Anwendung:

Volume measuring component for measuring heat for billing hot water consumption.


Merkmale:

  • Multi-jet impeller meters designed to the latest technical standards with completely dry running operation and magnetic coupling
  • The roller counter is dustproof and condensation-proof and can be rotated for easier reading
  • For installation in rising pipes and downpipes
  • The built-in pulse transmitter is cast in a waterproof enclosure and is easily replaceable
  • The pulse transmitter for volume measuring components is fitted with a 100 Ω, ¼ W protective resistor (cable length 3 m)
  • Facility for remote transmission of flow rates
  • The compact design in subassemblies simplifies maintenance and repair
  • Only the impeller operates in the wet chamber to prevent faults due to sediment
  • The meters are equipped with a sealed shield for protection against magnetic interference


General

RAY FS MT | VERTICAL 415-418
Medium temperature range °C 0 ... 901/ 0 ... 1202
Nominal pressure PN bar 16
Display range 0.05 l ... 100,000 m³
Pulse value l/pulse 1 / 10 / 100 (other pulse rates on request)
Bearing Carbide or plastic
Approval National 22.16 / 82.10
Metrological class A•H
Protection class IP 65

Technical data

Nominal diameter DN mm 20 20 20 25 25 25 25 40 40
Nominal flow rate Qn m³/h 1 1.5 2.5 3.5 3.5 6 6 10 10
Overall length L mm 105 105 105 135 150 135 150 150 200
Maximum flow rate (short-term) Qmax m³/h 2 3 5 7 7 12 12 20 20
Transition flow rate Qt l/h 100 150 250 350 350 600 600 1000 1000
Minimum flow rate Qmin l/h 25 30 50 65 65 90 90 160 160
Starting flow rate l/h 10 12 19 25 25 35 35 60 60
Flow rate at 0.1 bar pressure loss1 m³/h 0.6 1 1.6 2.2 2.2 3.8 3.8 6.3 6.3
Flow rate at 0.1 bar pressure loss2 m³/h - 1.2 1.8 2.5 2.2 2.4 2.4 6.3 6.3
Flow resistance coefficient Zeta 72.4 26.1 10.2 13.1 13.1 4.4 4.4 10.5 10.5

Dimensions

Nominal diameter DN mm 20 20 20 25 25 25 25 40 40
Nominal flow rate Qn m³/h 1 1.5 2.5 3.5 3.5 6 6 10 10
Overall length L mm 105 105 105 135 150 135 150 150 200
Connection thread on meter Inch G1B G1B G1B G1¼B G1¼B G1¼B G1¼B G2B G2B
Connection thread of coupling Inch R1 R1 R1 R1 R1½ R1½
Height H mm 14 14 14 31 31 31 31 21 21
Height H1 mm 180 180 180 191 191 191 191 221 221
Diameter Ø B mm 96 96 96 102 102 102 102 130 130
Width A mm 82 82 82 95 95 95 95 120 120
Weight without coupling kg 2.2 2.1 2.1 3.1 3.1 3.1 3.1 5.5 5.5
Weight with coupling kg 2.5 2.4 2.4 3.7 3.7 3.7 3.7 6.7 6.7

Note

When using the contact water meters as volume measuring component, we recommend that the meters are selected so that the pressure loss of 0.1 bar is not exceeded at maximum load.

Order the pulse output without resistor for a low-resistance load, e.g. mechanical roller counters.

Pressure loss graph

Rising pipe
Rising pipe
Downpipe
Downpipe

Typical error graph

Typical error graph
Typical error graph