CORONA 101/102
MULTI-JET METER | WET RUNNER
Domestic water meter
- Extremely low pressure loss and considerably extended measuring range
- Records very small amounts of water consumption
- Maximum long-term accuracy and absolutely corrosion-resistant
- Measuring data better than specified by calibration regulations
- Strainer insert in inlet connection for cleaning without damaging the seal
- Capable of withstanding any load for a short time
- Forward and return metering
- Fine adjustment by regulating plug
-
General
Medium temperature range °C 1 ... 30 Temperature safety °C 1 ... 50 Ambient operating temperature °C 1 ... 55 Ambient storage temperature °C 1 ... 55 Nominal pressure PN bar 16 Display range 0.05 l ... 999,999 m³ Protection class IP 68 -
Technical data
Nominal diameter DN mm 201 252 402 Permanent flow rate Q3 m³/h 4 10 16 Overload flow rate Q4 m³/h 5 12.5 20 Transitional flow rate Q2 l/h 40 160 256 Minimum flow rate Q1 l/h 25 100 160 Starting flow rate l/h 4-6 6-8 20-25 Pressure loss at Q3 bar 0.6 0.6 0.6 1 at dynamic range R 160
2 at dynamic range R 100 -
Approval
Nominal diameter DN mm 201 252 402 Permanent flow rate Q3 m³/h 4 10 16 MID TH 8628 TH 8628 TH 8628 Dynamic range horizontal installation (Q3/Q1) R 40 / 80 / 160 50 / 80 / 100 50 / 80 / 100 -
Dimensions
Nominal diameter DN mm 201 252 402 Permanent flow rate Q3 m³/h 4 10 16 Overall length (DIN ISO 4064) L mm 190 260 300 Overall length with coupling L2 mm 288 378 438 Connection thread on meter (ISO 228/1) Inch G1B G1¼B G2B Connection thread of coupling (DIN 2999) Inch R¾ R1 R1½ Height H mm 41 44 46 Height H1 mm 79 86 104 Diameter Ø B mm 98 104 137 Width A mm Weight without coupling kg 1.8 2.8 5.4 - Pressure loss graph / Typical error graph
-
General
Medium temperature range °C 1 ... 30 Temperature safety °C 1 ... 50 Ambient operating temperature °C 1 ... 55 Ambient storage temperature °C 1 ... 55 Nominal pressure PN bar 16 Display range 0.05 l ... 999,999 m³ Protection class IP 68 -
Technical data
Nominal diameter DN mm 20 25 40 Permanent flow rate Q3 m³/h 4 10 16 Overload flow rate Q4 m³/h 5 12.5 20 Transitional flow rate Q2 l/h 40 160 256 Minimum flow rate Q1 l/h 25 100 160 Starting flow rate l/h 4-6 6-8 20-25 Pressure loss at Q3 bar 0.6 0.6 0.6 -
Approval
Nominal diameter DN mm 20 25 40 Permanent flow rate Q3 m³/h 4 10 16 MID TH 8628 TH 8628 TH 8628 Dynamic range horizontal installation (Q3/Q1) R 40 / 80 / 160 80 80 -
Dimensions
Nominal diameter DN mm 20 25 40 Permanent flow rate Q3 m³/h 4 10 16 Overall length (DIN ISO 4064) L mm 105 150 (135)* 200 (150)* Overall length with coupling L2 mm 203 268 (253) 338 (288) Connection thread on meter (ISO 228/1) Inch G1B G1¼B G2B Connection thread of coupling (DIN 2999) Inch R¾ R1 R1½ Height H mm 18 31 21 Height H1 mm 118 130 147 Diameter Ø B mm 98 101 136 Width A mm 82 95 120 Weight without coupling kg 1.9 3.2 6.3 1 Special overall length on request - Pressure loss graph / Typical error graph