max. current through inactive output μA/V 5 / 30 Max. reverse voltage without destroying outputs V 6 (in case current does not exceed 27 mA) Pulse rates DN 50 l/pulse 1 / 10 / 100 / 1,000 (depending on nominal size) Pulse rates DN 65 - 150 l/pulse 10 / 100 / 1,000 (depending on nominal size) Pulse rates DN 200 l/pulse 100 / 1,000 (depending on nominal size) Configuration pulse output 1 Total volume or forward volume Configuration pulse output 2 Flow direction or error, reverse volume, forward volume Pulse frequency Max. frequency 10 Hz Pulse width 50 ms -
Available versions
Wireless M-Bus radio/Pulse/L-Bus 3 wires - only forward volume for pulse output 2 (minimum 10L/pulse) Wireless M-Bus radio only without wire Wired M-Bus/Pulse/Pulse 5 wires - forward volume on pulse output 1 and reverse volume on pulse output 2 Pulse (IZAR BE PULSE compatible) 4 wires - total volume on pulse output 1 and direction on pulse output 2 with fraud
-
Performance Data - Cold water (T30 / T50) Horizontal
Nominal diameter DN mm 50 65 80 100 125 150 200 Permanent flow rate Q3 m³/h 25 40 63 100 160 250 400 Dynamic (Q3/Q1) R 800 800 800 800 800 800 800 Overload flow rate Q4 m³/h 31.25 50 78.75 125 200 312.50 500 Transitional flow rate Q2 l/h 50 80 126 200 320 500 800 Minimum flow rate Q1 l/h 31.25 50 78.75 125 200 312.50 500 Starting flow rate l/h 15 27 35 45 70 250 400 Pressure loss at Q3 bar 0.16 0.15 0.16 0.13 0.15 0.11 0.12 Pressure loss at Q4 bar 0.25 0.23 0.25 0.2 0.23 0.18 0.19 Maximum flow rate 2 Qhigh m³/h 62.5 100 157.5 250 400 625 1000 Flow rate at ΔP = 1 bar m³/h 63 105 158 280 420 747 1140 2 Outlet pressure minimum 3 bar, maximum 100 hours per year, closed pipeline network -
Performance Data - Hot water (T90) Horizontal
Nominal diameter DN mm 50 65 80 100 125 150 200 Permanent flow rate Q3 m³/h 25 40 63 100 - - - Dynamic (Q3/Q1) R 400 400 400 400 - - - Overload flow rate Q4 m³/h 31.25 50 78.75 125 - - - Transitional flow rate Q2 l/h 100 160 250 400 - - - Minimum flow rate Q1 l/h 63 100 160 250 - - - Starting flow rate l/h 15 27 35 45 - - - Pressure loss at Q3 bar 0.16 0.15 0.16 0.13 - - - Pressure loss at Q4 bar 0.25 0.23 0.25 0.2 - - - Flow rate at ΔP = 1 bar m³/h 63 105 158 280 - - - -
Approval
Approval MID DE-19-MI001-PTB011 Dynamic range (Q3/Q1) R Up to R=1,000 Standards ISO 4064 | EN 14154 | OIML R49 Sanitary conformity ACS | WRAS | DM174 | BELGAQUA -
Dynamic Range
Q3 25 ... 400 m³/h - T30 R 800 Q3 25 ... 400 m³/h - T50 R 800H / 250V Q3 25 ... 100 m³/h - T90 R 400H / 160V H=horizontal installation position / V=vertical installation position -
Pressure loss graph / Typical error graph
-
Dimensions
Nominal diameter DN mm 50 65 80 100 125 150 200 Overall length (T30 / T50) L mm 200/ 270 / 3003 200 / 3003 200 / 225 / 300 / 3503 250 / 3504 / 360 250 300 / 500 350 Overall length (T90) L mm 200 200 200 / 225 250 - - - Flange diameter 5 D mm 165 185 200 220 250 285 340 Hole circle diameter 5 K mm 125 145 160 180 210 240 295 Number of screwholes 5 pcs 4 4 8 8 8 8 126 Screwhole diameter 5 D1 mm 19 19 19 19 19 23 23 Height H mm 74 87 95 105 120 135 161 Height H1 mm 121 143 147 165 177 185 215 Height H2 mm 61 61 61 61 61 61 61 Counter length L1 mm 98 98 98 98 98 98 98 Meter width B mm 165 185 200 220 250 285 340 Counter width B1 mm 139 139 139 139 139 139 139 Overall weight (approx.) kg 7 / 9 / 9 8 / 11 11 / 13 / 14 / 15 17 / 19 / 20 23 38 / 45 51 3 Optionally with rotatable flange
4 Rotatable flange
5 Flanges according to EN 1092, PN 10/16
6 8 Screwholes for PN 10 -
Meter body variants
a) The cold water meters come with an epoxy-coated cast iron housing as standard. ISO short length variants can optionally be manufactured with a stainless steel housing.
b) ISO long length meters with diameters up to DN 100 can optionally come with rotatable flanges.
c) Hot water meters are always provided with stainless steel housings (EN 1.4408, AISI 316). -
Reach
Information pursuant to Article 33 (1) of Regulation (EC) No 1907/2006 of the European Parliament and of the Council of 18 December
2006:
This product series contains articles with the following substances in a concentration of more than 0.1% weight by weight (w/w):
- Lead