Single-Jet Meter
Water
»
Single-Jet Meter
|
|
Datasheet
Application:
AQUARIUS is a domestic water meter designed for measuring consumption of cold or hot water in housing blocks. AQUARIUS is MID approved and meets the metrology standard OIML R49, EN14154 and ISO 4064. Magnetic transmission is used to insulate the register from the hydraulic part, and the register rotates to ensure easier index reading. AQUARIUS belongs to the Sappel modular range and may be fitted, even after it is installed, with an IZAR PULSE pulse emitter, an IZAR RADIO or an IZAR DOSING device.
Features:
- Single jet meter
- Modular meter
- R80 horizontal (Approved MID up to R=100); R40 vertical
- Available in composite version (for cold water only)
- Glass/metal register in option
* other value on request
* composite version : only 0 ... 50 °C
* Other value on request
| Nominal diameter |
DN |
mm |
15 |
15 |
15 |
20 |
| Length |
L |
mm |
80 |
110 |
115 |
130 |
| Housing Brass/Composite |
|
|
Brass |
Brass/Comp |
Brass/Comp |
Brass |
| Nominal flowrate |
Q3 |
m³/h |
2.5 |
2.5 |
2.5 |
4 |
| R* |
(Q3/Q1) |
|
80 |
80 |
80 |
80 |
| Starting flowrate |
|
l/h |
12 |
12 |
12 |
17 |
| Min. flowrate |
Q1 |
l/h |
31 |
31 |
31 |
50 |
| Transition flowrate |
Q2 |
l/h |
50 |
50 |
50 |
80 |
| Max. flowrate |
Q4 |
m³/h |
3.125 |
3.125 |
3.125 |
5 |
* other value on request
* composite version : only 0 ... 50 °C
* Other value on request
|
AQUARIUS |
| MID approval |
LNE 6904 |
| Alimentarity |
ACS |
* other value on request
* composite version : only 0 ... 50 °C
* Other value on request
|
|
AQUARIUS |
| Medium temperature range* |
°C |
0...50 / 0...90 |
| Nominal pressure |
bar |
16 |
* other value on request
* composite version : only 0 ... 50 °C
* Other value on request
| Nominal diameter |
DN |
mm |
15 |
15 |
15 |
20 |
| Length |
L |
mm |
80 |
110 |
115 |
130 |
| Housing Brass/Composite |
|
|
Brass |
Brass/Comp |
Brass/Comp |
Brass |
| Width |
B |
mm |
90 |
90 |
90 |
90 |
| Total height |
H |
mm |
77 |
72 |
72 |
74 |
| Thread connections |
G |
inch |
3/4" |
3/4" |
3/4" (*) |
1" |
| Weight |
|
Kg |
0.46 |
0.53/0.2 |
0.53/0.2 |
0.58 |
* other value on request
* composite version : only 0 ... 50 °C
* Other value on request
| Nominal diameter |
DN |
mm |
15 |
15 |
15 |
20 |
| Length |
L |
mm |
80 |
110 |
115 |
130 |
| Housing Brass/Composite |
|
|
Brass |
Brass/Comp |
Brass/Comp |
Brass |
| kvs (deltaP=Q²/Kvs²) |
|
|
3.12 |
3.12 |
3.12 |
5 |
The technology doesn't require straight length.
Back to: Single-Jet Meter