SHARKY Solar 775
ULTRASONIC COMPACT ENERGY METER
Application
SHARKY SOLAR 775 is a ultrasonic compact energy meter designed for measuring the energy consumption in solar systems. The measurement principle is static and based on the measurement of the transit time. Ultrasonic technology offers many benefits : no moving parts (prevents wear and tear of the metering components), low pressure loss, large metering dynamics and low start flowrate, insensitiveness to suspended particles...
Features
- Designed for the specific heat transfer fluid TYFOCOR LS
- Available in DN 15 and 20
- Low power consumption enabling a long battery lifetime (up to 16 years)
- Integrated radio option
- Modular version, M-Bus, RS232, RS485, Analog outputs 4-20mA, pulse outputs and inputs
-
General
Application Heating - heating with cooling tariff Medium TYFOCOR LS Approval - Accuracy ±10 % Mounting position flow sensor Any position, no straight length Protection class flow sensor Heating: IP 54 | Heating with cooling tariff : IP 65 Battery supply 3.6 VDC D-cell (up to 16 years lifetime*) Mains supply 24 VAC; 230 VAC Temperature sensor type Pt 500 with 2-wire leads; Ø 5.2 direct sensor Cable length of temperature sensor Pt 500: 2 / 3 / 5 / 10 m Volume measuring cycle With mains unit: ⅛ s | with D-cell battery: 1 s Test possibilities Via display, optical test pulses, test output or via NOWA software Material of the flow sensor body Brass * Standard conditions of use and temperature. Theoretical life, with no guarantee. -
-
Calculator - Basic features
Environmental class Class C Ambient class Class E2 + M2 Ambient temperature °C +5 ... +55 Ambient storage temperature °C -25 ... +60 (>35 °C max. 4 weeks) Protection class IP 54 Communication 3 communication interfaces (e. g. M-Bus + M-Bus + integr. radio; 2 primary addresses, 1 secondary address) Integrated Radio Optional Interfaces standard Optical ZVEI interface Interfaces optional 2 Slots for modules M-Bus, RS232, RS485, pulse output, pulse input, combined pulse in-/output or analogue output Temperature range °C +5 ... +130 Extensive readable data memory Periodical log1 | history log | event memory 1 Programmable storage interval (daily, weekly, monthly, ...) -
Calculator - Integrated Radio
Frequency band 868 or 434 MHz Type of radio telegram Real Data or Open Metering Standard (OMS) Transmission data updating Online Data transmission Unidirectional Sending interval 12 s (up to 16 years lifetime*) depending on length of telegram (duty cycle) * Standard conditions of use and temperature. Theoretical life, with no guarantee. -
Display
Display indication LCD, 8-digit Units MWh - kWh - GJ - Gcal - MBtu - gal - GPM - °C - °F - m³ - m³/h Display capacity 99,999,999 - 9,999,999.9 - 999,999.99 - 99,999.999 (depending on the nominal diameter) Values displayed Energy - Volume - Flow rate - Power - Temperature -
Interfaces
Optical ZVEI interface, for communication and testing, M-Bus protocol M-Bus Configurable telegram, according to EN13757-3, data reading and parametrization via 2 wires with polarity reversal protection, auto baud detect (300 and 2,400 baud), 2 M-Bus outputs with 2 primary addresses L-Bus Adapter for external radio module, configurable telegram, according to EN13757-3, data reading and parametrization via 2 wires with polarity reversal protection RS232 Serial interface for communication with external devices, a special data cable is required, M-Bus protocol, 300 and 2,400 baud RS485 Serial interface for communication with external devices, power supply with 12 V ± 5 V, M-Bus protocol, 2,400 baud Pulse output Module with 2 Open Collector pulse outputs (potential-free), output 1: 4 Hz (pulse width 125 ms) pulse or static conditions (e.g. errors) | output 2: 200 Hz (pulse width ≥ 5 ms), ratio: pulse duration/pulse break ~ 1:1, configurable via IZAR@MOBILE 2 software Pulse input Module with 2 pulse inputs, max. 20 Hz, configurable via IZAR@MOBILE 2 software, data can be transferred remotely Combined pulse in-/output Module with 2 pulse inputs and 1 pulse output, configurable via IZAR@MOBILE 2 software, needed for leak detection Analogue output Module for 4 ... 20 mA with 2 programmable passive outputs, programmable value in case of error -
Temperature input
Measuring cycle T s With main units: 2 s | with D-cell battery: 4 s Starting temperature difference ΔΘ K 0.125 Min. temperature difference ΔΘmin K 3 Max. temperature difference ΔΘmax K 175 Absolute temperature measuring range Θ °C 0 ... +130 -
Technical data flow sensor
Nominal flow rate qp m³/h 1.5 2.5 Nominal diameter DN mm 15 20 Overall length L mm 110 130 Starting flow rate l/h 2.5 4 Minimum flow rate qi l/h 6 10 Maximum flow rate qs m3/h 3 5 Overload flow rate m3/h 4.6 6.7 Operating pressure PN bar 16 16 Pressure loss at qp Δp mbar 75 100 Temp. range °C +5 ... +130 +5 ... +130 Kvs value (Δp=Q2/Kvs2) 5.48 7.91 -
Dimensions thread version
Nominal flow rate qp m³/h 1.5 2.5 Nominal diameter DN mm 15 20 Overall length L mm 110 130 Overall length with coupling L2 mm 190 230 Length of calculator L1 mm 150 150 Height H mm 14.5 18 Height H1 mm 82 84 Height of calculator H2 mm 54 54 Width of calculator B mm 100 100 Connection thread on meter Inch G¾B G1B Connection thread of coupling Inch R½ R¾ Weight kg 0.76 0.85 -
Pressure loss graph