HYDRUS 2.0 RESIDENTIAL
ULTRASONIC METER
Application
HYDRUS 2.0 RESIDENTIAL is a static water meter operating on ultrasonic measuring technology. This technology enables accurate calculation of water consumption with long-term stability and eliminates measuring deviations caused by sand, suspended particles, scale or air pockets. Moreover it does not require any earthing. Developed within the framework of the MID, HYDRUS 2.0 RESIDENTIAL complies with the European regulations and holds sanitary conformity certificates (ACS, WRAS, BELGAQUA, DM174 and others). The meter is also designed for cold and hot water.
Its integrated radio enables remote reading of the meter's index and alarms both in mobile (walk-by, drive-by, passive drive-by) and fixed network mode.
HYDRUS 2.0 RESIDENTIAL offers a wide choice of connectivities compatible with the different IZAR reading modes. A complete Diehl Metering solution is thus available to meet your needs.
Features
- DN 15 to 50
- MID approval up to R=800
- IP 68
- OMS radio, Wired M-Bus/Pulse x2, OMS radio/L-Bus/Pulse, Pulse x2, Remote radio with IZAR BE PULSE
- Display with symbols and error codes
- Alarm functions
- Battery lifetime up to 16 years
- U0 / D0, no calming section needed
-
Privacy
The HYDRUS 2.0 RESIDENTIAL saves 512 consumption values with a daily interval. This data can be read locally and accessed only by using the IZAR@MOBILE. As a second logging, a small amount of 32 consumption values can be stored. Both the radio protocol and the optical interface are encrypted by default.
-
Reach
Information pursuant to Article 33 (1) of Regulation (EC) No 1907/2006 of the European Parliament and of the Council of 18 December 2006:
This product series contains components with the following substances in a concentration of more than 0.1% weight by weight
(w/w):
- Lead (only for the flange variants) - (CAS no.: 7439-92-1)
- Lead titanium zirconium oxide (CAS no.: 12626-81-2) -
General
Medium temperature range °C +0.1 ... +90 Ambient operating temperature °C -10 ... +55 Ambient storage temperature °C -10 ... +70 (>35 °C max. 4 weeks) Environmental class O (Outdoors) Mechanical environmental class M2 Electromagnetic environmental class E2 Nominal pressure PN bar 16 Power supply 2x 3.6 VDC lithium batteries Battery lifetime T301/T501 Up to 16 years Battery lifetime T701/T901 Up to 16 years Communication interfaces Optical, OMS 434 or 868 MHz, M-Bus, L-Bus and Pulse Data storage For errors, alarms and measuring values, data logging capabilities to record up to 1024 daily values +32 monthly values and two annual due dates Protection class IP 68 1 Theorical lifetime, depends on the sending interval of the radio telegram, the telegram length and the ambient temperature at the installation. -
Technical Data Display
Display indication LCD, 9-digit, additional symbols/display counter/unit Units displayed DN 15 - DN 50 Volume (m³ + 3 digits after decimal point) and flow rate (m³/h + 3 digits after decimal point) Values displayed Display test - volume - battery lifetime - firmware version - software checksum - flow rate - current/continuous/historical error - alarm status - high resolution volume - due date - due date volume - reverse volume - flow direction - display counter - low battery indication - leakage indication - metrological log access - radio signal ON/OFF - alarm indication - billing symbol -
Communication interfaces
Optical For switching the display menu, reading and configuration with IZAR@MOBILE Radio 434 or 868 MHz, Open Metering Standard (OMS) radio frame (short frame) for mobile reading sent every 14 seconds, long range radio frame for fixed network sent every 15 minutes M-Bus 2,400 baud, cable length 1.5 m*, power supply only via built-in battery L-Bus Only active when radio is deactivated Pulse (Open drain) 1 or 2 pulse outputs with cable length 1.5 m*, Pulse output soldered with IZAR BE PULSE cable lenght 1.5m* *May vary by up to ± 3.5% due to manufacturing tolerances -
Security
Versions OMS Generation 3 - Profile A or OMS Generation 4 - Profile B -
Volume / Pulse Open Drain
Max. input voltage V 30 Max. input current mA 27 Max. voltage drop at active output V/mA 2 / 27 Max. current through inactive output μA/V 5 / 30 Max. reverse voltage without destroying outputs V 6 (in case current does not exceed 27 mA) Pulse rates l/pulse 1 / 10 (depending on nominal diameter) Configuration pulse output 1 Total volume or forward volume Configuration pulse output 2 Flow direction, error, reverse volume or forward volume Pulse frequency Max. frequency 10 Hz Pulse width 50 - 125 ms -
Available versions
OMS radio + Pulse / L-Bus + Pulse 3 wires - radio and forward volume on pulse output / 3 wires - L-Bus and forward volume on pulse output Wired M-Bus + Pulses x2 5 wires - forward volume on pulse output 1 and reverse volume on pulse output 2 Pulses x2 4 wires - total volume on pulse output 1 and direction on pulse output 2 with fraud Remote radio with IZAR BE PULSE With IZAR BE PULSE completly soldered to HYDRUS 2 to put a radio clip-on module (LoRaWAN, Sigfox, Wize, OMS)
-
Technical Data
Nominal diameter DN mm 15 153 15 15 20 20 20 20 20 Permanent flow rate Q3 m3/h 2.5 2.5 2.5 2.5 2.5 2.5 4 4 4 Overall length L mm 110 115 165 170 130 190 130 165 190 Dynamic (Q3/Q1) R 800 800 800 800 800 800 800 800 800 Overload flow rate Q4 m3/h 3.125 3.125 3.125 3.125 3.125 3.125 5 5 5 Transitional flow rate Q2 l/h 5 5 5 5 5 5 8 8 8 Minimum flow rate Q1 l/h 3.13 3.13 3.13 3.13 3.13 3.13 5 5 5 Starting flow rate l/h 1.4 1.4 1.4 1.4 1.4 1.4 2.5 2.5 2.5 Pressure loss at Q3 bar 0.46 0.46 0.46 0.46 0.4 0.4 0.4 0.4 0.4 Pressure loss at Q4 bar 0.72 0.72 0.72 0.72 0.63 0.63 0.63 0.63 0.63 Maximum flow rate2 Qhigh m³/h 4.37 4.37 4.37 4.37 4.37 4.37 7 7 7 Flow rate at ΔP = 1 bar 3.69 3.69 3.69 3.69 3.95 3.95 5.39 5.39 5.39 2 Outlet pressure minimum 3 bars, maximum 100 hours per year, closed pipeline network
3 Please see table DIMENSIONS
Other on request -
Approval
Approval MID DE-19-MI001-PTB012 | UK/0126/0326 Dynamic range (Q3/Q1) R Up to R=800 Standards ISO 4064 | EN 14154 | OIML R49 Sanitary conformity ACS | WRAS | DM174 | BELGAQUA | KTW / W270 -
Dynamic Range (R=Q3/Q1)
Q3 2.5 m³/h - T30 / T50 R 800 Q3 2.5 m³/h - T70 / T90 R 800H / 400V Q3 4 m³/h - T30 R 800 Q3 4 m³/h - T50 / T70 / T90 R 800H / 400V H=horizontal installation position / V=vertical installation position
Other values on request -
Dimensions
Nominal diameter DN mm 15 153 15 15 20 20 20 20 20 Permanent flow rate Q3 m3/h 2.5 2.5 2.5 2.5 2.5 2.5 4 4 4 Overall length L mm 110 115 165 170 130 190 130 165 190 Counter length L1 mm 89 89 89 89 89 89 89 89 89 Counter width B mm 89 89 89 89 89 89 89 89 89 Overall length with coupling L2 mm 190 195 245 250 230 290 230 295 290 Connection thread on meter Inch G¾B G¾B G¾B G¾B G1B G1B G1B G1B G1B Connection thread of coupling Inch R½ R½ R½ R½ R¾ R¾ R¾ R1 R¾ Height H1 mm 71 71 71 71 74 74 74 74 74 Weight without coupling (approx.) kg 0.7 0.7 0.8 0.8 0.8 0.9 0.8 1.0 0.9 Weight with coupling (approx.) kg 1.1 1.1 1.2 1.2 1.2 1.3 1.2 1.6 1.3 Height H mm 18 18 18 18 21 21 21 27 21 3 Further version with connection thread on meter inlet G7/8B and meter outlet G3/4B on request -
Pressure loss graph / Typical error graph
-
Technical Data
Nominal diameter DN mm 25 25 50 50 50 50 Permanent flow rate Q3 m3/h 6.3 10 16 16 25 25 Overall length L mm 260 260 270 300 270 300 Dynamic (Q3/Q1) R 400 800 250 250 400 400 Overload flow rate Q4 m3/h 7.87 12.5 20 20 31.25 31.25 Transitional flow rate Q2 l/h 25.2 20 102 102 100 100 Minimum flow rate Q1 l/h 15.8 12.5 64 64 62.5 62.5 Starting flow rate l/h 5 5 25 25 25 25 Pressure loss at Q3 bar 0.22 0.54 0.1 0.1 0.25 0.25 Pressure loss at Q4 bar 0.34 0.84 0.19 0.19 0.45 0.45 Maximum flow rate2 Qhigh m³/h 11.02 17.5 32.13 32.13 32.13 32.13 Flow rate at ΔP = 1 bar 13.43 13.43 46.0 46.0 46.0 46.0 2 Outlet pressure minimum 3 bars, maximum 100 hours per year, closed pipeline network
Other on request -
Approval
Approval MID DE-19-MI001-PTB012 | UK/0126/0326 Dynamic range (Q3/Q1) R Up to R=800 Standards EN 4064, EN 14154, OIML R49 Sanitary conformity ACS | WRAS | DM174 | BELGAQUA | KTW / W270 -
Dynamic Range (R=Q3/Q1)
Q3 6.3 m³/h - T30 R 400 Q3 6.3 m³/h - T50 / T70 / T90 R 400H / 250V Q3 10 m³/h - T30 R 800 Q3 10 m³/h - T50 / T70 / T90 R 800H / 400V Q3 16 m³/h - T30 R 800 Q3 16 m³/h - T50 / T70 / T90 R 800H / 400V Q3 16 m³/h - DN 50 - T30 / T50 / T70 / T90 R 250 Q3 25 m³/h - DN 50 - T30 / T50 / T70 / T90 R 400 H=horizontal installation position / V=vertical installation position -
Dimensions
Nominal diameter DN mm 25 25 50 50 50 50 Permanent flow rate Q3 m3/h 6.3 10 16 16 25 25 Overall length L mm 260 260 270 300 270 300 Counter length L1 mm 89 89 92 92 92 92 Counter width B mm 89 89 94 94 94 94 DIMENSIONS - THREAD . . . . . . Overall length with coupling L2 mm 380 380 390 420 390 420 Connection thread on meter Inch G1¼B G1¼B G2½B G2½B G2½B G2½B Connection thread of coupling Inch R1 R1 R2 R2 R2 R2 Height H1 mm 78 78 90 90 90 90 Weight without coupling (approx.) kg 1.4 1.4 3.9 4.05 3.9 4.05 Weight with coupling (approx.) kg 2.0 2.0 5.5 5.65 5.5 5.65 Height H mm 27 27 41 41 41 41 DIMENSIONS - FLANGE . . . . . . Flange diameter D mm 115 115 - - - - Hole circle diameter K mm 85 85 - - - - Number of screwholes pcs 4 4 - - - - Screwhole diameter D1 mm 14 14 - - - - Height H mm 50 50 - - - - Height H1 mm 84 84 - - - - Width F mm 100 100 - - - - Weight with flanges (approx.) kg 3.4 3.4 - - - - -
Pressure loss graph / Typical error graph