AQUARIUS S / RS / P

SINGLE-JET METER
AQUARIUS S / RS / P
water Water » Single-Jet Meter | Datasheet

Application:

For measuring consumption in apartments and buildings for billing purposes


Features:

  • Single-jet impeller meter of fully dry-running design with magnetic coupling
  • Modularity with the HYDROMETER system world
  • Excellent starting flow rate
  • Low pressure loss
  • Installation position: horizontal, vertical, riser pipe, downpipe
  • Compact design
  • Rotatable counter
  • Shield against static magnetic fields according to VDDW standard and EN 14154
  • Working pressure 10 bar according to DIN 2401
  • Protection class IP 54


General

Note:
HYDROMETER single-jet impeller meters are delivered calibrated in accordance with the calibration regulations. (AQUARIUS P with 10 l/pulse cannot be calibrated.)
Note:
AQUARIUS S: radio segment IZAR RS 868 or 434 MHz retrofittable
AQUARIUS RS: with mounted and configured radio segment IZAR RS 868 or 434 MHz
AQUARIUS P: pulse output by reed switch, cable length 2 m LiYY 2 x 0.25 mm², contact rating 24 V ~ 0.2 A, max. cable length 20 - 50 m (depending on electrical perturbation). Switching amplifier have to be used at a longer distance.

AQUARIUS S / RS / P
Medium temperature range cold water °C 0 ... 30
Medium temperature range warm water °C 0 ... 90
Nominal pressure PN bar 10
Display range 0.1 l ... 9,999 m³/h
EC type approval EO 6 30 °C D 98 / 6.131.09
EC type approval EO 6 90 °C D 98 / 6.331.93
Metrological class A/B•H
Protection class IP 54

Versions

AQUARIUS S
AQUARIUS S
AQUARIUS RS
AQUARIUS RS
AQUARIUS P
AQUARIUS P
Note:
HYDROMETER single-jet impeller meters are delivered calibrated in accordance with the calibration regulations. (AQUARIUS P with 10 l/pulse cannot be calibrated.)
Note:
AQUARIUS S: radio segment IZAR RS 868 or 434 MHz retrofittable
AQUARIUS RS: with mounted and configured radio segment IZAR RS 868 or 434 MHz
AQUARIUS P: pulse output by reed switch, cable length 2 m LiYY 2 x 0.25 mm², contact rating 24 V ~ 0.2 A, max. cable length 20 - 50 m (depending on electrical perturbation). Switching amplifier have to be used at a longer distance.

Nominal flow rate Qn m³/h 1.5 1.5 1.5 2.5
Overall length L mm 80 110 130 130
AQUARIUS S - radio segment retrofittable
AQUARIUS RS - radio segment mounted
AQUARIUS P - pulse output l/pulse 10 / 100 10 / 100 - 10 / 100

Technical data

Note:
HYDROMETER single-jet impeller meters are delivered calibrated in accordance with the calibration regulations. (AQUARIUS P with 10 l/pulse cannot be calibrated.)
Note:
AQUARIUS S: radio segment IZAR RS 868 or 434 MHz retrofittable
AQUARIUS RS: with mounted and configured radio segment IZAR RS 868 or 434 MHz
AQUARIUS P: pulse output by reed switch, cable length 2 m LiYY 2 x 0.25 mm², contact rating 24 V ~ 0.2 A, max. cable length 20 - 50 m (depending on electrical perturbation). Switching amplifier have to be used at a longer distance.

Nominal flow rate Qn m³/h 1.5 1.5 1.5 2.5
Overall length L mm 80 110 130 130
Nominal diameter DN mm 15 15 15 20
Maximum flow rate (short-term) Qmax m³/h 3 3 3 5
Transition flow rate horizontal Qt l/h 120 120 120 200
Transition flow rate any position Qt l/h 150 150 150 250
Minimum flow rate horizontal Qmin l/h 30 30 30 50
Minimum flow rate any position Qmin l/h 60 60 60 100
Starting flow rate horizontal l/h 8 8 8 12
Starting flow rate any position l/h 14 14 14 18
Pressure loss at Qn bar 0.19 0.19 0.19 0.25

Dimensions

Note:
HYDROMETER single-jet impeller meters are delivered calibrated in accordance with the calibration regulations. (AQUARIUS P with 10 l/pulse cannot be calibrated.)
Note:
AQUARIUS S: radio segment IZAR RS 868 or 434 MHz retrofittable
AQUARIUS RS: with mounted and configured radio segment IZAR RS 868 or 434 MHz
AQUARIUS P: pulse output by reed switch, cable length 2 m LiYY 2 x 0.25 mm², contact rating 24 V ~ 0.2 A, max. cable length 20 - 50 m (depending on electrical perturbation). Switching amplifier have to be used at a longer distance.

Nominal flow rate Qn m³/h 1.5 1.5 1.5 2.5
Overall length L mm 80 110 130 130
Overall length with coupling L2 mm 160 190 210 228
Overall length with tap coupling L2 mm 138 168 188 -
Connection thread on meter Inch G¾B G¾B G¾B G1B
Connection thread of coupling Inch
Height H mm 14 14 14 17
Height (AQUARIUS S / P) H1 mm 52 52 52 52
Height (AQUARIUS RS) H1 mm 69 69 69 69
Diameter Ø B mm 64 64 64 64
Weight without coupling kg 0.4 0.44 0.54 0.54
Weight with coupling kg 0.58 0.64 0.72 0.72

Pressure loss graph / Typical error graph

Pressore loss graph
Pressore loss graph
Typical error graph
Typical error graph