CORONA MWI 109

Multi-Jet Meter | Wet Runner
CORONA MWI 109
water Water » Wet Runner |
| Datasheet

Application:

Domestic water meter


Features:
  • Modular multi-jet domestic meter with inductive scanning (without magnetic influence)
  • System capability, with standard applicable pulse output 1 l/pulse (inductive). CORONA MWI can be externed in any way - with IZAR RADIO COMPACT 868 I (radio module) or IZAR PULSE I (pulse transmitter)
  • Extremely low pressure loss and considerably extended measuring range
  • Records very small amounts of water consumption
  • Maximum long-term accuracy and absolutely corrosion-resistant
  • Measuring data better than specified by calibration regulations
  • Strainer insert in inlet connection for cleaning without damaging the seal
  • Capable of withstanding any load for a short time
  • Fine adjustment by regulating plug


General

Meter for horizontal pipes
Medium temperature range °C 0 ... 30
Temperature safety °C 0 ... 50
Ambient operating temperature °C 0 ... 55
Ambient storage temperature °C 0 ... 55
Nominal pressure PN bar 16
Display range 0.05 l ... 99,999 m³
Pulse value l/pulse 1
Protection class IP 68

Technical data

Nominal diameter DN mm 15 20 25
Permanent flow rate Q3 m³/h 2.5 4 4
Overload flow rate Q4 m³/h 3.125 5 5
Transitional flow rate Q2 l/h 40 40 40
Minimum flow rate Q1 l/h 25* 25** 25**
Starting flow rate l/h 4 4 6
Pressure loss at Q3 bar 0.36 0.47 0.6
Flow rate at 1 bar pressure loss m³/h 4.19 5.85 6.5

Approval

Nominal diameter DN mm 15 20 25
Permanent flow rate Q3 m³/h 2.5 4 4
MID TH 8627 TH 8627 TH 8627
Dynamic range horizontal installation (Q3/Q1) R 40 / 80 / 100 40 / 80 / 100 / 160 40 / 80 / 100 / 160
Dynamic range vertical installation (Q3/Q1) R 40 40 40

Dimensions

Nominal diameter DN mm 15 20 25
Permanent flow rate Q3 m³/h 2.5 4 4
Overall length (DIN ISO 4064) L mm 165 / 170 190 175
Overall length with coupling L2 mm 245 288 295
Connection thread on meter (ISO 228/1) Inch G¾B G1B G1¼B
Connection thread of coupling (DIN 2999) Inch R1
Height H mm 33 37 22
Height H1 mm 73 73 117
Diameter Ø B mm 95 95 95
Weight without coupling kg 1.3 1.4 1.5
Weight with coupling kg 1.5 1.7 1.8

Pressure loss graph / Typical error graph

Pressure loss graph
Pressure loss graph
Typical error graph
Typical error graph

General

Meter for rising pipes
Medium temperature range °C 0 ... 30
Temperature safety °C 0 ... 50
Ambient operating temperature °C 0 ... 55
Ambient storage temperature °C 0 ... 55
Nominal pressure PN bar 16
Display range 0.05 l ... 99,999 m³
Pulse value l/pulse 1
Protection class IP 68

Technical data

Nominal diameter DN mm 20
Permanent flow rate Q3 m³/h 4
Overload flow rate Q4 m³/h 5
Transitional flow rate Q2 l/h 40
Minimum flow rate Q1 l/h 25
Starting flow rate l/h 4
Pressure loss at Q3 bar 0.52
Flow rate at 1 bar pressure loss m³/h 5.56

Approval

Nominal diameter DN mm 20
Permanent flow rate Q3 m³/h 4
MID TH 8627
Dynamic range vertical installation (Q3/Q1) R 40 / 80 / 100 / 160

Dimensions

Nominal diameter DN mm 20
Permanent flow rate Q3 m³/h 4
Overall length (DIN ISO 4064) L mm 105
Overall length with coupling L2 mm 203
Connection thread on meter (ISO 228/1) Inch G1B
Connection thread of coupling (DIN 2999) Inch
Height H mm 18
Height H1 mm 108
Diameter Ø B mm 95
Width A mm 82
Weight without coupling kg 1.7
Weight with coupling kg 2.0

Pressure loss graph / Typical error graph

Pressure loss graph
Pressure loss graph
Typical error graph
Typical error graph