SINGLE-JET METER
Water
»
Single-Jet Meter
|
Datasheet
Application:
For measuring consumption in apartments and buildings for billing purposes
Features:
- Single-jet impeller meter of fully dry-running design with magnetic coupling
- Modularity with the HYDROMETER system world
- Excellent starting flow rate
- Low pressure loss
- Installation position: horizontal, vertical, riser pipe, downpipe
- Compact design
- Rotatable counter
- Shield against static magnetic fields according to VDDW standard and EN 14154
- Working pressure 10 bar according to DIN 2401
- Protection class IP 54
Note:
HYDROMETER single-jet impeller meters are delivered calibrated in accordance with the calibration regulations. (AQUARIUS P with 10 l/pulse cannot be calibrated.)
Note:
AQUARIUS S: radio segment IZAR RS 868 or 434 MHz retrofittable
AQUARIUS RS: with mounted and configured radio segment IZAR RS 868 or 434 MHz
AQUARIUS P: pulse output by reed switch, cable length 2 m LiYY 2 x 0.25 mm², contact rating 24 V ~ 0.2 A, max. cable length 20 - 50 m (depending on electrical perturbation). Switching amplifier have to be used at a longer distance.
|
|
|
AQUARIUS S / RS / P |
| Medium temperature range cold water |
|
°C |
0 ... 30 |
| Medium temperature range warm water |
|
°C |
0 ... 90 |
| Nominal pressure |
PN |
bar |
10 |
| Display range |
|
|
0.1 l ... 9,999 m³/h |
| EC type approval EO 6 30 °C |
|
|
D 98 / 6.131.09 |
| EC type approval EO 6 90 °C |
|
|
D 98 / 6.331.93 |
| Metrological class |
|
|
A/B•H |
| Protection class |
|
|
IP 54 |
-
- AQUARIUS S
-
- AQUARIUS RS
-
- AQUARIUS P
Note:
HYDROMETER single-jet impeller meters are delivered calibrated in accordance with the calibration regulations. (AQUARIUS P with 10 l/pulse cannot be calibrated.)
Note:
AQUARIUS S: radio segment IZAR RS 868 or 434 MHz retrofittable
AQUARIUS RS: with mounted and configured radio segment IZAR RS 868 or 434 MHz
AQUARIUS P: pulse output by reed switch, cable length 2 m LiYY 2 x 0.25 mm², contact rating 24 V ~ 0.2 A, max. cable length 20 - 50 m (depending on electrical perturbation). Switching amplifier have to be used at a longer distance.
| Nominal flow rate |
Qn |
m³/h |
1.5 |
1.5 |
1.5 |
2.5 |
| Overall length |
L |
mm |
80 |
110 |
130 |
130 |
| AQUARIUS S - radio segment retrofittable |
|
|
• |
• |
• |
• |
| AQUARIUS RS - radio segment mounted |
|
|
• |
• |
• |
• |
| AQUARIUS P - pulse output |
|
l/pulse |
10 / 100 |
10 / 100 |
- |
10 / 100 |
Note:
HYDROMETER single-jet impeller meters are delivered calibrated in accordance with the calibration regulations. (AQUARIUS P with 10 l/pulse cannot be calibrated.)
Note:
AQUARIUS S: radio segment IZAR RS 868 or 434 MHz retrofittable
AQUARIUS RS: with mounted and configured radio segment IZAR RS 868 or 434 MHz
AQUARIUS P: pulse output by reed switch, cable length 2 m LiYY 2 x 0.25 mm², contact rating 24 V ~ 0.2 A, max. cable length 20 - 50 m (depending on electrical perturbation). Switching amplifier have to be used at a longer distance.
| Nominal flow rate |
Qn |
m³/h |
1.5 |
1.5 |
1.5 |
2.5 |
| Overall length |
L |
mm |
80 |
110 |
130 |
130 |
| Nominal diameter |
DN |
mm |
15 |
15 |
15 |
20 |
| Maximum flow rate (short-term) |
Qmax |
m³/h |
3 |
3 |
3 |
5 |
| Transition flow rate horizontal |
Qt |
l/h |
120 |
120 |
120 |
200 |
| Transition flow rate any position |
Qt |
l/h |
150 |
150 |
150 |
250 |
| Minimum flow rate horizontal |
Qmin |
l/h |
30 |
30 |
30 |
50 |
| Minimum flow rate any position |
Qmin |
l/h |
60 |
60 |
60 |
100 |
| Starting flow rate horizontal |
|
l/h |
8 |
8 |
8 |
12 |
| Starting flow rate any position |
|
l/h |
14 |
14 |
14 |
18 |
| Pressure loss at Qn |
|
bar |
0.19 |
0.19 |
0.19 |
0.25 |
-
-
Note:
HYDROMETER single-jet impeller meters are delivered calibrated in accordance with the calibration regulations. (AQUARIUS P with 10 l/pulse cannot be calibrated.)
Note:
AQUARIUS S: radio segment IZAR RS 868 or 434 MHz retrofittable
AQUARIUS RS: with mounted and configured radio segment IZAR RS 868 or 434 MHz
AQUARIUS P: pulse output by reed switch, cable length 2 m LiYY 2 x 0.25 mm², contact rating 24 V ~ 0.2 A, max. cable length 20 - 50 m (depending on electrical perturbation). Switching amplifier have to be used at a longer distance.
| Nominal flow rate |
Qn |
m³/h |
1.5 |
1.5 |
1.5 |
2.5 |
| Overall length |
L |
mm |
80 |
110 |
130 |
130 |
| Overall length with coupling |
L2 |
mm |
160 |
190 |
210 |
228 |
| Overall length with tap coupling |
L2 |
mm |
138 |
168 |
188 |
- |
| Connection thread on meter |
|
Inch |
G¾B |
G¾B |
G¾B |
G1B |
| Connection thread of coupling |
|
Inch |
R½ |
R½ |
R½ |
R¾ |
| Height |
H |
mm |
14 |
14 |
14 |
17 |
| Height (AQUARIUS S / P) |
H1 |
mm |
52 |
52 |
52 |
52 |
| Height (AQUARIUS RS) |
H1 |
mm |
69 |
69 |
69 |
69 |
| Diameter |
Ø B |
mm |
64 |
64 |
64 |
64 |
| Weight without coupling |
|
kg |
0.4 |
0.44 |
0.54 |
0.54 |
| Weight with coupling |
|
kg |
0.58 |
0.64 |
0.72 |
0.72 |
-
- Pressore loss graph
-
- Typical error graph
Back to: SINGLE-JET METER