CORONA MCI 108
MULTI-JET METER | WET RUNNER
Domestic water meter
- Modular multi-jet domestic capsule meter with inductive scanning (without magnetic influence)
- System capability, with standard applicable pulse output 1 l/pulse (inductive). CORONA MCI can be externed in any way - with IZAR RADIO COMPACT 868 I (radio module) or IZAR PULSE I (pulse transmitter)
- Only the complete measuring insert needs to be replaced regularly at the end of the calibration period - the meter housing remains fitted in the pipeline
- With composite screw head. Advantage: lower adhesion, no deposit, lower weight
- For easier reading, the zero point of the dial can be adapted to the direction of flow by turning the measuring capsule 90° to either side during installation
- A DIN DVGW-approved non-return valve can be installed in the meter housing as option
- Mounting position - housing horizontal: horizontal (R 40 - 160) and vertical (R 40)
- Mounting position - housing rising pipe: vertical (R 40 - 160)
-
General
Medium temperature range °C 1 ... 30 Temperature safety °C 1 ... 50 Ambient operating temperature °C 1 ... 55 Ambient storage temperature °C 1 ... 55 Nominal pressure PN bar 16 Display range 0.05 l ... 99,999 m³ Pulse value l/pulse 1 Approval MID TH 8629 Protection class IP 68 -
Technical data
Nominal diameter DN mm 15 20 Permanent flow rate Q3 m³/h 2.5 4 Overload flow rate Q4 m³/h 3.125 5 Transitional flow rate Q2 l/h 40 40 Minimum flow rate Q1 l/h 252 253 Starting flow rate l/h 4 6 Dynamic range horizontal installation (Q3/Q1) R 40 / 80 / 100 40 / 80 / 100 / 160 Dynamic range vertical installation (Q3/Q1) R - 40 Dynamic range (Q3/Q1) R Dynamic range (Q2/Q1) 1.6 1.6 Pressure loss at Q3 bar 0.45 0.6 Flow rate at 1 bar pressure loss1 m³/h 3.3 6.5 1 without non-return valve
2 based on R 100
3 based on R 160 -
Dimensions
Nominal diameter DN mm 15 20 Permanent flow rate Q3 m³/h 2.5 4 Overall length (DIN ISO 4064) L mm 165 / 170 190 Overall length with coupling L2 mm 245 288 Connection thread on meter (ISO 228/1) Inch G¾B G1B Connection thread of coupling (DIN 2999) Inch R½ R¾ Height H mm 22 22 Height H1 mm 117 117 Height to remove measuring insert mm 200 200 Diameter Ø B mm 95 95 Width A mm - Weight without coupling kg 1.15 1.2 Weight with coupling kg 1.4 1.6 - Pressure loss graph / Typical error graph
-
General
Medium temperature range °C 1 ... 30 Temperature safety °C 1 ... 50 Ambient operating temperature °C 1 ... 55 Ambient storage temperature °C 1 ... 55 Nominal pressure PN bar 16 Display range 0.05 l ... 99.999 m³ Pulse value l/pulse 1 Approval MID TH 8629 Protection class IP 68 -
Technical data
Nominal diameter DN mm 20 Permanent flow rate Q3 m³/h 4 Overload flow rate Q4 m³/h 5 Transitional flow rate Q2 l/h 40 Minimum flow rate Q1 l/h 252 Starting flow rate l/h 6 Dynamic range horizontal installation (Q3/Q1) R Dynamic range vertical installation (Q3/Q1) R Dynamic range (Q3/Q1) R 40 / 80 / 100 / 160 Dynamic range (Q2/Q1) 1.6 Pressure loss at Q3 bar 0.6 Flow rate at 1 bar pressure loss1 m³/h 5.8 1 without non-return valve
2 based on R 160 -
Dimensions
Nominal diameter DN mm 20 Permanent flow rate Q3 m³/h 4 Overall length (DIN ISO 4064) L mm 105 Overall length with coupling L2 mm 203 Connection thread on meter (ISO 228/1) Inch G1B Connection thread of coupling (DIN 2999) Inch R¾ Height H mm 27 Height H1 mm 145 Height to remove measuring insert mm 200 Diameter Ø B mm 95 Width A mm 95 Weight without coupling kg 1.6 Weight with coupling kg 2 - Pressure loss graph / Typical error graph