SHARKY Solar 775
COMPACT ENERGY METER | ULTRASONIC
Application
The ultrasonic compact energy meter SHARKY Solar 775 can be used for measuring the energy consumption in solar systems.
Features
- Energy meter for the specific media TYFOCOR LS
- Available in the sizes qp 0.6 up to 2.5 m³/h
- Extremely low power consumption --> longer battery lifetime
- Insensitive against dirt
- Versatile possibility of power supply
- Optional with integrated radio, Real Data or Open Metering Standard (868 or 434 MHz)
- Individual remote reading (AMR) with add on modules Plug & Play
- Extensive readable data memory
- 3 communication interfaces (e. g. M-Bus + M-Bus + Radio)
- Significantly improved radio performance
-
General
Application Heating - cooling - heating/with cooling tariff Medium TYFOCOR LS Approval Without Accuracy ±10 % Mounting position flow sensor Any position, calming sections not necessary Protection class flow sensor Heating: IP 54; cooling and heating/with cooling tariff: acc. IP 68 Battery supply 3.6 VDC A-cell up to 10,5 years lifetime (depending on configuration); 3.6 VDC D-cell 16 years lifetime Mains supply 24 VAC; 230 VAC Temperature sensor type Pt 100 or Pt 500 with 2-wire leads; Ø 5.2 / 6 mm or direct sensor Cable length of temperature sensor Pt 100: 1.9 m; Pt 500: 1.9 / 2.9 / 4.9 / 9.9 m Volume measuring cycle With mains unit: ⅛ s; with A-cell battery: 1 s; with D-cell battery: 1 s Test possibilities Via display, optical test pulses, test output or via NOWA software Material of the flow sensor body Brass -
Reach
Information pursuant to Article 33 (1) of Regulation (EC) No 1907/2006 of the European Parliament and of the Council of 18 December 2006:
This product series contains components with the following substances in a concentration of more than 0.1% weight by weight (w/w):
- Lead (CAS no.: 7439-92-1)
- Lead titanium zirconium oxide (CAS no.: 12626-81-2) -
Calculator - Basic features
Environmental class Class C Ambient class Class E2 + M2 Ambient temperature °C 5 ... 55 Ambient storage temperature °C -25 ... +60 (>35 °C max. 4 weeks) Protection class IP 54 Communication 3 communication interfaces (e. g. M-Bus + M-Bus + integr. radio; 2 primary adresses, 1 secondary adress) Integrated Radio Optional Interfaces standard Optical ZVEI interface Interfaces optional 2 Slots for modules with M-Bus, L-Bus, RS232, RS485, pulse output, pulse input, combined pulse in-/output or analogue output Temperature range °C 5 ... 130 Extensive readable data memory Periodical log1; history log; event memory 1 Programmable storage interval (daily, weekly, monthly, ...) -
Calculator - Integrated Radio
Frequency band 868 or 434 MHz Type of radio telegram Real Data or Open Metering Standard (OMS) Transmission data updating Online - no time delay between value measurement and data transmission Data transmission Unidirectional Sending interval With A-cell: 180 s (11 years lifetime); with D-cell: 12 s (16 years lifetime); with mains unit: 12 s; depending on length of telegram (duty cycle) -
Display
Display indication LCD, 8-digit Units MWh - kWh - GJ - Gcal - MBtu Total values 99,999,999 - 9,999,999.9 - 999,999.99 - 99,999.999 Values displayed Energy - Power - Volume - Flow rate - Temperature and more -
Interfaces
Optical ZVEI interface, for communication and testing, M-Bus protocol M-Bus Configurable telegram, according to EN13757-3, two wires with non polarity, auto baud detect (300 and 2400 baud), 2 M-Bus with 2 primary adresses L-Bus Adapter for external radio module, configurable telegram, according to EN13757-3, data reading and parametrization are via two wires with polarity reversal protection RS232 Serial interface for communication with external devices, a special data cable is required, M-Bus protocol, 300 and 2400 baud RS485 Serial interface for communication with external devices, power supply with 12 V ± 5 V, M-Bus protocol, 2400 baud Pulse output Module with 2 Open Collector pulse outputs (potential-free), output 1: 4 Hz (pulse width 125 ms), pulse or static conditions (e.g. errors), output 2: 2000 Hz (pulse width ≥ 5 ms), ratio: pulse duration / pulse break ~ 1:1, configurable via IZAR@MOBILE 2 software. Pulse input Module with 2 pulse inputs, max. 20 Hz, configurable via IZAR@MOBILE 2 software, data can be transferred remotely Combined pulse in-/output Module with 2 pulse inputs and 1 pulse output, configurable via IZAR@MOBILE 2 software, needed for leak detection Analogue output Module for 4 ... 20 mA with 2 programmable passive outputs, programmable value in case of error -
Temperature input
Sensor current mA Pt 100 peak < 8; rms < 0.015, Pt 500 peak < 2; rms < 0.012 Measuring cycle T s With mains unit: 2 s; with A-cell battery: 16 s; with D-cell battery: 4 s Starting temperature difference ΔΘ K 0.125 Min. temperature difference ΔΘmin K 3 Max. temperature difference ΔΘmax K 127 Absolute temperature measuring range Θ °C 0 ... 130 -
Technical data flow sensor
Nominal flow rate qp m³/h 0.6 0.6 0.6 1.5 1.5 1.5 2.5 2.5 Nominal diameter DN mm 15 20 20 15 20 20 20 20 Overall length L mm 110 130 190 110 130 190 130 190 Starting flow rate l/h 1 1 1 2.5 2.5 2.5 4 4 Minimum flow rate qi l/h 6 6 6 6 6 6 10 10 Maximum flow rate qs m3/h 1.2 1.2 1.2 3 3 3 5 5 Overload flow rate m3/h 2.5 2.5 2.5 4.6 4.6 4.6 6.7 6.7 Operating pressure PN bar 161 161 161 161 161 161 161 161 Pressure loss at qp Δp mbar 95 85 85 120 75 75 100 100 Temp. range °C 5 ... 130 5 ... 130 5 ... 130 5 ... 130 5 ... 130 5 ... 130 5 ... 130 5 ... 130 Kvs value (Δp=Q2/Kvs2) 2.06 2.06 2.06 5.48 5.48 5.48 7.91 7.91 1 Also available in PN 25 bar -
Dimensions thread version
Nominal flow rate qp m³/h 0.6 0.6 0.6 1.5 1.5 1.5 2.5 2.5 Nominal diameter DN mm 15 20 20 15 20 20 20 20 Overall length L mm 110 130 190 110 130 190 130 190 Overall length with coupling L2 mm 190 230 290 190 230 290 230 290 Length of calculator L1 mm 150 150 150 150 150 150 150 150 Height H mm 14.5 18 18 14.5 18 18 18 18 Height H1 mm 82 84 84 82 84 84 84 84 Height of calculator H2 mm 54 54 54 54 54 54 54 54 Width of calculator B mm 100 100 100 100 100 100 100 100 Connection thread on meter Inch G¾B G1B G1B G¾B G1B G1B G1B G1B Connection thread of coupling Inch R½ R¾ R¾ R½ R¾ R¾ R¾ R¾ Weight1 kg 0.76 0.85 0.96 0.76 0.85 0.96 0.85 0.96 1 Meter with A-cell, without modules, 1.4 m cable length, 1.9 m cable length of temperature sensor Ø 5.2 mm -
Dimensions flange version
Nominal flow rate qp m³/h 0.6 0.6 0.6 1.5 1.5 1.5 2.5 2.5 Nominal diameter DN mm 15 20 20 15 20 20 20 20 Overall length L mm 110 130 190 110 130 190 130 190 Length of calculator L1 mm - - 150 - - 150 - 150 Height H mm - - 47.5 - - 47.5 - 47.5 Height H1 mm - - 84 - - 84 - 84 Height of calculator H2 mm - - 54 - - 54 - 54 Width of calculator B mm - - 100 - - 100 - 100 Flange dimension F mm - - 95 - - 95 - 95 Flange diameter D mm - - 105 - - 105 - 105 Hole circle diameter K mm - - 75 - - 75 - 75 Screwhole diameter D1 mm - - 14 - - 14 - 14 Number of screwholes pcs - - 4 - - 4 - 4 Weight1 kg - - 2.75 - - 2.75 - 2.75 1 Meter with A-cell, without modules, 1.4 m cable length, 1.9 m cable length of temperature sensor Ø 5.2 mm -
Pressure loss graph