VZO / VZF
INDUSTRIAL METER
Application
VZO is a volumetric meter with an oscillating piston. Its design makes it extremely rugged and highly accurate, even at low flowrates. VZO may be installed horizontally, vertically or at an angle. When used with burners, it may be fitted directly on the nozzle line. Its metering chamber can be easily cleaned without removing the meter from the pipe.
VZO is made of cast iron, bronze and aluminium piston and is particularly suitable for metering non-aggressive liquid lubricants such as fuel oil or mineral oil.
Modular, VZO may be fitted at any time with a pulse emitter. The variety of values and pulse types make VZO compatible with all centralised technical management systems. The version with an electronic register (VZF) offers a multifunctional display facility, as well as pulse and analogue outputs.
Features
- High measuring accuracy
- Smart meter
- From 1 to 5,000 mPa.S
- DN 15 to DN 50
- Fuel and oil measurement
- Metering in both flow directions
-
Technical characteristics
Nominal diameter DN mm 15 20 25 40 50 Nominal diameter DN inch 1/2 " 3/4 " 1 " 1-1/2 " 2 " Nominal pressure with threaded ends bar 16 16 16 16 16 Nominal pressure with flanges* bar 25 25 25 25 25 Maximum temperature* °C 130 130 130 130 130 Metering in both flow directions yes yes yes yes yes Maximum flow rate Qmax l/h 600 1,500 3,000 9,000 30,000 Permanent flow rate Qcont l/h 400 1,000 2,000 6,000 20,000 Minimum flow rate Qmin l/h 20 40 75 225 750 Starting flow rate l/h 4 12 30 90 300 Error tolerance of volume between Qmin and Qmax < ±1 % < ±1 % < ±1 % < ±1 % < ±1 % Repeatability < ±0.1 % < ±0.1 % < ±0.1 % < ±0.1 % < ±0.1 % Volume of the metering chamber (cyclical volume) cm³ 12 36 100 330 1,200 Verification step l 0.01 0.1 0.1 0.1 1 Recording capacity m³ 1,000 10,000 10,000 10,000 100,000 Max. recording time with continuous flow and no reset h 2,500 10,000 5,000 1,667 5,000 Width of the safety filter mesh mm 0.4 0.4 0.4 0.8 0.8 (*) Version up to 180°C also available. -
Pulse values for emitters (l/pulse)
Nominal diameter DN mm 15 20 25 40 50 IN (Inductive) K=10 0.01 0.01 0.1 0.1 1 IN (Inductive) K=1 0.1 0.1 1 1 10 RV (reed) K=1 0.1 1 1 1 10 RV (reed) K=10 1 - - 10 100 VZF programmable pulse max. freq. 100Hz max. freq. 100Hz max. freq. 100Hz max. freq. 100Hz max. freq. 100Hz VZF passive analogue output mA 4-20 4-20 4-20 4-20 4-20 -
Electronic register (VZF)
Displayed values Total volume, volume with reset, instant flowr ate value. Run time and other information in Service submenu. Display 8-segment LCD with parameter identification, 8-mm digit height, instant flow rate value (meter load) by a bar diagram. Temperature Ambient temperature -10°C to +70°C / Storage temperature -20°C to +80°C Safety EC, fatigue and impact resistance tests to DIN IEC 68 Power supply Standard lithium battery, CR 1 / 2AA or CR2 type Data backup Non volatile EEPROM memory Battery replacement After five years, on the basis of a six-year lifetime, with digital display of the instant value for 10 hours max. -
Dimensions : Body with threaded ends
Nominal diameter DN mm 15 20 25 40 50 Length a mm 165 165 190 300 Height under pipe b mm 45 54 77 116 Height c mm 20 20 24 37 Meter diameter Øf mm 105 105 130 210 Threads Øp inches 3/4" 1" 1-1/4" 2" Weight Kg 2.1 2.5 4.2 15.9 -
Dimensions : Body with flanges
Nominal diameter DN mm 15 20 25 40 50 Length a mm 165 165 190 300 350 Height under pipe b mm 45 54 77 116 166 Height c mm 20 20 24 37 43 Flanges diameter Øe mm 95 105 115 150 165 Meter diameter Øf mm 105 105 130 210 280 Weight kg 3.8 4.5 7.7 20.5 40 -
Assembly
Rotary piston meters may be fitted on horizontal or vertical pipes at an angle. They do not require the presence of straight lengths before or after the meter. The dial of the register must never be installed head down. Rotary piston meters are precision instruments and must always be protected by a filter. The mesh width must be less than 100 microns (0.1 mm).