RAY MC
Compact Energy Meter | Mechanical
Application
Fully electronic measuring capsule heat meter, heat and cooling meter or cooling meter with impeller scanning for volume measuring and energy calculation. Highly accurate recording of all billing data in a heating circuit or a cooling / heating circuit at medium temperatures from 5 °C up to 90 °C.
Features
- Electronic sensor control for recording flow rate
- Lithium battery, lifetime up to 12 years
- Optical ZVEI interface equipped as standard
- Adjustable reading date for billing
- Rotatable integrator
- Single-line 7-digit display for easy meter reading
- Can be installed in housings from the Diehl Metering range of accessories or in housings with a 2" coupling thread already available in the network
-
Components
Multi-jet volume measuring component (DN 15 - 20) Calculator, contains hardware and software for measuring flow rate, temperature and energy consumptionTemperature sensor permanently connected in integrator
-
Calculator - basic features
Ambient class EN 1434 class C / MID E1 + M1 Protection class DIN 40050 / IEC-EN 60529 IP 54 (heat meter) | IP 65 with potted calculator (combined heat-cooling / cooling meter) Interfaces standard Optical ZVEI according IEC 870-5 Interfaces optional M-Bus, radio, pulse Note: IZAR@SET / HYDRO-SET Software for configuration of meters, reading of measured values and printout of meter logs. Available under www.diehl.com/metering (Products - Downloads) -
Display
Display indication LCD, 7-digit Unit MWh - kWh - GJ - MJ - kW - m³/h - l/h - m³ - l Total values 9,999,999 - 999,999.9 - 99,999.99 - 9,999.999 Values displayed Power - energy - flow rate - temperature - energy on reading date - reading date -
Temperature input
Temperature sensor type Pt 500 / 2-wire Measuring cycle T s 32 Max. temperature difference ΔΘ K +102 Min. temperature difference ΔΘ K +3 Starting temperature difference ΔΘ K +0.25 Absolute temperature measurement range Θ °C 0 ... 105 -
Supply voltage
Operating voltage UN VDC 3.0 (lithium battery) Battery lifetime Up to 12 years Nominal power PN μW 30 -
Interfaces - Overview
Optical ZVEI interface for communication, M-Bus protocol M-Bus According to EN 1434-3. Data reading and parametrization are via two wires with polarity reversal protection. (Meter is powered with energy via M-Bus Master) Radio 868 MHz, Real Data or Open Metering Standard (OMS) protocol Pulse Output for heat meters or cooling meters (energy / volume), for cooling-heat meters (energy cooling / energy heating or energy cooling / total volume), for heat-cooling meters (energy heating / energy cooling or energy heating / total volume) -
Radio interface - specification
Frequency MHz 868 Protocol Real Data (according EN 13757) or Open Metering Standard (OMS) Transmission power mW 10 Transmission interval sec. 64 Communication Via Bluetooth optohead and IZAR@SET / HYDRO-SET software or IZAR@MOBILE software -
Volume- / energy pulse
Output type Open collector Max. frequency Hz 4 Max. input voltage V 30 Max. input current mA 100 Max. voltage drop at active output V/mA 2/27 Max. current through inactive output μA/V 5/30 Max. reverse voltage without destroying outputs V 6 Min. pulse duration ms 125 Min. pulse break ms 125
-
General
Temperature range °C 5 ... 90 Ambient operating temperature °C 0 ... 55 Ambient storage temperature °C -20 ... 55 Nominal pressure PN bar 16 Temperature sensor type Pt 500 with 2 wire leads Cable length of temperature sensor 0.4 m mounted in measuring capsule; 1.5 m free Mounting position energy meter In any position, also up side down Approval MID (DE-07-MI004-PTB030) and PTB TR K7.2 (DE-19-M-PTB-0001) for cooling meter -
Temperature sensor
Tangential sensor1 - - - Type 1 0.4 m | Ø 5.2 mm | PU grey | 3 K - 102 K Free sensor - - - Type 1 1.5 m | Ø 5.2 mm | PU grey | 3 K - 102 K Type 2 1.5 m | Ø 5 mm | PU grey | 3 K - 102 K 1 mounted in measuring capsule -
Technical data
Nominal diameter DN mm 15 15 20 Nominal flow rate qp m³/h 0.6 1.5 2.5 Maximum flow rate qs m³/h 1.2 3 5 Minimum flow rate at ΔΘ 3 K qi l/h 120 120 120 Minimum flow rate1 qi l/h 6 15 25 Starting flow rate l/h 1.5 - 2 3 - 4 5 - 6 Pressure loss at qp Δp mbar 243 243 242 Flow rate at 0.1 bar pressure loss m³/h 0.385 0.962 1.607 Flow resistance coefficient Zeta 56.25 9 10.24 1 according to EN1434 for flow sensor -
Dimensions
Nominal diameter DN mm 15 15 20 Nominal flow rate qp m³/h 0.6 1.5 2.5 Connection interface Ø A Inch G2B G2B G2B Height H mm 15.2 15.2 15.2 Height H1 mm 55 55 55 Diameter Ø B mm 63 63 63 Diameter Ø C mm 74 74 74 Weight kg 0.5 0.5 0.5 -
Dimensions - accessory
Nominal diameter DN mm 15 15 20 Nominal flow rate qp m³/h 0.6 1.5 2.5 Overall length L mm 110 110 130 Overall length with coupling L2 mm 190 190 210 Height H mm 17 17 21 Height H1 mm 29 29 31 Order no. 1 piece 3031602 3031602 3031600 Order no. 6 pieces 3026961 3026961 3029251 -
Pressure loss graph / Typical error graph