ALTAIR V4 CONCENTRIC
ROTARY PISTON METER
ALTAIR V4 CONCENTRIC is the latest generation of volumetric water meters specifically designed for installation on coaxial base in concentric manifold.
ALTAIR V4 CONCENTRIC adapts to the most demanding environments and varying water qualities while maintaining its excellent metrology.
Developed within the MID framework, it complies with European standards and holds certificates of sanitary conformity.
Modular, ALTAIR V4 CONCENTRIC may be fitted at any time with an IZAR clip-on module converting it into a communicating meter, ready for mobile reading (walk-by, drive-by, passive drive-by) or fixed network reading (radio/wired).
- Q3=2.5 m3/h / Q3=4 m3/h
- MID approval up to R=630
- Starting flow rate at 0.4 l/h (Q3=2.5m3/h) / 0.7 l/h (Q3=4m3/h)
- Composite or brass body
- Cold water
-
Technical data
Overload flow rate Q3 m³/h 2.5 4 R standard* Q3/Q1 160 160 Starting flow rate l/h 0.4 0.7 Minimum flow rate Q1 l/h 15.62 25 Transition flow rate Q2 l/h 25 40 Maximum flow rate Q4 m³/h 3.125 5 Head loss at Q3 bar 0.59 0.55 Head loss at Q4 bar 0.92 0.85 Kvs (deltaP=Q²/Kvs²) 3.25 5.41 1 other values on request -
Approval
MID Approval LNE-6250 | Type A2 Standards EN 14154 | ISO 4064 | OIML R49 Sanitary conformity ACS | WRAS -
Temperature and pressure
Water temperature °C 0.1 ... +50 Ambient operating temperature °C +1 ... +55 Storage temperature °C -10 ... +55 Nominal pressure PN bar 16 - Dimensions
- Precision curve
-
Option
- Plastic register