AQUILA V5
SINGLE-JET METER
AQUILA V5 is a bulk water meter designed for water network management and invoicing of substantial quantities of cold water.
It is characterised by its very high measuring dynamic, insensitivity to disturbance and easy maintenance. Its modular rotating flanges make it easy to install on any type of pipe, even when resizing is necessary.
Developed within the framework of the MID, AQUILA V5 complies with the European regulations and holds sanitary conformity certificates.
AQUILA V5 can be fitted at any time with an IZAR clip-on module converting it into a communicating meter ready for mobile reading (walk-by, drive-by, passive drive-by) or fixed network reading (radio/wired).
- DN50/65/80/100
- Q3=25m3/h (DN50) / Q3=40m3/h (DN65) / Q3=63m3/h (DN80) / Q3=100m3/h (DN100)
- MID approval up to R=800
- Starting flow rate: 18 l/h (DN50)
- Cast-iron body
-
Metrological data
Nominal diameter DN mm 50 65 80 100 Length L mm 300 300 350 350 Nominal flow rate Q3 m3/h 25 40 63 100 R standard* Q3/Q1 315 315 315 315 Starting flow rate l/h 18 28 31 38 Minimum flow rate Q1 l/h 80 127 200 317 Transition flow rate Q2 l/h 127 203 320 508 Maximum flow rate Q4 m³/h 31.25 50 78.75 125 Head loss at Q3 bar 0.47 0.61 0.43 0.60 Head loss at Q4 bar 0.74 0.99 0.77 0.92 Kvs (deltaP=Q²/Kvs²) 36.38 50.23 89.63 130.18 * other values on request -
Approval
MID approval LNE - 10913 | C1 type Standards EN 14154 | ISO 4064 | OIML R49 Sanitary conformity ACS | WRAS | PZH -
Temperature and pressure
Water temperature °C 0.1 ... +50 Ambient operating temperature °C 1 ... +55 Storage temperature °C -10 ... +55 Nominal pressure PN bar 16 (additional PN20 for DN50) - Dimensions
-
Available flanges
Nominal diameter DN mm 50 65 80 100 Length L mm 300 300 350 350 Flanges DN50 PN16 • - - - Flanges DN50 PN20 • - - - Flanges DN60-65 PN16 • • - - Flanges DN80 PN16 - • • - Flanges DN100 PN16 - - • • - Precision curve
-
Options
- Pressure connector
- Different types of flanges