SHARKY FS 473

ULTRASONIC FLOW SENSOR

Application

The ultrasonic flow sensor can be used for flow measuring in local and district heating / cooling systems.

Features

  • Dynamic range (DR) of up to 1:250 (qi:qp) in class 2 (depends on meter size), standard 1:100
  • Extreme low power consumption --> longer battery lifetime
  • Approved according EN 1434 and MID in class 2 and 3 (DN 125 only available in class 3) and PTB K 7.2 (cooling)
  • High long term stability
  • Applicable for different calculators with impulse input
  • Continuous time-correct pulses - no pulse packages
  • Free selectable impulse values
  • The temperature range depending on the application up to 5 ... 150 °C
  • Battery or external power supply
  • Specific housing for falling and rising pipes
  • General
    ApplicationHeating - cooling
    ApprovalMID (DE-07-MI004-PTB022) and PTB K 7.2 for cooling (DE-19-M-PTB-0014)
    Ambient classEN 1434 class C / MID class E2 + M2
    Ambient temperature°C5 ... 55 (<35 °C have a positive lifetime effect)
    Battery supply3.0 VDC battery - up to 12 years lifetime
    External supply3.0 ... 5.5 VDC
    Mounting positionAny position
    Protection classHeating: IP 54; heating potted: IP 65; cooling: IP 65
    InterfacesOpen Collector pulse output1 - output for testing and communication2
    Volume pulse value310 ml ... 5000 l/pulse (depending on sensor sizes and supply)
    Cable length of impulse cable2.4 m (4.9 or 9.9 m optional)
    Material of the flow sensor bodyBrass (qp 0.6 ... 100 m³/h), spheroidal cast iron (qp 15 ... 100 m³/h)
    1 The pulse output can be choosen without galvanic isolation (standard) or with galvanic isolation (only with battery supply). The flow sensor has by default a 4-wire impulse cable.
    2 The flow sensor can either emit a high resolution test pulse (standard) or communicate via the same output. By using an adapter the flow sensor can be read via the HYDRO-SET software.
    3 The pulse duration is between 1 and 250 ms. It depends on the pulse value and on the nominal flow rate qp.
    Standard pulse values: 1, 2.5, 10, 25, 100, 250 l/pulse
  • Temperature range
    Temperature range heating - battery supplied°C5 ... 90 / 5 ... 1051
    Temperature range heating - external supplied°C5 ... 105 / 130 / 150 (depends on meter size and material)
    Temperature range cooling - battery supplied / external supplied°C5 ... 50 / 5 ... 90
    1 Only in rising or falling pipes or tilted horizontal installation
  • Technical data
    Nominal flow rateqpm3/h0.61.51.52.5666101515252540406060100100100
    Nominal diameterDNmm15 15 20 20 25 3240 4050 5065 658080100100100100125
    Overall lengthLmm 110 110 130 130 260 260150 300200 270200 300225300250360250360250
    Starting flow ratel/h12.52.5410101020404050508080120120120120120
    Minimum flow rate (DR 1:250)qil/h 6 6 6 1024 24-401601601100110011601160124012401400140014001
    Minimum flow rate (DR 1:100)qil/h6151525606060100150150250250400400600/12002600/120021000/120021000/120021000/12002
    Minimum flow rate (up side down installation)qil/h66610242410015015025025040040012001200120012001200
    Maximum flow rateqsm³/h 1.2 3 3 5 12 121220303050508080120120120120120
    Overload flow ratem³/h 2.5 4.6 4.6 6.7 18.4 18.418.4 2436 3660 609090132132132132132
    Pressure loss at qpΔpmbar95130115110190190190140165165757580807575210210210
    Temp. range heating - brass body°C5 ... 1305 ... 1305 ... 1305 ... 1305 ... 1505 ... 1505 ... 1505 ... 150-5 ... 150-5 ... 150-5 ... 150-5 ... 150-5 ... 150-
    Temp. range heating - spheroidal cast iron body / brass PN 40°C--------5 ... 1055 ... 1055 ... 1055 ... 1055 ... 1055 ... 1055 ... 1055 ... 1055 ... 1055 ... 1055 ... 105
    kv valuem³/h1.954.164.427.5413.7613.7613.7626.7336.9336.9391.2991.29141.42141.42219.09219.09218.22218.22218.22
    1 Valid for horizontal installation only
    2 Up side down installation
  • Dimensions thread version
    Nominal flow rateqpm3/h0.61.51.52.5666101515252540406060100100100
    Nominal diameterDNmm15 15 20 20 25 3240 4050 5065 658080100100100100125
    Overall lengthLmm 110 110 130 130 260 260150 300200 270200 300225300250360250360250
    Overall length with couplingL2mm190190230230380380-440-----------
    HeightHmm 14.514.5181823233333-----------
    HeightH1mm 54.554.556.556.561616166.5-----------
    Length of electronicL1mm 9090909090909090-----------
    Width of electronicBmm65.565.565.565.565.565.565.565.5-----------
    Connection thread on meterInchG¾BG¾BG1BG1BG1¼BG1½ BG2BG2B-----------
    Connection thread of couplingInchR1R1¼R1½R1½-----------
    Operating pressurePNbar16/2516/2516/2516/2516/2516/2516/2516/25-----------
    Weightkg0.60.60.610.611.351.351.522.6-----------
  • Dimensions flange version
    Nominal flow rateqpm3/h0.61.51.52.5666101515252540406060100100100
    Nominal diameterDNmm15 15 20 20 25 3240 4050 5065 658080100100100100125
    Overall lengthLmm 110 110 130 130 260 260150 300200 270200 300225300250360250360250
    HeightHmm----5062.5-6973.573.5858592.592.5108108108108128
    HeightH1mm----6161-66.571.571.5797986.586.596.596.596.596.596.5
    Length of electronicL1mm----9090-909090909090909090909090
    Width of electronicBmm----65.565.5-65.565.565.565.565.565.565.565.565.565.565.565.5
    Flange dimensionFmm----100125-138147147170170185185216216216216255
    Flange diameterDmm----114139-148163163184184200200235235235235270
    Hole circle diameterKmm----85100-1101251251451451601601801 / 1901801 / 1901801 / 1901801 / 1902101 / 220
    Screwhole diameterD1mm----1418-18191919191919191 / 22191 / 22191 / 22191 / 22191 / 26
    Operating pressurePNbar----16/25/40316/25/403-16/25/40316/2516/25/40316/2516/2516/2516/25/40316/2516/2516/2516/2516/25
    Number of screwholespcs----44-444888888888
    Weight brass body2kg----3.354.65-6.6-7.45-9.45-11.1-16.9-16.9-
    Weight spheroidal cast iron body2kg--------5.276.316.598.088.410.011315.761315.7516.95
    1 Values for PN 16 housing
    2 Meter with battery and 2.4 m cable length of the pulse cable
    3 Only up to 105 °C
  • Pressure loss graph / typical error graph

  • Reach

    Information pursuant to Article 33 (1) of Regulation (EC) No 1907/2006 of the European Parliament and of the Council of 18 December 2006:
    This product series contains components with the following substances in a concentration of more than 0.1% weight by weight (w/w):
    - Lead (CAS no.: 7439-92-1)
    - Lead titanium zirconium oxide (CAS no.: 12626-81-2)
    - 1,2-dimethoxyethane (CAS no.: 110-71-4)