AQUILA V3 DIN

AQUILA V3 DIN

SINGLE-JET METER

AQUILA V3 DIN is a bulk meter designed for network metering and invoicing substantial quantities of cold water.
It is characterized by its very high measuring dynamics, insensitivity to disturbance and easy maintenance.
AQUILA V3 DIN is modular and can be fitted with IZAR radio or the pulse emitter IZAR PULSE, gateway to other systems. It has a CE certificate (MID) and complies with the EN 14154, OIML R49 and ISO 4054 standards in the horizontal position. Its metrological performances outstand the Regulations requirements for high and low flow rates alike.

  • Single jet meter
  • MID approval up to R 315
  • Starting flow rate DN 50: 15 l/h
  • Pulse rate 10 l/pulse
  • High dynamic range
  • Glass/metal register as standard
  • Cast iron body
  • Technical data
    Nominal diameterDNmm5080100
    Permanent flow rateQ3m³/h2563100
    Dynamic range (Q3/Q1)1R315315315
    Starting flow ratel/h154045
    Minimum flow rateQ1l/h80200317
    Transitional flow rateQ2l/h127320508
    Overload flow rateQ4m³/h31.2578.75125
    Overloadm³/h40100150
    Pulse ratel/pulse101010
    1 other values on request
  • Approval
    MIDLNE - 26943
    Potable waterACS
  • Temperature and pressure
    Medium temperature range°C1 ... 50
    Nominal pressurePNbar16
    Breaking pressurePNbar62
    Ambient limit temperature / storage°C-20 ... +70
  • Dimensions
    Nominal diameterDNmm5080100
    LengthLmm270300360
    Widthwmm110163155
    WidthWmm193263265
    HeightHmm177218230
    Heighth1mm7095105
    Weightkg12.52128
    Flange diameterDmm165200220
  • Precision curve
  • Pressure loss (delta P = Q²/Kvs²)
    Nominal diameterDNmm5080100
    kvs3695130
    This technology doesn't require straight length