WESAN WPV A G
BULK WATER METER | WOLTMAN
Application
Meter for measuring heavily fluctuating flow rates.
Features
- Ideal design of housing and housing cover prevents sedimentation, stagnant water and air pockets
- No measuring errors in the switch-over range
- Encapsulated counter of glass/copper IP 68
- Good long-term measuring accuracy
- Complete head unit with counter and sensors can be rotated by 350° for easier reading
- System compatibility, WESAN WPV A G can be extended with IZAR RADIO (clip on radio module), IZAR PULSE (clip on pulse module) or IZAR M-BUS I (clip on M-Bus module)
- In order to secure a safe switch-over the WESAN WPV A G needs a minimum ingoing pressure of 0.6 bar
-
General
Medium temperature range °C 1 ... 30 Temperature safety °C 1 ... 50 Ambient operating temperature °C 1 ... 55 Ambient storage temperature °C 1 ... 55 Nominal pressure PN bar 161 Display range 0.5 l ... 999,999 m³ Protection class IP 68 Available bypass meter ALTAIR V4 1 versions with different nominal pressure on request (see also special versions) -
Technical Data
Nominal diameter DN mm 150 Permament flow rate Q3 m³/h 160 Minimum flow rate Q1 l/h 40 Transitional flow rate Q2 l/h 64 Overload flow rate Q4 m³/h 200 Starting flow rate l/h 5 Permanent flow rate bypass meter Q3 m³/h 16 Switch-over flow rate rising l/h 4350 Switch-over flow rate falling l/h 7800 -
Approval
Nominal diameter DN mm 150 MID (DE-17-MI001-PTB003) • Dynamic range bypass meter ALTAIR V3 (Q3/Q1) R 4000 H Potable water KTW / W270 -
REACH
Information pursuant to Article 33 (1) of Regulation (EC) No 1907/2006 of the European Parliament and of the Council of 18 December 2006:
This product series contains articles with the following substances in a concentration of more than 0.1% weight by weight (w/w):
- Lead (CAS no.: 7439-92-1) -
Special Versions
- Versions with different nominal pressure on request
- Special flange holes on request -
Dimensions
Nominal diameter DN mm 150 Overall length (DIN 19625) L mm 500 ± 15 Flange diameter D mm 285 Hole circle diameter K mm 240 Number of screwholes pcs 8 Screwhole diameter D1 mm 22 Height H mm 150 Height H1 mm 210 Height to remove measuring insert mm 475 Width B1 mm 143 Width B2 mm 310 Diameter Ø B mm 115 Weight of complete meter kg 68 -
Pressure loss graph / Typical error graph