SHARKY 774 compact
ULTRASONIC COMPACT ENERGY METER
Application
SHARKY 774 COMPACT ultrasonic energy meter is designed for measuring the energy consumption in heating or bifunctional (heating/cooling) application for billing purposes. Its static ultrasonic technology is based on the measurement of the transit time. It offers many benefits: no moving parts (reduces wear and tear of the metering components), low pressure loss, wide dynamic measuring range, low start flowrate and insensitiveness to suspended particles.
Features
- M-Bus or Wireless M-Bus (OMS radio 868 MHz) communication. Enhanced transmission performance is achieved when combined with Diehl Metering AMR system technology
- Heat-transfer fluid: water
- Constant high measuring rates of the temperatures and volume with up to 12 years battery life time
- 8-digit LCD
- Removable calculator (0.45m coaxial cable) ensuring comfortable reading
-
General
Application Heating or bifunctional (heating /cooling) | Heat-transfer fluid: glycol-free water Approval MID (DE-13-MI004-PTB008) Environmental class Class 2 Ambient class Class E2 + M2 Ambient operating temperature °C +5 ... +55 (<35 °C have a positive effect on battery lifetime) Ambient storage temperature °C -25 ... +60 (>35 °C max. 4 weeks) Communication M-Bus or radio Frequency band 868 or 434 MHz Type of radio telegram Open Metering Standard (OMS) Transmission data updating Online - no time delay between value measurement and data transmission Data transmission Unidirectional Sending interval Rapid mode (drive-by): 14 s + synchron telegram: 900 s | standard mode (walk-by): 64 s + synchron telegram: 900 s -
-
Calculator - basic features
Protection class IP 65 Battery supply 3.6 VDC (2xAA-cell), up to 12 years lifetime (at standard conditions of use and temperature) Battery1 lifetime - radio Rapid mode: up to 7 years; standard mode: up to 11 years (depends on sending interval) Battery1 lifetime - M-Bus Up to 12 years Temperature sensor type Pt 500, 2-wire; Ø 5.2 mm Cable length of temperature sensor m 1.45 / 1.95 Absolute temperature range Θ °C +1 ... +105 (+130 in option) Measuring cycle - flow s 2 Measuring cycle - temperature sensor s 16 Starting temperature difference ΔΘ K 0.125 Min. temperature difference ΔΘmin K 3 (MID approved) Max. temperature difference (heating) ΔΘmax K 127 (MID approved) Interfaces standard Optical ZVEI interface Interfaces optional M-Bus or radio Extensive readable data memory Periodical log2; 3 history logs; event memory 1 Battery exchangeable at lab
2 Programmable storage interval (daily, weekly, monthly, ...) -
Flow sensor - basic features
Protection class flow sensor IP54 (heating) - IP68 (heating/cooling) Material of the flow sensor body Brass Temperature range heating °C +5 ... +105* +5 ... +105 Temperature range heating with cooling tariff °C 5 ... 105 Dynamic range (qp/qi) 1:100 Mounting position flow sensor Any position, calming section not necessary * +130°C in option -
Display
Display indication LCD, 8-digit Units MWh - kWh - GJ - °C - m³ Total values 99,999,999 - 9,999,999.9 - 999,999.99 - 99,999.999 Values displayed Energy - Power - Volume - Flow rate - Temperature and more * MWh - GJ in option -
Interfaces
Optical ZVEI interface, for communication and testing, M-Bus protocol M-Bus Configurable telegram, according to EN13757-3, data reading via two wires with non polarity (1.5 m), auto baud detect (300 and 2400 baud), galvanically isolated, one M-Bus load Wireless M-Bus Open Metering Standard (OMS), Generation 3 Profile A or Generation 4 Profile B; frequency band 868 or 434 MHz -
Technical data flow sensor
Nominal flow rate qp m³/h 1.5 2.5 Nominal diameter DN mm 15 20 Overall length L mm 110 130 Starting flow rate l/h 2.5 4 Minimum flow rate qi l/h 15 25 Maximum flow rate qs m³/h 3 5 Overload flow rate m³/h 4.6 6.7 Operating pressure PN bar 16 16 kv value (qp² (m³/h) = kv² x Δp (bar)) 4.33 7.91 Pressure loss at qp Δp mbar 120 100 -
Dimensions thread version
Nominal flow rate qp m³/h 1.5 2.5 Nominal diameter DN mm 15 20 Overall length L mm 110 130 Overall length with coupling L2 mm 190 230 Length of calculator L1 mm 90 90 Height H mm 14.5 18 Height H1 mm 55 58 Height of calculator H2 mm 27 27 Height of calculator H3 mm 40 40 Width of calculator B mm 135 135 Connection thread on meter inch G¾B G1B Connection thread of coupling inch R½ R¾ Weight kg 0.70 0.77 -
Pressure loss graph / Typical error graph