Application:

For measuring of fluctuating flows in the utility sector.


Features:
  • For horizontal installation
  • Outstanding long-term accuracy even under extreme loads
  • Extended measuring range better than metrological class
  • Complete head unit with counter and sensors can be rotated by 350° for easier reading
  • Encapsulated counter of glass/copper IP 68
  • Integrated measurement ouptputs as standard
  • Sensors for remote readout (digital) and flow measurement (analogue) can be retrofitted on site without affecting calibration


General

WESAN WS 233
Medium temperature range °C 1 ... 30
Temperature safety °C 1 ... 50
Ambient operating temperature °C 1 ... 55
Ambient storage temperature °C 1 ... 55
Nominal pressure PN bar 161
Protection class IP 68

Technical data

Nominal diameter DN mm 50 65 80 100 150
Permanent flow rate Q3 m³/h 25 40 63 100 250
Minimum flow rate Q1 m³/h 0.63 1 1.58 2.5 6.25
Transitional flow rate Q2 m³/h 1 1.6 2.52 4 10
Overload flow rate Q4 m³/h 31.25 50 78.75 125 312.5
Starting flow rate l/h 60 60 90 90 150
Flow rate at 0.1 bar pressure loss m³/h 13 20 32 63 125
Pressure loss at Q3 bar 0.4 0.4 0.4 0.25 0.4

Approval

Nominal diameter DN mm 50 65 80 100 150
MID (A 0445/3505/2011)
Dynamic range (Q3/Q1) R 40•H 40•H 40•H 40•H 40•H
Potable water KTW / W270 KTW / W270 KTW / W270 KTW / W270 KTW / W270

Pulse outputs

Nominal diameter DN mm 50 65 80 100 150
Reed switch 5702- pulse value 1 l/pulse 100 100 100 100 1000
Reed switch 5702- pulse value 2 l/pulse 1000 1000 1000 1000 10000
Special pulse values3 l/pulse 2.5 / 5 / 10 / 25 / 50 2.5 / 5 / 10 / 25 / 50 2.5 / 5 / 10 / 25 / 50 2.5 / 5 / 10 / 25 / 50 25 / 50 / 100 / 250 / 500
IR pulse transmitter 5732 l/pulse 1 1 1 1 10

Display range

Nominal diameter DN mm 50 65 80 100 150
0.5 l ... 999,999 m³ -
5.0 l ... 9,999,999 m³ - - - -

Dimensions

Nominal diameter DN mm 50 65 80 100 150
Overall length (DIN 19625) L mm 270 300 300 360 430 / 500
Overall length (DIN ISO 4064) L mm 300 300 350 350 500
Flange diameter D mm 165 185 200 220 285
Hole circle diameter K mm 125 145 160 180 240
Number of screwholes pcs 4 4 4 / 8 8 8
Screwhole diameter D1 mm 18 18 18 18 23
Height H mm 85 97 102 113 141
Height H1 mm 135 135 180 190 351
Height to remove measuring insert mm 240 240 330 340 620
Diameter Ø B mm 110 110 110 110 110
Meter width mm 173 173 239 239 310
Weight kg 14.5 17.7 24 28 79.5

Special versions

- Versions with different nominal pressure on request

- Flange for ANSI and BS on request

- Temperature up to 90 °C on request

- Special pulse values on request

- Special overall length on request

Pressure loss graph / Typical error graph