HYDRUS 2.0 BULK
HYDRUS 2.0 BULK
HYDRUS 2.0 BULK is a static ultrasonic bulk water meter designed for all applications of cold water supply enabling accurate measuring with long-term stability under difficult conditions (no measurement of air and insensitive to sedimentation). Developed within the framework of the MID, it complies with the European regulations and holds sanitary conformity certificates (KTW/W270, ACS, WRAS and others). The integrated communication function supports meter data provision via mobile reading (walk-by/drive-by/passive drive-by) or fixed network (upgrade without on-site configuration). In combination with Diehl Metering’s IZAR fixed network system, which stands out with extra high coverage and strong performance to reach hard-to-read locations, high data granularity and timeliness will be maintained. This is what makes it a high responsive infrastructure to take actions immediately.
The HYDRUS 2.0 BULK saves daily 512 consumption values. This data can be read locally and accessed only by using the IZAR@MOBILE 2. As a second logging, a small amount of 32 monthly consumption values can be stored. The HYDRUS 2.0 BULK has a minimal sending interval of about 14 seconds and uses the OMS Generation 3 or 4, Profile B security level. The device uses five keys for the protection of values which are sent out by radio.
- DN 50 to 125
- MID approved with dynamic range up to R 1000
- IP 68 suitable for outdoor installations
- Integrated radio communication based on Open Metering telegram (OMS Generation 3 or 4, Profile B)
- Wired M-Bus/Pulse/Pulse, wireless M-Bus, wireless M-Bus/L-Bus/Pulse interface
- Display with error and alarm codes including leakage detection and self-monitoring function
- Battery lifetime up to 12 years
-
General
Medium temperature range °C 0.1 ... 50 Ambient operating temperature °C 1 ... 70 Ambient storage temperature °C -10 ... +70 (>35 °C max. 4 weeks) Nominal pressure PN bar 16 Power supply 3.6 V lithium battery (D-cell) Battery lifetime T501 Up to 12 years (all communication interfaces) Communication interfaces Optical, OMS wireless M-Bus 434 or 868 MHz, M-Bus, L-Bus and Pulse Data storage For errors, alarms and measuring values, data logging capabilities to record up to 512 daily +32 monthly values Protection class IP 68 1 Depends on the sending interval of the radio telegram, the telegram length and the ambient temperature at the installation -
Technical data display
Display indication LCD, 9-digit, additional symbols/display counter/unit Units displayed DN 50 - DN 100 Volume (m³ + 2 decimal places) and flow rate (m³/h + 3 decimal places) Units displayed DN 125 Volume (m³ + 1 decimal place) and flow rate (m³/h + 3 decimal places) Values displayed Display test - volume - battery lifetime - firmware version - software checksum - flow - current/continuous/historical error - alarm status - high resolution volume - due date - due date volume - reverse volume - display counter - low battery indication - leakage indication - metrological log access - radio signal ON/OFF - alarm indication - meter lock ON/OFF -
Interfaces - Overview
Optical For configuration and switching the display loop Radio 434 or 868 MHz, Open Metering Standard radio frame (R3) for mobile reading sent every 142/643 seconds, long range radio frame (R4) for fixed network sent every 152/53 minutes, extra long range radio frame (R4+) for fixed network sent every 602/153 minutes M-Bus 2400 baud, cable length 1.5 m, power supply only via built-in battery - is combined with two Pulse outputs L-Bus In combination with radio, cable length 1.5 m (only one interface communicating at the same time) Pulse (Open drain) Two Pulse outputs, or one Pulse and one L-Bus output, Pulse cable length 1.5 m 2 Fixed Network ready
3 Fixed Network -
Security
Versions OMS Generation 3 or OMS Generation 4, Profile B, selectable -
Volume / Pulse open drain
Max. input voltage V 30 Max. input current mA 27 Max. voltage drop at active output V/mA 2/27 Max. current through inactive output μA/V 5/30 Max. reverse voltage without destroying outputs V 6 (in case current does not exceed 27 mA) Pulse rates (DN 50 - 125) l/pulse 1 / 10 / 100 / 1000 Pulse output 1 variants Total volume or forward volume Pulse output 2 variants Total volume or forward volume, reverse volume Pulse frequency Max. frequency 10 Hz -
Possible communication interfaces
Wireless M-Bus/Pulse/L-Bus 3 wire Wireless M-Bus only without wire M-Bus/Pulse/Pulse 5 wire IZAR PULSE BE 4 wire
-
Technical Data
Nominal diameter DN mm 50 65 80 100 125 Permanent flow rate Q3 m3/h 25 40 63 100 160 R standard 800 800 800 800 800 Overload flow rate Q4 m3/h 31.25 50 78.75 125 200 Transitional flow rate Q2 l/h 50 80 126 200 320 Minimum flow rate Q1 l/h 31.25 50 78.75 125 200 Starting flow rate l/h 15 27 35 45 70 Pressure loss at Q3 bar 0.16 0.16 0.16 0.16 0.16 Pressure loss at Q4 bar 0.25 0.25 0.25 0.25 0.25 Maximum flow rate4 Qhigh m³/h 50 78.75 120 195 315 Kv (ΔP=Q²/Kv²) 63 103 158 267 413 4 Based on pressure in distribution network and temperature (3 bar / 20 °C) -
Approval
Approval MID DE-19-MI001-PTB011 Dynamic range (Q3/Q1) R Up to 1000 Standards ISO 4064, EN 14154, OIML R49 Sanitary conformity KTW/W270, ACS, WRAS -
Dimensions
Nominal diameter DN mm 50 65 80 100 125 Permanent flow rate Q3 m3/h 25 40 63 100 160 Overall length L mm 2005/ 270 / 3006 2005 / 3006 200 / 2255 / 300 / 3506 2505 / 3506 / 360 2505 Flange diameter D mm 165 185 200 220 250 Hole circle diameter K mm 125 145 160 180 210 Number of screwholes pcs 4 4 8 8 8 Screwhole diameter D1 mm 19 19 19 19 19 Height H mm 74 87 95 105 120 Height H1 mm 121 143 147 165 177 Height H2 mm 61 61 61 61 61 Counter length L1 mm 139 139 139 139 139 Meter width B mm 165 185 200 220 250 Counter width B1 mm 98 98 98 98 98 Overall weight (approx.) kg 7 / 9 / 9 8 / 11 11 / 13 / 14 / 15 17 / 19 / 20 23 5 ISO length
6 Rotatable flange - Pressure loss graph / Typical error graph