CORONA DP 405

MULTI-JET METER | DRY RUNNER

Application

Contact water meter for proportional control of pumps, motors, etc.
Metering with digital preselection of quantity and remote transmission of flow rates.

Features

  • Multi-jet impeller meter in completely dry-running design with magnetic coupling
  • Only the impeller operates in the wet chamber to prevent faults due to sediment
  • Encapsulated waterproof counter. Reading not obstructed by condensation of the transparent cover
  • Counter can be rotated to any position for easy reading
  • Built-in pulse contact (with cable 2 m) cast in a waterproof enclosure and easily replaceable
  • Max. contact load 24 V (SELV) 0.2 A
  • The outlet is prepared for installing a non-return valve (DVGW approved)
  • General
    Medium temperature range°C0 ... 30
    Temperature safety°C0 ... 90
    Ambient storage temperature°C0 ... 55
    Nominal pressurePNbar16
    Display range0.05 l ... 99,999 m³
    Pulse value*l/pulse0.25, 0.5, 1, 2.5, 10, 100, 1000
    Protection classIP 65
    * Reed switch with luster terminal available.
  • Technical Data
    Nominal diameterDNmm2025252540
    Nominal flow rateQnm³/h2.52.56610
    Overall length (DIN ISO 4064)Lmm190175175260300
    Maximum flow rate (short-term)Qmaxm³/h55121220
    Transition flow rateQtl/h2502506006001000
    Minimum flow rateQminl/h100100240240400
    Starting flow ratel/h20-2520-2540-5040-5060-70
    Flow rate at 1 bar pressure lossm³/h77121224
  • Dimensions
    Nominal diameterDNmm2025252540
    Nominal flow rateQnm³/h2.52.56610
    Overall length (DIN ISO 4064)Lmm190175175260300
    Overall length with couplingL2mm288275275378438
    Connection thread on meter (ISO 228/1)InchG1BG1¼BG1¼BG1¼BG2B
    Connection thread of coupling (DIN 2999)InchR1R1R1R1½
    HeightHmm3545454550
    HeightH1mm120125125125140
    DiameterØ Bmm96102102102137
    Weight without couplingkg1.72.52.52.54.7
    Weight with couplingkg2.13.13.13.15.9
  • Pressure loss graph / Typical error graph

  • General
    Medium temperature range°C0 ... 30
    Temperature safety°C0 ... 90
    Ambient storage temperature°C0 ... 55
    Nominal pressurePNbar16
    Display range0.05 l ... 99,999 m³
    Pulse value*l/pulse0.25, 0.5, 1, 2.5, 10, 100, 1000
    Protection classIP 65
    * Reed switch with luster terminal available.
  • Technical Data
    Nominal diameterDNmm202540
    Nominal flow rateQnm³/h2.5610
    Overall length (DIN ISO 4064)Lmm105150200
    Maximum flow rate (short-term)Qmaxm³/h51220
    Transition flow rateQtl/h2506001000
    Minimum flow rateQminl/h100240400
    Starting flow ratel/h20-2540-5060-70
    Flow rate at 1 bar pressure lossm³/h61222
  • Dimensions
    Nominal diameterDNmm202540
    Nominal flow rateQnm³/h2.5610
    Overall length (DIN ISO 4064)Lmm105150200
    Overall length with couplingL2mm203268338
    Connection thread on meter (ISO 228/1)InchG1BG1¼BG2B
    Connection thread of coupling (DIN 2999)InchR1R1½
    HeightHmm153222
    HeightH1mm154165177
    DiameterØ Bmm96102136
    WidthAmm8295120
    Weight without couplingkg2.13.15.5
    Weight with couplingkg2.53.76.7
  • Pressure loss graph / Typical error graph