HYDRUS 2.0 BULK
ULTRASONIC METER
Application
HYDRUS 2.0 BULK is a static ultrasonic bulk water meter designed for applications of cold and hot water supply enabling accurate measuring with long-term stability under difficult conditions (no measurement of air and insensitive to sedimentation). Developed within the framework of the MID, it complies with the European regulations and holds sanitary conformity certificates (KTW/W270, ACS, WRAS and others). The integrated communication function supports meter data provision via mobile reading (walk-by/drive-by/passive drive-by) or fixed network (upgrade without on-site configuration). In combination with Diehl Metering’s IZAR fixed network system, which stands out with extra high coverage and strong performance to reach hard-to-read locations, high data granularity and timeliness will be maintained. This is what makes it a high responsive infrastructure to take actions immediately.
Features
- DN 50 to 200
- MID approved with dynamic range up to R 1000
- IP 68 suitable for outdoor installations
- Integrated radio communication based on Open Metering telegram (OMS Generation 3 or 4, Profile B)
- Wired M-Bus/Pulse/Pulse, wireless M-Bus, wireless M-Bus in combination with wired L-Bus/Pulse interface
- Display with error and alarm codes including leakage detection and self-monitoring function
- Battery lifetime up to 16 years
- U0 / D0, no need for calming sections
-
Privacy
The HYDRUS 2.0 BULK saves daily 512 consumption values. This data can be read locally and accessed only by using the IZAR@MOBILE 2. As a second logging, a small amount of 32 monthly consumption values can be stored. The HYDRUS 2.0 BULK has a minimal sending interval of about 14 seconds and uses the OMS Generation 3 or 4, Profile B security level. Both, the radio protocol and the optical interface are encrypted by default.
-
Technical data
Medium temperature range °C +0.1 ... +50 (T30 / T50), +0.1 ... +90 (T90) Accuracy Accuracy class 2 acc. to ISO 4064:2014 / OIML R49:2013 Ambient operating temperature °C -10 ... +55 Ambient storage temperature °C -10 ... +70 (>35 °C max. 4 weeks) Environmental class O (Outdoors) Mechanical environmental class M2 Electromagnetic environmental class E2 Flow profile sensitivity class U0/D0 (no calming sections required) Installation position Horizontal, inclined 45°, inclined 90°, vertical Maximum admissible pressure MAP bar 16 Minimum operating pressure bar 0.3 Pressure loss class Δp bar 0.16 Power supply 3.6 V lithium battery (D-cell) Battery lifetime1 Up to 16 years (all communication interfaces) Communication interfaces Optical, OMS wireless M-Bus 434 or 868 MHz, M-Bus, L-Bus and Pulse Data storage For errors, alarms and measuring values, data logging capabilities to record up to 512 daily +32 monthly values Protection class IP 68 1 Depends on the sending interval of the radio telegram, the telegram length and the ambient temperature at the installation -
Technical data display
Display indication LCD, 9-digit, additional symbols/display counter/unit Units displayed DN 50 - 100 Volume (m³ + 2 decimal places) and flow rate (m³/h + 3 decimal places) Units displayed DN 125 - 200 Volume (m³ + 1 decimal place) and flow rate (m³/h + 3 decimal places) Values displayed Display test - volume - battery lifetime - firmware version - software checksum - flow - current/continuous/historical error - alarm status - high resolution volume - due date - due date volume - reverse volume - display counter - low battery indication - leakage indication - metrological log access - radio signal ON/OFF - alarm indication - meter lock ON/OFF -
Interfaces - Overview
Optical For switching the display loop Radio 434 or 868 MHz, Open Metering Standard radio frame (R3) for mobile reading sent every 14 seconds, long range radio frame (R4) for fixed network sent every 5 minutes, extra long range radio frame (R4+) for fixed network sent every 15 minutes M-Bus 2400 baud, cable length 1.5 m, power supply only via built-in battery - is combined with two Pulse outputs L-Bus In combination with radio, cable length 1.5 m (only one interface communicating at the same time) Pulse (Open drain) Two Pulse outputs, or one Pulse and one L-Bus output, Pulse cable length 1.5 m -
Security
Versions OMS Generation 3 or OMS Generation 4, Profile B, selectable -
Volume / Pulse open drain
Max. input voltage V 30 Max. input current mA 27 Max. voltage drop at active output V/mA 2/27 Max. current through inactive output μA/V 5/30 Max. reverse voltage without destroying outputs V 6 (in case current does not exceed 27 mA) Pulse rates DN 50 l/pulse 1 / 10 / 100 / 1000 Pulse rates DN 65 - 150 l/pulse 10 / 100 / 1000 Pulse rates DN 200 l/pulse 100 / 1000 Pulse output 1 variants Total volume or forward volume Pulse output 2 variants Flow direction or error, reverse volume Pulse frequency Max. frequency 10 Hz Pulse width 50 ms -
Possible communication interfaces
Wireless M-Bus/Pulse/L-Bus 3 wire Wireless M-Bus only without wire M-Bus/Pulse/Pulse 5 wire IZAR BE PULSE 4 wire
-
Performance Data - Cold water (T30 / T50) Horizontal
Nominal diameter DN mm 50 65 80 100 125 150 200 Permanent flow rate Q3 m³/h 25 40 63 100 160 250 400 Dynamic (Q3/Q1) R 800 800 800 800 800 800 800 Overload flow rate Q4 m³/h 31.25 50 78.75 125 200 312.50 500 Transitional flow rate Q2 l/h 50 80 126 200 320 500 800 Minimum flow rate Q1 l/h 31.25 50 78.75 125 200 312.50 500 Starting flow rate l/h 15 27 35 45 70 140 200 Pressure loss at Q3 bar 0.16 0.15 0.16 0.13 0.15 0.11 0.12 Pressure loss at Q4 bar 0.25 0.23 0.25 0.2 0.23 0.18 0.19 Maximum flow rate 2 Qhigh m³/h 54 87 134 250 400 625 1000 Flow coefficient Kv m³/h 63 105 158 280 420 747 1140 2 Outlet pressure minimum 3 bar, maximum 100 hours per year, closed pipeline network -
Performance Data - Hot water (T90) Horizontal
Nominal diameter DN mm 50 65 80 100 125 150 200 Permanent flow rate Q3 m³/h 25 40 63 100 - - - Dynamic (Q3/Q1) R 400 400 400 400 - - - Overload flow rate Q4 m³/h 31.25 50 78.75 125 - - - Transitional flow rate Q2 l/h 100 160 250 400 - - - Minimum flow rate Q1 l/h 63 100 160 250 - - - Starting flow rate l/h 15 27 35 45 - - - Pressure loss at Q3 bar 0.16 0.15 0.16 0.13 - - - Pressure loss at Q4 bar 0.25 0.23 0.25 0.2 - - - Flow coefficient Kv m³/h 63 105 158 280 - - - -
Approval
Approval MID DE-19-MI001-PTB011 Dynamic range (Q3/Q1) R Up to 1000 Standards ISO 4064, EN 14154, OIML R49 Sanitary conformity KTW/W270, ACS, WRAS -
Dynamic Range
Q3 25 ... 400 m³/h - T30 R 800 Q3 25 ... 400 m³/h - T50 R 800H / 250V Q3 25 ... 100 m³/h - T90 R 400H / 160V -
Pressure loss graph / Typical error graph
-
Dimensions
Nominal diameter DN mm 50 65 80 100 125 150 200 Overall length (T30 / T50) L mm 200/ 270 / 3003 200 / 3003 200 / 225 / 300 / 3503 250 / 3504 / 360 250 300 / 500 350 Overall length (T90) L mm 200 200 200 / 225 250 - - - Flange diameter 5 D mm 165 185 200 220 250 285 340 Hole circle diameter 5 K mm 125 145 160 180 210 240 295 Number of screwholes 5 pcs 4 4 8 8 8 8 126 Screwhole diameter 5 D1 mm 19 19 19 19 19 23 23 Height H mm 74 87 95 105 120 135 161 Height H1 mm 121 143 147 165 177 185 215 Height H2 mm 61 61 61 61 61 61 61 Counter length L1 mm 98 98 98 98 98 98 98 Meter width B mm 165 185 200 220 250 285 340 Counter width B1 mm 139 139 139 139 139 139 139 Overall weight (approx.) kg 7 / 9 / 9 8 / 11 11 / 13 / 14 / 15 17 / 19 / 20 23 38 / 45 51 3 Optionally with rotatable flange
4 Rotatable flange
5 Flanges according to EN 1092, PN 10/16
6 8 Screwholes for PN 10 -
Meter body variants
a) The cold water meters come with an epoxy-coated cast iron housing as standard. ISO short length variants can optionally be manufactured with a stainless steel housing.
b) ISO long length meters with diameters up to DN 100 can optionally come with rotatable flanges.
c) Hot water meters are always provided with stainless steel housings (EN 1.4408, AISI 316). -
Reach
Information pursuant to Article 33 (1) of Regulation (EC) No 1907/2006 of the European Parliament and of the Council of 18 December 2006:
This product series contains components with the following substances in a concentration of more than 0.1% weight by weight
(w/w):
- Lead titanium zirconium oxide (CAS no.: 12626-81-2)