SHARKY FS 473

分体式超声波热量表

Application

The ultrasonic flow sensor can be used for flow measuring in local and district heating / cooling systems.

Features

  • 1st approval in Europe for ultrasonic flow sensor with a dynamic range (DR) of up to 1:250 (qi:qp) in class 2 (depends on meter size), standard 1:100
  • Extreme low power consumption --> longer battery lifetime
  • Approved according EN 1434 and MID in class 2 and 3 and PTB K 7.2 (cooling)
  • High long term stability, verified with independent AGFW test
  • Applicable for different calculators with impulse input
  • Free selectable impulse values, time continuously pulse, no puls packages
  • The temperature range depending on the applicaton 5 ... 150 °C
  • Battery or external power supply
  • Specific housing for falling and rising pipes
  • General
    ApplicationHeating - cooling
    ApprovalMID and PTB K 7.2 for cooling
    Ambient classEN 1434 class C / MID class E2 + M2
    Ambient temperature°C5 ... 55
    Power supply3.0 VDC battery - up to 12 years lifetime; external supply 3.0 ... 5.5 VDC
    Mounting positionAny position
    Protection classHeating: IP 54; cooling: IP 65
    InterfacesOpen Collector pulse output1 - output for testing and communication2
    Volume pulse value310 ml ... 5000 l/pulse (depending on sensor sizes and supply)
    Cable length of impulse cable10 m
    Material of the flow sensor bodyBrass (qp 0.6 ... 10 m³/h), grey cast iron (qp 15 ... 60 m³/h)
    1 The pulse output can be choosen without galvanic isolation (standard) or with galvanic isolation (only with battery supply). The flow sensor has by default a 4-wire impulse cable.
    2 The output for testing is a combined pulse output. The flow sensor can either emit a high resolution test pulse (standard) or communicate via the same output. By using an adapter the flow sensor can be read via the HYDRO-SET software.
    3 The pulse duration is between 1 and 250 ms. It depends on the pulse value and on the nominal flow rate qp.
    Standard pulse values: 1, 2.5, 10, 25, 100, 250 l/pulse
  • Temperature range
    Temperature range heating - battery supplied°C5 ... 90 / 5 ... 1051
    Temperature range heating - external supplied°C5 ... 130 / 150
    Temperature range cooling - battery supplied°C5 ... 90 / 5 ... 1051
    1 Only in rising or falling pipes or tilted horizontal installation
  • Technical data
    Nominal flow rateqpm3/h0.60.60.61.51.51.52.52.53.53.53.53.53.5666666101015254060100
    Nominal diameterDNmm1520 20 15 20 20 20 20 25 25 2532 32 25 25 2532 324040 40 50 6580100125
    Overall lengthLmm 110 130 190 110 130 190 130 190135150 260150 260135150 260150 260150200 300 270 300300360360
    Starting flow ratel/h1112.52.52.54410101010101010101010102020405080120120
    Minimum flow rate (DR 1:250)qil/h 6 6 6 6 6 6 1010-----24242424 24-401401601100116012401-
    Minimum flow rate (DR 1:100)qil/h66615151525253535353535606060606060100100150250400600/120021000
    Minimum flow rate (up side down installation)qil/h66666610103535353535242424242410010015025040012001200
    Maximum flow rateqsm³/h 1.2 1.2 1.2 3 3 3 5 5 7 7 7 7 7 12 12 12 12 12122020305080120120
    Overload flow ratem³/h 2.5 2.5 2.5 4.6 4.6 4.6 6.7 6.7 18.4 18.4 18.4 18.4 18.4 18.4 18.4 18.4 18.4 18.418.424 24 36 6090132132
    Pressure loss at qpΔpmbar9585851207575100100444460656019012812819016519014014014075807580
    Temp. range heating°C5 ... 1305 ... 1305 ... 1305 ... 1305 ... 1305 ... 1305 ... 1305 ... 1305 ... 1505 ... 1505 ... 1505 ... 1505 ... 1505 ... 1505 ... 1505 ... 1505 ... 1505 ... 1505 ... 1505 ... 1505 ... 1505 ... 1505 ... 1505 ... 1505 ... 1505 ... 150
    Kvs value (qp2 (m3/h) = Kvs2 x Δp (bar))1.952.062.064.335.485.487.917.9116.6916.6914.2913.7314.2913.7616.7716.7713.7614.7713.7626.7326.7340.0991.29141.42219.09218.22
    1 Valid for horizontal installation only
    2 Up side down installation
  • Dimensions thread version
    Nominal flow rateqpm3/h0.60.60.61.51.51.52.52.53.53.53.53.53.5666666101015254060100
    Nominal diameterDNmm1520 20 15 20 20 20 20 25 25 2532 32 25 25 2532 324040 40 50 6580100125
    Overall lengthLmm 110 130 190 110 130 190 130 190135150 260150 260135150 260150 260150200 300 270 300300360360
    Overall length with couplingL2mm190230-190230-230-255270380270380255270380270380-340440-----
    HeightHmm 14.5181814.51818181823232323232323232323333333-----
    HeightH1mm 54.556.556.554.556.556.556.556.5616161616161616161616166.566.5-----
    Length of electronicL1mm 909090909090909090909090909090909090909090-----
    Width of electronicBmm65.565.565.565.565.565.565.565.565.565.565.565.565.565.565.565.565.565.565.565.565.5-----
    Connection thread on meterInchG¾BG1BG1BG¾BG1BG1BG1BG1BG1¼BG1¼BG1¼BG1½BG1½ BG1¼BG1¼BG1¼BG1½BG1½ BG2BG2BG2B-----
    Connection thread of couplingInchR1R1R1R1¼R1¼R1R1R1R1¼R1¼R1½R1½R1½-----
    Operating pressurePNbar16/2516/2516/2516/2516/2516/2516/2516/2516/2516/2516/2516/2516/2516/2516/2516/2516/2516/2516/2516/2516/25-----
    Weightkg0.60.610.630.60.610.630.610.630.880.931.351.081.350.880.931.351.081.351.522.42.6-----
  • Dimensions flange version
    Nominal flow rateqpm3/h0.60.60.61.51.51.52.52.53.53.53.53.53.5666666101015254060100
    Nominal diameterDNmm1520 20 15 20 20 20 20 25 25 2532 32 25 25 2532 324040 40 50 6580100125
    Overall lengthLmm 110 130 190 110 130 190 130 190135150 260150 260135150 260150 260150200 300 270 300300360360
    HeightHmm--47.5--47.5-47.5--50-62.5--50-62.5--6973.58592.5108127.5
    HeightH1mm--56.5--56.5-56.5--61-61--61-61--66.571.57986.596.596.5
    Length of electronicL1mm--90--90-90--90-90--90-90--909090909090
    Width of electronicBmm--65.5--65.5-65.5--65.5-65.5--65.5-65.5--65.565.565.565.565.565.5
    Flange dimensionFmm--95--95-95--100-125--100-125--138147170185216255
    Flange diameterDmm--105--105-105--114-139--114-139--148163184200235270
    Hole circle diameterKmm--75--75-75--85-100--85-100--1101251451601801 / 190220
    Screwhole diameterD1mm--14--14-14--14-18--14-18--18181819191 / 2226
    Operating pressurePNbar--16/25--16/25-16/25--16/25-16/25--16/25-16/25--16/2516/25/40316/25/40316/25/40316/25/40325
    Number of screwholespcs--4--4-4--4-4--4-4--448888
    Weight brass body2kg--2.7--2.7-2.7--3.35-4.65--3.35-4.65--6.67.459.4511.116.921.85
    Weight grey cast iron body2kg---------------------6.318.0810.0115.76-
    1 Values for PN 16 housing
    2 Meter with battery and 10 m cable length of the pulse cable
    3 Only for brass body
  • Pressure loss graph / typical error graph