ALTAIR V5 DN15/20

VOLUMETRIC METER

Application

ALTAIR V5 represents the latest generation of volumetric meters developed within the framework of the MID and European standards to meet field requirements. ALTAIR V5 is a particularly compact and robust meter, adapting to the most restrictive environments and compatible with varying water qualities. Modular ALTAIR V5 can be fitted at any time an IZAR clip-on module converting it into a communicating meter, ready for mobile or fixed network (radio/wired) reading.

Features

  • DN15 / DN20
  • Q3 = 1.6 m3/h (DN15) / Q3 = 2.5 m3/h (DN15 and DN20) / Q3 = 4 m3/h (DN20)
  • MID approval up to R=1000
  • Starting flowrate at <0.2 l/h (DN15) / 0.4 l/h (DN20)
  • Brass version (DN15 and DN20) and Composite version (DN20)
  • High dynamic range
  • Installation in any position
  • Metrological data
    Nominal diametermm1515151515152020202020202020
    Length1Lmm110110115145165170110165190110130165175190
    Nominal flow rateQ3m3/h1.62.52.52.52.52.52.52.52.544444
    R standard1Q3/Q1160160160160160160160160160160160160160160
    Starting flow ratel/h<0.2<0.2<0.2<0.2<0.2<0.20.40.40.40.40.40.40.40.4
    Minimum flow rate1Q1l/h1015.6215.6215.6215.6215.6215.6215.6215.622525252525
    Transition flow rate1Q2l/h1625252525252525254040404040
    Maximum flow rateQ4m3/h23.133.133.133.133.133.133.133.1355555
    Head loss at Q3bar0.250.570.570.570.570.570.220.220.220.560.560.56/0.6220.560.56/0.622
    Head loss at Q4bar0.380.860.860.860.860.860.350.350.350.870.870.87/0.9820.870.87/0.982
    kvs (deltaP=Q²/Kvs²)3.243.343.343.343.343.345.335.335.335.355.355.35/5.0625.355.35/5.062
    1 Other values on request
    2 Composite version
    3 Pressure loss at 2,500l/h including dual check valve
  • Approval
    ApprovalsMID: LNE - 39018 / Type A3 | WATERMARK: WM040207 - NMI: P14/3/76 | UKCA
    StandardsISO 4064 | EN 14154 | OIML R49
    Sanitary conformityACS | AoC DEU | Belgaqua | DM 174 | OTH (DN20) | PZH | WRAS | ASNZ - 4020
  • REACH

    Information pursuant to Article 33 (1) of Regulation (EC) No 1907/2006 of the European Parliament and of the Council of 18 December 2006:
    This product series contains components with the following substances in a concentration of more than 0.1% weight by weight (w/w):
    - Lead (CAS no.: 7439-92-1)

  • Temperatures and pressure
    Water temperature°C0.1 ... +50
    Ambient operating temperature°C+1 ... +55
    Storage temperature°C-10 ... +55
    Nominal pressurePNbar16
  • Dimensions
    Nominal diametermm1515151515152020202020202020
    Length1Lmm110110115145165170110165190110130165175190
    Nominal flow rateQ3m3/h1.62.52.52.52.52.52.52.52.544444
    Housingbrassbrassbrassbrassbrassbrassbrassbrass/compositebrass/compositebrassbrassbrass/compositebrassbrass/composite
    WidthBmm83.583.583.583.583.583.591.391.3/9591.3/9591.391.391.3/9591.391.3/95
    HeightHmm110.1110.1110.4110.1110.1110.1124.4124.4/127.7124.4/127.7124.4124.4124.4/127.7124.4124.4/127.7
    HeightH1mm14.814.815.114.814.814.818.518.5/19.118.5/19.118.518.518.5/19.118.518.5/19.1
    HeightH2mm95.395.395.395.395.395.3105.5105.9/108.6105.9/108.6105.9105.9105.9/108.6105.9105.9/108.6
    Thread connectionsinch3/4"3/4"3/4" - 7/8"3/4"3/4"3/4"1"1"1"1"1"1"1" 1/41"
    Weightkg0.620.620.630.660.680.690.910.96/0.461.04/0.470.910.930.96/0.461.051.04/0.47
    1 Other values on request
    2 1"28 BSW 14 TPI conform to AS 1722.2 Class B
    3 Lead free + DZR
  • Precision curve

    This technology does not require straight length.

  • Options

    Non-return valve | Pair of connectors | Glass/metal register