ALTAIR V4 DN25/32/40
VOLUMETRIC METER
ALTAIR V4 represents the latest generation of volumetric meters developed within the framework of the MID and European standards to meet field requirements.
ALTAIR V4 is a particularly compact and robust meter, adapting to the most restrictive environments and compatible with varying water qualities.
Modular, ALTAIR V4 may be fitted at any time with an IZAR clip-on module converting it into a communicating meter, ready for mobile or fixed network (radio/wired) reading.
- DN25/32/40
- Q3=6.3 m3/h (DN25/32) and Q3=16 m3/h (DN40)
- MID approval up to R=800 (DN25/32) and R=1,000 (DN40)
- Starting flow rate at 1 l/h (DN25/32) and 4 l/h (DN40)
- Brass body
- Glass-copper register
- Compact
- Installation in any position
-
Metrological data
Nominal diameter DN mm 25 32 40 Length* L mm 260 260 300 Nominal flow rate Q3 m3/h 6.3 6.3 16 R standard* Q3/Q1 160 160 160 Starting flow rate l/h 1 1 4 Minimum flow rate* Q1 l/h 39.375 39.375 100 Transition flow rate* Q2 l/h 63 63 160 Maximum flow rate Q4 m³/h 7.875 7.875 20 Head loss at Q3 bar 0.616 0.611 0.630 Head loss at Q4 bar 0.962 0.955 0.984 Kvs (deltaP=Q²/Kvs²) 8.03 8.06 20.16 * Other values on request. -
Approval
MID approval LNE-6250 | Type A2 Standards EN 14154 | ISO 4064 | OIML R49 Sanitary conformity ACS | Belgaqua | KTW | WRAS | DM 174 -
REACH
Information pursuant to Article 33 (1) of Regulation (EC) No 1907/2006 of the European Parliament and of the Council of 18 December 2006:
This product series contains articles with the following substances in a concentration of more than 0.1% weight by weight (w/w):
- Lead -
Temperatures and pressure
Water temperature °C 0.1 ... +50 Ambient operating temperature °C +1 ... +55 Storage temperature °C -10 ... +55 Nominal pressure PN bar 16 - Dimensions
- Precision curve
-
Options
- Non-return valve
- Pair of connectors