CORONA DP 405
MULTI-JET METER | DRY RUNNER
Application
Contact water meter for proportional control of pumps, motors, etc. and for remote transmission of flow rates.
Features
- Multi-jet impeller meter in completely dry-running design with magnetic coupling
- Only the impeller operates in the wet chamber to prevent faults due to sediment
- Counter can be rotated to any position for easy reading
- Built-in pulse contact (with cable 2 m) cast in a waterproof enclosure and easily replaceable
- Max. contact load 24 V (SELV) 0.2 A
- The outlet is prepared for installing a non-return valve (DVGW approved)
- Special version hard nickel-plated available
-
General
Medium temperature range °C 1 ... 30 Temperature safety °C 1 ... 90 Ambient storage temperature °C 1 ... 55 Nominal pressure PN bar 16 Display range 0.05 l ... 99,999 m³ Pulse value l/pulse 0.251, 0.51, 1, 2.5, 10, 1002, 10002 Pulse transmitter Reed switch sealed (opener) Max. contact load V 24 (without contact protection device) Max. contact load A 0.2 (without contact protection device) Protection class IP 65 1 not available for DN 40
2 with MID approval only 100 or 1000 l/pulse -
Technical Data
Nominal diameter DN mm 20 253 253 25 40 Permanent flow rate Q3 m³/h 4 4 6.3 6.3 16 Overall length (DIN ISO 4064) L mm 190 175 175 260 300 Overload flow rate Q4 m³/h 5 5 7.88 7.88 20 Transitional flow rate Q2 l/h 160 160 253 253 640 Minimum flow rate Q1 l/h 100 100 158 158 400 Starting flow rate l/h 20-25 20-25 40-50 40-50 60-70 Flow rate at 1 bar pressure loss m³/h 7 7 12 12 24 3 only without MID approval -
Approval
MID DE-16-MI001-PTB012 Dynamic range (Q3/Q1) R 40 H Potable water KTW / W270 -
REACH
Information pursuant to Article 33 (1) of Regulation (EC) No 1907/2006 of the European Parliament and of the Council of 18 December 2006:
This product series contains articles with the following substances in a concentration of more than 0.1% weight by weight (w/w):
- Lead (CAS no.: 7439-92-1) -
Dimensions
Nominal diameter DN mm 20 253 253 25 40 Permanent flow rate Q3 m³/h 4 4 6.3 6.3 16 Overall length (DIN ISO 4064) L mm 190 175 175 260 300 Overall length with coupling L2 mm 288 275 275 378 438 Connection thread on meter (ISO 228/1) Inch G1B G1¼B G1¼B G1¼B G2B Connection thread of coupling (DIN 2999) Inch R¾ R1 R1 R1 R1½ Height H mm 35 45 45 45 50 Height H1 mm 120 125 125 125 140 Diameter Ø B mm 96 102 102 102 137 Weight without coupling kg 1.7 2.5 2.5 2.5 4.7 Weight with coupling kg 2.1 3.1 3.1 3.1 5.9 3 only without MID approval -
Pressure loss graph / Typical error graph
-
General
Medium temperature range °C 1 ... 30 Temperature safety °C 1 ... 90 Ambient storage temperature °C 1 ... 55 Nominal pressure PN bar 16 Display range 0.05 l ... 99,999 m³ Pulse value l/pulse 0.251, 0.51, 1, 2.5, 10, 100, 1000 Protection class IP 65 1 not available for DN 40
Note: only without MID approval -
Technical Data
Nominal diameter DN mm 20 25 40 Permanent flow rate Q3 m³/h 4 6.3 16 Overall length (DIN ISO 4064) L mm 105 150 200 Overload flow rate Q4 m³/h 5 7.88 20 Transitional flow rate Q2 l/h 160 253 640 Minimum flow rate Q1 l/h 100 158 400 Starting flow rate l/h 20-25 40-50 60-70 Flow rate at 1 bar pressure loss m³/h 6 12 22 -
Approval
MID - Dynamic range (Q3/Q1) R 40 H Potable water KTW / W270 -
REACH
Information pursuant to Article 33 (1) of Regulation (EC) No 1907/2006 of the European Parliament and of the Council of 18 December 2006:
This product series contains articles with the following substances in a concentration of more than 0.1% weight by weight (w/w):
- Lead (CAS no.: 7439-92-1) -
Dimensions
Nominal diameter DN mm 20 25 40 Permanent flow rate Q3 m³/h 4 6.3 16 Overall length (DIN ISO 4064) L mm 105 150 200 Overall length with coupling L2 mm 203 268 338 Connection thread on meter (ISO 228/1) Inch G1B G1¼B G2B Connection thread of coupling (DIN 2999) Inch R¾ R1 R1½ Height H mm 15 32 22 Height H1 mm 154 165 177 Diameter Ø B mm 96 102 136 Width A mm 82 95 120 Weight without coupling kg 2.1 3.1 5.5 Weight with coupling kg 2.5 3.7 6.7 -
Pressure loss graph / Typical error graph