HYDRUS 2.0 RESIDENTIAL

HYDRUS 2.0 RESIDENTIAL

ULTRASONIC METER

Application

HYDRUS 2.0 RESIDENTIAL is a static water meter operating on ultrasonic measuring technology. This technology enables accurate calculation of water consumption with long-term stability and eliminates measuring deviations caused by sand, suspended particles, scale or air pockets. Moreover it does not require any earthing. Developed within the framework of the MID, HYDRUS 2.0 RESIDENTIAL complies with the European regulations and holds sanitary conformity certificates (ACS, WRAS, BELGAQUA, DM174 and others). The meter is also designed for cold and hot water.
Its integrated radio enables remote reading of the meter's index and alarms both in mobile (walk-by, drive-by, passive drive-by) and fixed network mode.
HYDRUS 2.0 RESIDENTIAL offers a wide choice of connectivities compatible with the different IZAR reading modes. A complete Diehl Metering solution is thus available to meet your needs.

Features

  • DN 15 to 50
  • MID approval up to R=800
  • IP 68
  • OMS radio, Wired M-Bus/Pulse x2, OMS radio/L-Bus/Pulse, Pulse x2, Remote radio with IZAR BE PULSE
  • Display with symbols and error codes
  • Alarm functions
  • Battery lifetime up to 16 years
  • U0 / D0, no calming section needed
  • Privacy

    The HYDRUS 2.0 RESIDENTIAL saves 512 consumption values with a daily interval. This data can be read locally and accessed only by using the IZAR@MOBILE. As a second logging, a small amount of 32 consumption values can be stored. Both the radio protocol and the optical interface are encrypted by default.

  • Reach

    Information pursuant to Article 33 (1) of Regulation (EC) No 1907/2006 of the European Parliament and of the Council of 18 December 2006:
    This product series contains components with the following substances in a concentration of more than 0.1% weight by weight
    (w/w):
    - Lead (only for the flange variants) - (CAS no.: 7439-92-1)
    - Lead titanium zirconium oxide (CAS no.: 12626-81-2)

  • General
    Medium temperature range°C+0.1 ... +90
    Ambient operating temperature°C-10 ... +55
    Ambient storage temperature°C-10 ... +70 (>35 °C max. 4 weeks)
    Environmental classO (Outdoors)
    Mechanical environmental classM2
    Electromagnetic environmental classE2
    Nominal pressurePNbar16
    Power supply2x 3.6 VDC lithium batteries
    Battery lifetime T301/T501Up to 16 years
    Battery lifetime T701/T901Up to 16 years
    Communication interfacesOptical, OMS 434 or 868 MHz, M-Bus, L-Bus and Pulse
    Data storageFor errors, alarms and measuring values, data logging capabilities to record up to 1024 daily values +32 monthly values and two annual due dates
    Protection classIP 68
    1 Theorical lifetime, depends on the sending interval of the radio telegram, the telegram length and the ambient temperature at the installation.
  • Technical Data Display
    Display indicationLCD, 9-digit, additional symbols/display counter/unit
    Units displayed DN 15 - DN 50Volume (m³ + 3 digits after decimal point) and flow rate (m³/h + 3 digits after decimal point)
    Values displayedDisplay test - volume - battery lifetime - firmware version - software checksum - flow rate - current/continuous/historical error - alarm status - high resolution volume - due date - due date volume - reverse volume - flow direction - display counter - low battery indication - leakage indication - metrological log access - radio signal ON/OFF - alarm indication - billing symbol
  • Communication interfaces
    OpticalFor switching the display menu, reading and configuration with IZAR@MOBILE
    Radio434 or 868 MHz, Open Metering Standard (OMS) radio frame (short frame) for mobile reading sent every 14 seconds, long range radio frame for fixed network sent every 15 minutes
    M-Bus2,400 baud, cable length 1.5 m*, power supply only via built-in battery
    L-BusOnly active when radio is deactivated
    Pulse (Open drain)1 or 2 pulse outputs with cable length 1.5 m*, Pulse output soldered with IZAR BE PULSE cable lenght 1.5m*
    *May vary by up to ± 3.5% due to manufacturing tolerances
  • Security
    VersionsOMS Generation 3 - Profile A or OMS Generation 4 - Profile B
  • Volume / Pulse Open Drain
    Max. input voltageV30
    Max. input currentmA27
    Max. voltage drop at active outputV/mA2 / 27
    Max. current through inactive outputμA/V5 / 30
    Max. reverse voltage without destroying outputsV6 (in case current does not exceed 27 mA)
    Pulse ratesl/pulse1 / 10 (depending on nominal diameter)
    Configuration pulse output 1Total volume or forward volume
    Configuration pulse output 2Flow direction, error, reverse volume or forward volume
    Pulse frequencyMax. frequency 10 Hz
    Pulse width50 - 125 ms
  • Available versions
    OMS radio + Pulse / L-Bus + Pulse3 wires - radio and forward volume on pulse output / 3 wires - L-Bus and forward volume on pulse output
    Wired M-Bus + Pulses x25 wires - forward volume on pulse output 1 and reverse volume on pulse output 2
    Pulses x24 wires - total volume on pulse output 1 and direction on pulse output 2 with fraud
    Remote radio with IZAR BE PULSEWith IZAR BE PULSE completly soldered to HYDRUS 2 to put a radio clip-on module (LoRaWAN, Sigfox, Wize, OMS)
  • Technical Data
    Nominal diameterDNmm1515315152020202020
    Permanent flow rateQ3m3/h2.52.52.52.52.52.5444
    Overall lengthLmm110115165170130190130165190
    Dynamic (Q3/Q1)R800800800800800800800800800
    Overload flow rateQ4m3/h3.1253.1253.1253.1253.1253.125555
    Transitional flow rateQ2l/h555555888
    Minimum flow rateQ1l/h3.133.133.133.133.133.13555
    Starting flow ratel/h1.41.41.41.41.41.42.52.52.5
    Pressure loss at Q3bar0.460.460.460.460.40.40.40.40.4
    Pressure loss at Q4bar0.720.720.720.720.630.630.630.630.63
    Maximum flow rate2Qhighm³/h4.374.374.374.374.374.37777
    Flow rate at ΔP = 1 bar3.693.693.693.693.953.955.395.395.39
    2 Outlet pressure minimum 3 bars, maximum 100 hours per year, closed pipeline network
    3 Please see table DIMENSIONS
    Other on request
  • Approval
    ApprovalMID DE-19-MI001-PTB012 | UK/0126/0326
    Dynamic range (Q3/Q1)RUp to R=800
    StandardsISO 4064 | EN 14154 | OIML R49
    Sanitary conformityACS | WRAS | DM174 | BELGAQUA | KTW / W270
  • Dynamic Range (R=Q3/Q1)
    Q3 2.5 m³/h - T30 / T50R800
    Q3 2.5 m³/h - T70 / T90R800H / 400V
    Q3 4 m³/h - T30R800
    Q3 4 m³/h - T50 / T70 / T90R800H / 400V
    H=horizontal installation position / V=vertical installation position
    Other values on request
  • Dimensions
    Nominal diameterDNmm1515315152020202020
    Permanent flow rateQ3m3/h2.52.52.52.52.52.5444
    Overall lengthLmm110115165170130190130165190
    Counter lengthL1mm898989898989898989
    Counter widthBmm898989898989898989
    Overall length with couplingL2mm190195245250230290230295290
    Connection thread on meterInchG¾BG¾BG¾BG¾BG1BG1BG1BG1BG1B
    Connection thread of couplingInchR1
    HeightH1mm717171717474747474
    Weight without coupling (approx.)kg0.70.70.80.80.80.90.81.00.9
    Weight with coupling (approx.)kg1.11.11.21.21.21.31.21.61.3
    HeightHmm181818182121212721
    3 Further version with connection thread on meter inlet G7/8B and meter outlet G3/4B on request
  • Pressure loss graph / Typical error graph

  • Technical Data
    Nominal diameterDNmm252550505050
    Permanent flow rateQ3m3/h6.31016162525
    Overall lengthLmm260260270300270300
    Dynamic (Q3/Q1)R400800250250400400
    Overload flow rateQ4m3/h7.8712.5202031.2531.25
    Transitional flow rateQ2l/h25.220102102100100
    Minimum flow rateQ1l/h15.812.5646462.562.5
    Starting flow ratel/h5525252525
    Pressure loss at Q3bar0.220.540.10.10.250.25
    Pressure loss at Q4bar0.340.840.190.190.450.45
    Maximum flow rate2Qhighm³/h11.0217.532.1332.1332.1332.13
    Flow rate at ΔP = 1 bar13.4313.4346.046.046.046.0
    2 Outlet pressure minimum 3 bars, maximum 100 hours per year, closed pipeline network
    Other on request
  • Approval
    ApprovalMID DE-19-MI001-PTB012 | UK/0126/0326
    Dynamic range (Q3/Q1)RUp to R=800
    StandardsEN 4064, EN 14154, OIML R49
    Sanitary conformityACS | WRAS | DM174 | BELGAQUA | KTW / W270
  • Dynamic Range (R=Q3/Q1)
    Q3 6.3 m³/h - T30R400
    Q3 6.3 m³/h - T50 / T70 / T90R400H / 250V
    Q3 10 m³/h - T30R800
    Q3 10 m³/h - T50 / T70 / T90R800H / 400V
    Q3 16 m³/h - T30R800
    Q3 16 m³/h - T50 / T70 / T90R800H / 400V
    Q3 16 m³/h - DN 50 - T30 / T50 / T70 / T90R250
    Q3 25 m³/h - DN 50 - T30 / T50 / T70 / T90R400
    H=horizontal installation position / V=vertical installation position
  • Dimensions
    Nominal diameterDNmm252550505050
    Permanent flow rateQ3m3/h6.31016162525
    Overall lengthLmm260260270300270300
    Counter lengthL1mm898992929292
    Counter widthBmm898994949494
    DIMENSIONS - THREAD......
    Overall length with couplingL2mm380380390420390420
    Connection thread on meterInchG1¼BG1¼BG2½BG2½BG2½BG2½B
    Connection thread of couplingInchR1R1R2R2R2R2
    HeightH1mm787890909090
    Weight without coupling (approx.)kg1.41.43.94.053.94.05
    Weight with coupling (approx.)kg2.02.05.55.655.55.65
    HeightHmm272741414141
    DIMENSIONS - FLANGE......
    Flange diameterDmm115115----
    Hole circle diameterKmm8585----
    Number of screwholespcs44----
    Screwhole diameterD1mm1414----
    HeightHmm5050----
    HeightH1mm8484----
    WidthFmm100100----
    Weight with flanges (approx.)kg3.43.4----
  • Pressure loss graph / Typical error graph

You are currently using an outdated Internet browser, which is no longer supported for technical reasons. To use the Diehl website right, please use a modern browser in the latest version, such as Edge, Chrome, Firefox or Safari.

Consent

We would like to use Google Analytics to optimise the design of our website. Through this, Google collects data which is aggregated and made available to us as a statistical overview. By clicking "Agree", you consent to tracking by Google Analytics. This consent is voluntary and can be revoked at any time. If you click "Decline", no tracking will take place. For more information, please see our privacy policy.