ALTAIR V5 DN15/20

ROTARY PISTON METER

Application

ALTAIR V5 represents the latest generation of volumetric meters developed within the framework of the MID and European standards to meet field requirements. ALTAIR V5 is a particularly compact and robust meter, adapting to the most restrictive environments and compatible with varying water qualities. Modular ALTAIR V5 can be fitted at any time an IZAR clip-on module converting it into a communicating meter, ready for mobile or fixed network (radio/wired) reading.

Features

  • DN 15 / DN 20
  • Q3 = 1.6 m³/h (DN 15) / Q3 = 2.5 m³/h (DN 15 and DN 20) / Q3 = 4 m³/h (DN 20)
  • MID approval up to R=1000
  • Starting flowrate at <0.2 l/h (DN 15) / 0.4 l/h (DN 20)
  • Composite and brass version
  • High dynamic range
  • Installation in any position
  • Metrological data
    Nominal diameterDNmm15152020202020
    Length1Lmm110110190130165175190
    Permanent flow rateQ3m3/h1.62.52.54444
    R standard1Q3/Q1160160160160160160160
    Starting flow ratel/h<0.2<0.20.40.40.40.40.4
    Minimum flow rate1Q1l/h1015.6215.6225252525
    Transitional flow rate1Q2l/h16252540404040
    Overload flow rateQ4m3/h23.133.135555
    Head loss at Q3bar0.250.57 / 0.5320.22 / 0.2420.560.56 / 0.6220.560.56 / 0.622
    Head loss at Q4bar0.380.86 / 0.8520.35 / 0.3820.870.87 / 0.9820.870.87 / 0.982
    kvs (deltaP=Q²/Kvs²)3.243.34 / 3.4125.33 / 5.0725.355.35 / 5.0625.355.35 / 5.062
    1 Other values on request
    2 Composite version
    3 Pressure loss at 2,500 l/h including dual check valve
  • Approval
    ApprovalsMID: LNE - 39018 / Type A3 | WATERMARK: WM040207 - NMI: P14/3/76
    StandardsISO 4064 | EN 14154 | OIML R49
    Sanitary conformityACS | AoC DEU | Belgaqua | DM 174 | OTH (DN20) | PZH | WRAS | ASNZ - 4020
  • REACH

    Information pursuant to Article 33 (1) of Regulation (EC) No 1907/2006 of the European Parliament and of the Council of 18 December 2006:
    This product series contains components with the following substances in a concentration of more than 0.1% weight by weight (w/w):
    - Lead (CAS no.: 7439-92-1)

  • Temperatures and pressure
    Water temperature°C0.1 ... +50
    Ambient operating temperature°C+1 ... +55
    Storage temperature°C-10 ... +55
    Nominal pressurePNbar16
  • Dimensions
    Nominal diameterDNmm15152020202020
    Length1Lmm110110190130165175190
    Permanent flow rateQ3m3/h1.62.52.54444
    Housingbrassbrass / compositebrass / compositebrassbrass / compositebrassbrass / composite
    WidthBmm83.583.5 / 8791.3 / 9591.391.3 / 9591.391.3 / 95
    HeightHmm110.1110.1 / 110.9124.4 / 127.7124.4124.4 / 127.7124.4124.4 / 127.7
    HeightH1mm14.814.8 / 15.518.5 / 19.118.518.5 / 19.118.518.5 / 19.1
    HeightH2mm95.395.3 / 95.4105.9 / 108.6105.9105.9 / 108.6105.9105.9 / 108.6
    Thread connectionsinchG¾BG¾BG1BG1BG1BG1¼BG1B
    Weightkg0.620.62 / 0.331.04 / 0.470.930.96 / 0.461.051.04 / 0.47
    1 Other values on request
    2 1"28 BSW 14 TPI conform to AS 1722.2 Class B
    3 Lead free + DZR
  • Precision curve

    This technology does not require straight length.

  • Options

    - Non-return valve
    - Pair of connectors
    - Glass/metal register