Domestic water meter
Meter for horizontal pipes | |||
---|---|---|---|
Medium temperature range | °C | 0 ... 30 | |
Temperature safety | °C | 0 ... 50 | |
Ambient operating temperature | °C | 0 ... 55 | |
Ambient storage temperature | °C | 0 ... 55 | |
Nominal pressure | PN | bar | 16 |
Display range | 0.05 l ... 99,999 m³ | ||
Pulse value | l/pulse | 1 | |
Approval | MID TH 8629 | ||
Protection class | IP 68 |
Nominal diameter | DN | mm | 15 | 20 |
---|---|---|---|---|
Permanent flow rate | Q3 | m³/h | 2.5 | 4 |
Overload flow rate | Q4 | m³/h | 3.125 | 5 |
Transitional flow rate | Q2 | l/h | 40 | 40 |
Minimum flow rate | Q1 | l/h | 25** | 25*** |
Starting flow rate | l/h | 4 | 6 | |
Dynamic range horizontal installation (Q3/Q1) | R | 40 / 80 / 100 | 40 / 80 / 100 / 160 | |
Dynamic range vertical installation (Q3/Q1) | R | - | 40 | |
Dynamic range (Q2/Q1) | 1.6 | 1.6 | ||
Pressure loss at Q3 | bar | 0.45 | 0.6 | |
Flow rate at 1 bar pressure loss* | m³/h | 3.3 | 6.5 |
Nominal diameter | DN | mm | 15 | 20 |
---|---|---|---|---|
Permanent flow rate | Q3 | m³/h | 2.5 | 4 |
Overall length (DIN ISO 4064) | L | mm | 165 / 170 | 190 |
Overall length with coupling | L2 | mm | 245 | 288 |
Connection thread on meter (ISO 228/1) | Inch | G¾B | G1B | |
Connection thread of coupling (DIN 2999) | Inch | R½ | R¾ | |
Height | H | mm | 22 | 22 |
Height | H1 | mm | 117 | 117 |
Height to remove measuring insert | mm | 200 | 200 | |
Diameter | Ø B | mm | 95 | 95 |
Width | A | mm | - | |
Weight without coupling | kg | 1.15 | 1.2 | |
Weight with coupling | kg | 1.4 | 1.6 |
Meter for rising pipes | |||
---|---|---|---|
Medium temperature range | °C | 0 ... 30 | |
Temperature safety | °C | 0 ... 50 | |
Ambient operating temperature | °C | 0 ... 55 | |
Ambient storage temperature | °C | 0 ... 55 | |
Nominal pressure | PN | bar | 16 |
Display range | 0.05 l ... 99.999 m³ | ||
Pulse value | l/pulse | 1 | |
Approval | MID TH 8629 | ||
Protection class | IP 68 |
Nominal diameter | DN | mm | 20 |
---|---|---|---|
Permanent flow rate | Q3 | m³/h | 4 |
Overload flow rate | Q4 | m³/h | 5 |
Transitional flow rate | Q2 | l/h | 40 |
Minimum flow rate | Q1 | l/h | 25** |
Starting flow rate | l/h | 6 | |
Dynamic range (Q3/Q1) | R | 40 / 80 / 100 / 160 | |
Dynamic range (Q2/Q1) | 1.6 | ||
Pressure loss at Q3 | bar | 0.6 | |
Flow rate at 1 bar pressure loss* | m³/h | 5.8 |
Nominal diameter | DN | mm | 20 |
---|---|---|---|
Permanent flow rate | Q3 | m³/h | 4 |
Overall length (DIN ISO 4064) | L | mm | 105 |
Overall length with coupling | L2 | mm | 203 |
Connection thread on meter (ISO 228/1) | Inch | G1B | |
Connection thread of coupling (DIN 2999) | Inch | R¾ | |
Height | H | mm | 27 |
Height | H1 | mm | 145 |
Height to remove measuring insert | mm | 200 | |
Diameter | Ø B | mm | 95 |
Width | A | mm | 95 |
Weight without coupling | kg | 1.6 | |
Weight with coupling | kg | 2 |