ALTAIR V4 DN15/20

VOLUMETRIC METER

Application

ALTAIR V4 represents the latest generation of volumetric meters developed within the framework of the MID and European standards to meet field requirements. ALTAIR V4 is a particularly compact and robust meter, adapting to the most restrictive environments and compatible with varying water qualities.
Modular, ALTAIR V4 can be fitted at any time with an IZAR clip-on module converting it into a communicating meter, ready for mobile or fixed network (radio/wired) reading.

Features

  • DN15/20
  • Q3=2.5m3/h (DN15) / Q3=4m3/h (DN20)
  • MID approval up to R=800
  • Starting flowrate at 0.4 l/h
  • Composite & brass version
  • High dynamic range
  • Installation in any position
  • Optional dual-zone filter
  • Metrological data
    Nominal diametermm1515151515202020202020
    Length*Lmm110115134165170115165190110165190
    Nominal flow rateQ3m³/h2.52.52.52.52.52.52.52.5444
    R standard*Q3/Q1160160160160160160160160160160160
    Starting flow ratel/h0.40.40.40.40.40.40.40.40.70.70.7
    Minimum flow rate*Q1l/h15.6215.6215.6215.6215.6215.6215.6215.62252525
    Transition flow rate*Q2l/h2525252525252525404040
    Maximum flow rateQ4m3/h3.1253.1253.1253.1253.1253.1253.1253.125555
    Head loss at Q3bar0.590.590.590.590.590.590.590.590.550.550.55 / 0.57**
    Head loss at Q4bar0.920.920.920.920.920.920.920.920.850.850.85 / 0.89**
    Kvs (deltaP=Q²/Kvs²)3.253.253.253.253.253.253.253.255.415.415.41 / 5.30**
    * Other values on request
    ** Composite version
    *** Pressure loss at 2,500 l/h including dual check valve
    Note: the use of a dual-zone filter does not affect the head loss performance
  • Approval
    ApprovalsMID: LNE - 6250 / Type A2 | WATERMARK: WM040207 - NMI: P14/3/64
    StandardsISO 4064 | EN 14154 | OIML R49
    Sanitary conformity*ACS | WRAS | KTW | BELGAQUA | KIWA | DM 174 | ASNZ-4020
    * Dual-zone filter on request
  • REACH

    Information pursuant to Article 33 (1) of Regulation (EC) No 1907/2006 of the European Parliament and of the Council of 18 December 2006:
    This product series contains components with the following substances in a concentration of more than 0.1% weight by weight (w/w):
    - Lead (CAS no.: 7439-92-1)

  • Temperatures and pressure
    Water temperature°C0.1 ... +50
    Ambient operating temperature°C+1 ... +55
    Storage temperature°C-10 ... +55
    Nominal pressurePNbar16
  • Dimensions
    Nominal diametermm1515151515202020202020
    Length*Lmm110115134165170115165190110165190
    Nominal flow rateQ3m³/h2.52.52.52.52.52.52.52.5444
    Housingbrass /compositebrass /compositebrass /compositebrass /compositebrass /compositecompositebrass / compositebrassbrassbrassbrass /composite
    WidthBmm96.296.296.296.296.296.296.2909092.792.7
    HeightHmm104.4 / 109104.4 / 109104.4 / 109104.4 / 109104.4 / 109109104.4 / 109104.1131131131 / 134.8
    HeightH1mm26.7 / 2826.7 / 2826.7 / 2826.7 / 2826.7 / 282826.7 / 2826.116.616.616.6 / 20.4
    HeightH2mm77.7 / 8177.7 / 8177.7 / 8177.7 / 8177.7 / 818177.7 / 8178114.4114.4114.4
    Thread connectionsinch3/4"3/4" - 7/8"/3/4"3/4"3/4"3/4"1"1"1"1"1"1"
    Weightkg0.9 / 0.51 / 0.51 / 0.61 / 0.61 / 0.60.51 / 0.611.21.41.4 / 0.7
    * Other values on request.
    ** 1"28 BSW 14 TPI conform to AS 1722.2 Class B
  • Precision curve

    This technology does not require straight length.

  • Options

    - Non-return valve | - Pair of connectors | - Glass/metal register
    - Patented dual-zone filter. More efficient, it replaces glove finger filters. This new filter considerably slows down the aging of the meter.